Liquid-filled ionization chamber temperature dependence

被引:10
作者
Franco, L. [1 ]
Gomez, F. [1 ]
Iglesias, A. [1 ]
Pardo, J. [1 ]
Pazos, A. [1 ]
Pena, J. [1 ]
Zapata, M. [1 ]
机构
[1] Univ Santiago, Fac Fis, Dpto Fis Particulas, Santiago De Compostela 15782, Spain
关键词
free ion yield; temperature dependence; Onsager theory; isooctane; liquid-filled ionization chamber; absolute dosimetry;
D O I
10.1016/j.nima.2006.01.109
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Temperature and pressure corrections of the read-out signal of ionization chambers have a crucial importance in order to perform high-precision absolute dose measurements. In the present work the temperature and pressure dependences of a sealed liquid isooctane filled ionization chamber (previously developed by the authors) for radiotherapy applications have been studied. We have analyzed the thermal response of the liquid ionization chamber in a similar to 20 degrees C interval around room temperature. The temperature dependence of the signal can be considered linear, with a slope that depends on the chamber collection electric field. For example, a relative signal slope of 0.27 x 10(-2) K-1 for an operation electric field of 1.67 x 106 V m(-1) has been measured in our detector. On the other hand, ambient pressure dependence has been found negligible, as expected for liquid-filled chambers. The thermal dependence of the liquid ionization chamber signal can be parametrized within the Onsager theory on initial recombination. Considering that changes with temperature of the detector response are due to variations in the free ion yield, a parametrization of this dependence has been obtained. There is a good agreement between the experimental data and the theoretical model from the Onsager framework. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:584 / 588
页数:5
相关论文
共 10 条
[1]  
[Anonymous], 2003, CRC Handbook of Chemistry and Physics, V84th
[2]   Long-term stability of liquid ionization chambers with regard to their qualification as local reference dosimeters for low dose-rate absorbed dose measurements in water [J].
Bahar-Gogani, J ;
Grindborg, JE ;
Johansson, BE ;
Wickman, G .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03) :729-740
[3]   A 128 pixel linear array for radiotherapy quality assurance [J].
Franco, L ;
Gómez, F ;
Iglesias, A ;
Lobato, R ;
Marín, J ;
Mosquera, J ;
Pardo, J ;
Pazos, A ;
Pena, J ;
Pombar, M ;
Rodríguez, A ;
Saavedra, D ;
Sendón, J ;
Yañez, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 535 (1-2) :98-101
[4]   SATURATION CHARACTERISTICS OF PARALLEL-PLATE IONIZATION CHAMBERS [J].
GREENING, JR .
PHYSICS IN MEDICINE AND BIOLOGY, 1964, 9 (02) :143-&
[5]   Initial recombination of ions [J].
Onsager, L .
PHYSICAL REVIEW, 1938, 54 (08) :554-557
[6]   Free ion yield observed in liquid isooctane irradiated by γ rays.: Comparison with the Onsager theory [J].
Pardo, J ;
Franco, L ;
Gómez, F ;
Iglesias, A ;
Lobato, R ;
Mosquera, J ;
Pazos, A ;
Pena, J ;
Pombar, M ;
Rodríguez, A ;
Sendón, J .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (10) :1905-1914
[7]   Development and operation of a pixel segmented liquid-filled linear array for radiotherapy quality assurance [J].
Pardo, J ;
Franco, L ;
Gómez, F ;
Iglesias, A ;
Pazos, A ;
Pena, J ;
Lobato, R ;
Mosquera, J ;
Pombar, M ;
Sendón, J .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (08) :1703-1716
[8]   A MATRIX IONIZATION-CHAMBER IMAGING DEVICE FOR ONLINE PATIENT SETUP VERIFICATION DURING RADIOTHERAPY [J].
VANHERK, M ;
MEERTENS, H .
RADIOTHERAPY AND ONCOLOGY, 1988, 11 (04) :369-378
[9]   THE USE OF LIQUIDS IN IONIZATION CHAMBERS FOR HIGH-PRECISION RADIOTHERAPY DOSIMETRY [J].
WICKMAN, G ;
NYSTROM, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (09) :1789-1812
[10]   Liquid ionization chambers for absorbed dose measurements in water at low dose rates and intermediate photon energies [J].
Wickman, G ;
Johansson, B ;
Bahar-Gogani, J ;
Holmstrom, T ;
Grindborg, JE .
MEDICAL PHYSICS, 1998, 25 (06) :900-907