Hypercoagulability (thrombin generation) in patients with cirrhosis is detected with ST-Genesia

被引:29
作者
Talon, Laurie [1 ]
Sinegre, Thomas [1 ]
Lecompte, Thomas [2 ]
Pereira, Bruno [3 ]
Massoulie, Sylvie [4 ]
Abergel, Armand [4 ]
Lebreton, Aurelien [1 ]
机构
[1] CHU Clermont Ferrand, Serv Hematol Biol, Clermont Ferrand, France
[2] Univ Geneva, Hop Univ Geneve, Fac Med GpG, Dept Med,Unite Hemostase, Geneva, Switzerland
[3] CHU Clermont Ferrand, Unite Biostat Direct Rech Clin & Innovat, Clermont Ferrand, France
[4] CHU Clermont Ferrand, Serv Hepatogastroenterol, Clermont Ferrand, France
关键词
blood coagulation; blood coagulation test; clinical laboratory techniques; liver cirrhosis; thrombomodulin; PORTAL-VEIN THROMBOSIS; VENOUS THROMBOEMBOLISM; LIVER-CIRRHOSIS; PROTEIN-C; THROMBOMODULIN; THROMBOGRAPHY; NORMALIZATION; HEMOSTASIS; VARIABLES; DISEASE;
D O I
10.1111/jth.14963
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Thrombin generation assays (TGAs) performed with calibrated automated thrombography (CAT) in the presence of thrombomodulin (TM) indicate plasma hypercoagulability in cirrhosis. Objective To evaluate, in the presence of TM, the new ST-Genesia automated device developed for improving TGA vs the previously used CAT method, with plasma samples of patients with cirrhosis. Patients/Methods Platelet-poor plasma samples were prepared from citrated blood samples of 52 healthy controls and 85 patients with cirrhosis (severity evaluated using the Child-Pugh score [CP]). TGAs were performed using CAT with PPP-Reagent and ST-Genesia with the STG-ThromboScreen reagent, in the presence of TM. Endogenous thrombin potential (ETP) was chosen as the main parameter. Results Whatever the method, ETP values were higher in patients than in healthy controls. All patients identified as hypercoagulable with ST-Genesia and STG-ThromboScreen were found hypercoagulable with CAT and PPP-Reagent. Conversely, eight and ten patients in the CP-A and CP-B classes respectively were identified as hypercoagulable only with CAT. The use of ST-Genesia with the STG-ThromboScreen reagent with TM led to a bias, with higher ETP values for healthy controls and lower for patients compared with CAT. Crossover analysis (CAT with the STG-ThromboScreen reagent) evidenced a substantial effect of the STG-ThromboScreen reagent; the analyzer (including calibration and data analysis) plays a lesser role. Conclusion ST-Genesia evidences hypercoagulability in patients with cirrhosis when TG is studied in the presence of TM, but the results are not interchangeable with those obtained with CAT.
引用
收藏
页码:2177 / 2190
页数:14
相关论文
共 39 条
[1]   The incidence of venous thromboembolism and practice of deep venous thrombosis prophylaxis in hospitalized cirrhotic patients [J].
Aldawood A. ;
Arabi Y. ;
Aljumah A. ;
Alsaadi A. ;
Rishu A. ;
Aldorzi H. ;
Alqahtani S. ;
Alsultan M. ;
Felemban A. .
Thrombosis Journal, 9 (1)
[2]   The risk of venous thromboembolism in patients with cirrhosis A systematic review and meta-analysis [J].
Ambrosino, Pasquale ;
Tarantino, Luciano ;
Di Minno, Giovanni ;
Paternoster, Mariano ;
Graziano, Vincenzo ;
Petitto, Maurizio ;
Nasto, Aurelio ;
Di Minno, Matteo Nicola Dario .
THROMBOSIS AND HAEMOSTASIS, 2017, 117 (01) :139-148
[3]   Thrombin generation measurement using the ST Genesia Thrombin Generation System in a cohort of healthy adults: Normal values and variability [J].
Calzavarini, Sara ;
Brodard, Justine ;
Quarroz, Claudia ;
Maire, Livia ;
Nuetzi, Raphael ;
Jankovic, Jovana ;
Rotondo, Laura C. ;
Giabbani, Evelyne ;
Fiedler, Georg Martin ;
Nagler, Michael ;
Angelillo-Scherrer, Anne .
RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS, 2019, 3 (04) :758-768
[4]   Increased thrombin generation in splanchnic vein thrombosis is related to the presence of liver cirrhosis and not to the thrombotic event [J].
Chaireti, Roza ;
Rajani, Rupesh ;
Bergquist, Annika ;
Melin, Tor ;
Friis-Liby, Inga-Lill ;
Kapraali, Marjo ;
Kechagias, Stergios ;
Lindahl, Tomas L. ;
Almer, Sven .
THROMBOSIS RESEARCH, 2014, 134 (02) :455-461
[5]  
Cohen J., 1988, Statistical power analysis for the behavioral sciences, V2nd
[6]   Standardisation of thrombin generation test - which reference plasma for TGT?: An international multicentre study [J].
Dargaud, Y. ;
Luddington, R. ;
Gray, E. ;
Lecompte, T. ;
Siegemund, T. ;
Baglin, T. ;
Hogwood, J. ;
Regnault, V. ;
Siegemund, A. ;
Negrier, C. .
THROMBOSIS RESEARCH, 2010, 125 (04) :353-356
[7]   Effect of standardization and normalization on imprecision of calibrated automated thrombography: an international multicentre study [J].
Dargaud, Yesim ;
Luddington, Rodger ;
Gray, Elaine ;
Negrier, Claude ;
Lecompte, Thomas ;
Petros, Sirak ;
Hogwood, John ;
Bordet, Jean-Claude ;
Hogwood, John ;
Bordet, Jean-Claude ;
Regnault, Veronique ;
Siegemund, Annelie ;
Baglin, Trevor .
BRITISH JOURNAL OF HAEMATOLOGY, 2007, 139 (02) :303-309
[8]   Thrombin generation is extremely sensitive to preheating conditions [J].
de Smedt, E. ;
Hemker, H. C. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 (01) :234-234
[9]   Comparative study of coagulation and thrombin generation in the portal and jugular plasma of patients with cirrhosis [J].
Delahousse, Benedicte ;
Labat-Debelleix, Valerie ;
Decalonne, Loic ;
d'Alteroche, Louis ;
Perarnau, Jean-Marc ;
Gruel, Yves .
THROMBOSIS AND HAEMOSTASIS, 2010, 104 (04) :741-749
[10]   Liver stiffness and thrombin generation in compensated cirrhosis [J].
Dillon, Audrey ;
Egan, Karl ;
Kevane, Barry ;
Galvin, Zita ;
Maguire, Patricia ;
Ni Ainle, Fionnuala ;
Stewart, Stephen .
RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS, 2019, 3 (02) :291-297