Rapid detection and enumeration of Legionella pneumophila in hot water systems by solid-phase cytometry

被引:42
作者
Aurell, H
Catala, P
Farge, P
Wallet, F
Le Brun, M
Helbig, JH
Jarraud, S
Lebaron, P [1 ]
机构
[1] Univ Paris 06, Inst Natl Sci Univers, CNRS, UMR 7621,Observ Oceanol,Lab Arago, F-66651 Banyuls sur Mer, France
[2] Fac Med Laennec, Bacteriol Lab, INSERM E0230, Ctr Natl Ref Legionella, F-69372 Lyon, France
[3] Elect France, Div Rech & Dev, F-78401 Chatou, France
[4] Tech Univ Dresden, Inst Med Microbiol & Hyg, D-01307 Dresden, Germany
关键词
D O I
10.1128/AEM.70.3.1651-1657.2004
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A new method for the rapid and sensitive detection of Legionella pneumophild in hot water systems has been developed. The method is based on an IF assay combined with detection by solid-phase cytometry. This method allowed the enumeration of L. pneumophila serogroup 1 and L. pneumophila serogroups 2 to 6, 8 to 10, and 12 to 15 in tap water samples within 3 to 4 It. The sensitivity of the method was between 10 and 100 bacteria per liter and was principally limited by the filtration capacity of membranes. The specificity of the antibody was evaluated against 15 non-Legionella strains, and no cross-reactivity was observed. When the method was applied to natural waters, direct counts of L. pneumophila were compared with the number of CFU obtained by the standard culture method. Direct counts were always higher than culturable counts, and the ratio between the two methods ranged from 1.4 to 325. Solid-phase cytometry offers a fast and sensitive alternative to the culture method for L. pneumophila screening in hot water systems.
引用
收藏
页码:1651 / 1657
页数:7
相关论文
共 29 条
[1]  
Abu Kwaik Y, 1998, APPL ENVIRON MICROB, V64, P3127
[2]   Rapid and sensitive enumeration of viable diluted cells of members of the family Enterobacteriaceae in freshwater and drinking water [J].
Baudart, J ;
Coallier, J ;
Laurent, P ;
Prévost, M .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2002, 68 (10) :5057-5063
[3]   DETECTION OF VIABLE LEGIONELLA-PNEUMOPHILA IN WATER BY POLYMERASE CHAIN-REACTION AND GENE PROBE METHODS [J].
BEJ, AK ;
MAHBUBANI, MH ;
ATLAS, RM .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1991, 57 (02) :597-600
[4]   Evaluation of detection of Legionella spp. in water samples by fluorescence in situ hybridization, PCR amplification and bacterial culture [J].
Buchbinder, S ;
Trebesius, K ;
Heesemann, J .
INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2002, 292 (3-4) :241-245
[5]   Effectiveness of CSE to counterstain particles and dead bacterial cells with permeabilised membranes: application to viability assessment in waters [J].
Catala, P ;
Parthuisot, N ;
Bernard, L ;
Baudart, J ;
Lemarchand, K ;
Lebaron, P .
FEMS MICROBIOLOGY LETTERS, 1999, 178 (02) :219-226
[6]   Detection of Legionella pneumophila in wastewater by nested polymerase chain reaction [J].
Catalan, V ;
Garcia, F ;
Moreno, C ;
Vila, MJ ;
Apraiz, D .
RESEARCH IN MICROBIOLOGY, 1997, 148 (01) :71-78
[7]   A detection method for Legionella spp in (cooling) water:: fluorescent in situ hybridisation (FISH) on whole bacteria [J].
Declerck, P ;
Verelst, L ;
Duvivier, L ;
Van Damme, A ;
Ollevier, F .
WATER SCIENCE AND TECHNOLOGY, 2003, 47 (03) :143-146
[8]  
Fallon R J, 1980, J Hosp Infect, V1, P299, DOI 10.1016/0195-6701(80)90005-5
[9]   Legionella and Legionnaires' disease:: 25 years of investigation [J].
Fields, BS ;
Benson, RF ;
Besser, RE .
CLINICAL MICROBIOLOGY REVIEWS, 2002, 15 (03) :506-+
[10]   Antigenic lipopolysaccharide components of Legionella pneumophila recognized by monoclonal antibodies: Possibilities and limitations for division of the species into serogroups [J].
Helbig, JH ;
Kurtz, JB ;
Pastoris, MC ;
Pelaz, C ;
Luck, PC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (11) :2841-2845