Current activity of Russia in measurement assurance of Earth optical observations

被引:7
作者
Sapritsky, V. I. [1 ]
Krutikov, V. N. [2 ]
Ivanov, V. S. [1 ]
Panfilov, A. S. [1 ]
Pavlovich, M. N. [1 ]
Burdakin, A. A. [1 ]
Rakov, V. V. [1 ]
Morozova, S. P. [1 ]
Lisyansky, B. E. [1 ]
Khlevnoy, B. B. [1 ]
Gavrilov, V. R. [1 ]
Ogarev, S. A. [1 ]
Pusanov, A. V. [1 ]
Samoylov, M. L. [1 ]
Solodilov, M. V. [1 ]
Katysheva, A. A. [1 ]
Parfentyev, N. A. [1 ]
Stakharny, A. A. [1 ]
机构
[1] All Russian Res Inst Opt & Phys Measurements VNII, Moscow, Russia
[2] Fed Agcy Tech Regulating & Metrol, Moscow, Russia
关键词
CALIBRATION;
D O I
10.1088/0026-1394/49/2/S9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The All-Russian Research Institute for Optical and Physical Measurements is currently carrying out a project on developing an integrated system for measurement assurance of Earth observations. The system should provide ground calibration of instruments and their control during space-borne observations. Such tasks require appropriate measurement facilities as well as regulatory documentation. In this paper we discuss the newly created radiometric facility, traceable to SI standard, for precise calibration of instruments for Earth observations, the project on precise monitoring of the stability of the instrument's in-flight performance and the development of national regulatory documentation in harmony with the international document 'Quality Assurance Framework for Earth Observation-QA4EO'.
引用
收藏
页码:S9 / S16
页数:8
相关论文
共 10 条
  • [1] [Anonymous], GLOB EARTH OBS SYST
  • [2] Changes in the radiometric sensitivity of SeaWiFS determined from lunar and solar-based measurements
    Barnes, RA
    Eplee, RE
    Patt, FS
    McClain, CR
    [J]. APPLIED OPTICS, 1999, 38 (21) : 4649 - 4664
  • [3] Melting points of gallium and of binary eutectics with gallium realized in small cells
    Burdakin, A.
    Khlevnoy, B.
    Samoylov, M.
    Sapritsky, V.
    Ogarev, S.
    Panfilov, A.
    Bingham, G.
    Privalsky, V.
    Tansock, J.
    Humpherys, T.
    [J]. METROLOGIA, 2008, 45 (01) : 75 - 82
  • [4] The area under a curve specified by measured values
    Cox, M. G.
    [J]. METROLOGIA, 2007, 44 (05) : 365 - 378
  • [5] Best Practice Guidelines for Pre-Launch Characterization and Calibration of Instruments for Passive Optical Remote Sensing
    Datla, R. U.
    Rice, J. P.
    Lykke, K. R.
    Johnson, B. C.
    Butler, J. J.
    Xiong, X.
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2011, 116 (02): : 621 - 646
  • [6] The Global Earth Observation System of Systems (GEOSS) and metrological support for measuring radiometric properties of objects of observations
    Krutikov, VN
    Sapritsky, VI
    Khlevnoy, BB
    Lisiansky, BE
    Morozova, SP
    Ogarev, SA
    Panfilov, AS
    Sakharov, MK
    Samoylov, ML
    Bingham, G
    Humpherys, T
    Thurgood, A
    Privalsky, VE
    [J]. METROLOGIA, 2006, 43 (02) : S94 - S97
  • [7] Panfilov AS, 2010, STUDYING EARTH SPACE, V5, P87
  • [8] Trends and uncertainties in thermal calibration of AVHRR radiometers onboard NOAA-9 to NOAA-16
    Trishchenko, AP
    Fedosejevs, G
    Li, ZQ
    Cihlar, J
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2002, 107 (D24) : ACL17 - 1
  • [9] *US DEP COMM, 2004, 7047 NISTIR US DEP C
  • [10] Trending results of MODIS optics on-orbit degradation
    Xiong, XJ
    Wu, AS
    Esposito, JA
    Sun, JQ
    Che, NZ
    Guenther, B