Shaking table test on the seismic failure characteristics of a subway station structure on liquefiable ground

被引:171
作者
Chen, Guoxing [1 ,2 ]
Wang, Zhihua [1 ,2 ]
Zuo, Xi [1 ,2 ]
Du, Xiuli [3 ]
Gao, Hongmei [1 ,2 ]
机构
[1] Nanjing Univ Technol, Inst Geotech Engn, Nanjing 210009, Jiangsu, Peoples R China
[2] Beijing Univ Technol, Civil Engn & Earthquake Disaster Prevent Ctr Jian, Beijing 100022, Peoples R China
[3] Beijing Univ Technol, Coll Architecture & Civil Engn, Beijing 100022, Peoples R China
基金
中国国家自然科学基金;
关键词
subway station structure; failure characteristics; liquefiable ground; shaking table test; main shock; aftershock; UNDERGROUND STRUCTURES; EARTHQUAKE;
D O I
10.1002/eqe.2283
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to investigate the seismic failure characteristics of a structure on the liquefiable ground, a series of shaking table tests were conducted based on a plaster model of a three-story and three-span subway station. The dynamic responses of the structure and ground soil under main shock and aftershock ground motions were studied. The sand boils and waterspouts phenomena, ground surface cracks, and earthquake-induced ground surface settlements were observed in the testing. For the structure, the upward movement, local damage and member cracking were obtained. Under the main shock, there appeared longer liquefaction duration for the ground soil while the pore pressure dissipated slowly. The acceleration amplification effect of the liquefied soil was weakened, and the soil showed a remarkable shock absorption and concentration effect with low frequency component of ground motion. However, under the aftershock, the dissipation of pore pressure in the ground soil became obvious. The peak acceleration of the structure reduced with the buried depth. Dynamic soil pressure on the side wall was smaller in the middle and larger at both ends. The interior column of the model structure was the weakest member. The peak strain and damage degree for both sides of the interior column exhibited an S' type distribution along the height. Moreover, the seismic response of both ground soil and subway station structure exhibited a remarkable spatial effect. The seismic damage development process and failure mechanism of the structure illustrated in this study can provide references for the engineers and researcher. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:1489 / 1507
页数:19
相关论文
共 21 条
[1]   The collapse mechanism of a subway station during the Great Hanshin earthquake [J].
An, XH ;
Shawky, AA ;
Maekawa, K .
CEMENT & CONCRETE COMPOSITES, 1997, 19 (03) :241-257
[2]   FOREWORD [J].
Chen, Goong ;
Yao, Pengfei ;
Yong, Jiongmin ;
Zhang, Bingyu ;
Zhang, Xu .
DISCRETE AND CONTINUOUS DYNAMICAL SYSTEMS-SERIES B, 2010, 14 (04) :1-1
[3]   Shaking table model test of subway station structure under far field and near field ground motion [J].
Chen G.-X. ;
Zuo X. ;
Wang Z.-H. ;
Du X.-L. ;
Sun T. .
Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2010, 44 (10) :1955-1961
[4]  
[陈国兴 Chen Guoxing], 2010, [土木工程学报, China Civil Engineering Journal], V43, P120
[5]  
[陈国兴 CHEN Guoxing], 2007, [地震工程与工程振动, Earthquake Engineering and Engineering Vibration], V27, P171
[6]  
[韩晓健 Han Xiaojian], 2010, [防灾减灾工程学报, Journal of Disaster Prevention and Mitigation Engineering], V30, P503
[7]   Seismic design and analysis of underground structures [J].
Hashash, YMA ;
Hook, JJ ;
Schmidt, B ;
Yao, JIC .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2001, 16 (04) :247-293
[8]   Load transfer mechanisms between underground structure and surrounding ground:: Evaluation of the failure of the Daikai Station [J].
Huo, H ;
Bobet, A ;
Fernández, G ;
Ramírez, J .
JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2005, 131 (12) :1522-1533
[9]  
Ito K., 2006, STURCTURAL ENG EARTH, V23, P117
[10]  
Iwatate T., 2000, P 12 WORLD C EARTHQ, P1043