Extra-pleuric coaxial system for CT-guided percutaneous fine-needle aspiration biopsy (FNAB) of small (≤20 mm) lung nodules: a novel technique using multiplanar reconstruction (MPR) images

被引:10
作者
Capasso, Raffaella [1 ]
Nizzoli, Rita [2 ]
Tiseo, Marcello [2 ]
Pedrazzi, Giuseppe [3 ]
Brunese, Luca [1 ]
Rotondo, Antonio [4 ]
De Filippo, Massimo [5 ]
机构
[1] Univ Molise, Dept Med & Hlth Sci V Tiberio, Via Francesco De Sanctis,1, I-86100 Campobasso, Italy
[2] Univ Hosp Parma, Med Oncol Unit, Via Gramsci,14, I-43100 Parma, Italy
[3] Univ Parma, Dept Neurosci, Via Gramsci,14, I-43100 Parma, Italy
[4] Univ Naples 2, Dept Internal & Expt Med, Piazza Miraglia,2, I-80138 Naples, Italy
[5] Univ Parma, Parma Hosp, Dept Radiol, Via Gramsci,14, I-43100 Parma, Italy
关键词
Coaxial technique; Lung biopsy; CT guidance; Small nodule; Pneumothorax; MPR; PULMONARY NODULES; DIAGNOSTIC-ACCURACY; PNEUMOTHORAX RATE; RISK-FACTORS; LESIONS; EXPERIENCE; COMPLICATIONS; SAFETY;
D O I
10.1007/s12032-016-0871-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of the study is to present the diagnostic feasibility, usefulness, and safety of a novel technique for coaxial CT-guided fine-needle aspiration biopsy of small (<= 20 mm in diameter) lung nodules. A 18-gauge (G) (1.2 x 40 mm) needle is inserted through the skin in the depth of the thoracic wall tissues remaining outside the pleura. Its positioning is planned and adjusted using multiplanar reconstruction (MPR) images along the 18-G guide needle axis tracing a reference outline extended from the needle tip to the target nodule. When the insertion of the 18-G extra-pleuric needle (EPN) proves to be precise, a 22-G Chiba needle is then passed through the outer 18-G EPN until it reaches the thoracic lesion for the sampling procedure. Patient population included 153 males and 94 females, with a mean age of 61.3 +/- 21.6 years. Mean nodule diameter was 14.1 +/- 2.2 mm. The lesion depth from pleural plane ranged from 0 mm to 127 mm. An average of 1.29 aspirates were performed per lesion. The most common complication was pneumothorax in 27 cases; there were no cases of PNX requiring chest tube insertion. Intrapulmonary bleeding along the needle track was observed in 32 patients. Exploiting the advantage of MPR images, our novel technique of extra-pleuric coaxial system with a 18-G EPN allows the operator to multiple samplings of small (<= 20 mm) target lesions in various locations with a thinner (22-G Chiba) needle, thus reducing the degree of pleural, parenchymal, or adjacent organs damage.
引用
收藏
页数:10
相关论文
共 22 条
[1]  
Carrafiello G, 2012, RADIOL MED, V117, P201, DOI 10.1007/s11547-011-0741-2
[2]   Advantages of multidetector-row CT with multiplanar reformation in guiding percutaneous lung biopsies [J].
De Filippo, M. ;
Onniboni, M. ;
Rusca, M. ;
Carbognani, P. ;
Ferrari, L. ;
Guazzi, A. ;
Casalini, A. ;
Verardo, E. ;
Cataldi, V. ;
Tiseo, M. ;
Sverzellati, N. ;
Chiari, G. ;
Rabaiotti, E. ;
Corsi, A. ;
Cacciani, G. ;
Sommario, M. ;
Ardizzoni, A. ;
Zompatori, M. .
RADIOLOGIA MEDICA, 2008, 113 (07) :945-953
[3]  
De Filippo Massimo, 2016, Acta Biomed, V87 Suppl 3, P57
[4]   Curved Needles in CT-Guided Fine Needle Biopsies of Abdominal and Retroperitoneal Small Lesions [J].
De Filippo, Massimo ;
Saba, Luca ;
Rossi, Enrica ;
Nizzoli, Rita ;
Tiseo, Marcello ;
Pedrazzi, Giuseppe ;
Brunese, Luca ;
Rotondo, Antonio ;
Rossi, Cristina .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (06) :1611-1616
[5]   CT-guided biopsy of pulmonary nodules: is pulmonary hemorrhage a complication or an advantage? [J].
De Filippo, Massimo ;
Saba, Luca ;
Silva, Mario ;
Zagaria, Raffaella ;
Concari, Giorgio ;
Nizzoli, Rita ;
Bozzetti, Cecilia ;
Tiseo, Marcello ;
Ardizzoni, Andrea ;
Lipia, Stefano ;
Paladini, Ilaria ;
Macarini, Luca ;
Carrafiello, Giampaolo ;
Brunese, Luca ;
Rotondo, Antonio ;
Rossi, Cristina .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2014, 20 (05) :421-425
[6]   Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules [J].
De Filippo, Massimo ;
Saba, Luca ;
Concari, Giorgio ;
Nizzoli, Rita ;
Ferrari, Lilia ;
Tiseo, Marcello ;
Ardizzoni, Andrea ;
Sverzellati, Nicola ;
Paladini, Ilaria ;
Ganazzoli, Chiara ;
Sconfienza, Luca Maria ;
Carrafiello, Giampaolo ;
Brunese, Luca ;
Genovese, Eugenio Annibale ;
Ampollini, Luca ;
Carbognani, Paolo ;
Rusca, Michele ;
Zompatori, Maurizio ;
Rossi, Cristina .
RADIOLOGIA MEDICA, 2013, 118 (07) :1071-1081
[7]   CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: Needle size and pneumothorax rate [J].
Geraghty, PR ;
Kee, ST ;
McFarlane, G ;
Razavi, MK ;
Sze, DY ;
Dake, MD .
RADIOLOGY, 2003, 229 (02) :475-481
[8]   CT-guided biopsy of lung lesions: defining the best needle option for a specific diagnosis [J].
Guimaraes, Marcos Duarte ;
Marchiori, Edson ;
Hochhegger, Bruno ;
Chojniak, Rubens ;
Gross, Jefferson Luiz .
CLINICS, 2014, 69 (05) :335-340
[9]   Usefulness and safety of biliary percutaneous transluminal forceps biopsy (PTFB): our experience [J].
Ierardi, Anna Maria ;
Mangini, Monica ;
Fontana, Federico ;
Floridi, Chiara ;
De Marchi, Giuseppe ;
Petrillo, Mario ;
Capasso, Raffaella ;
Chini, Claudio ;
Cocozza, Eugenio ;
Cuffari, Salvatore ;
Segato, Sergio ;
Rotondo, Antonio ;
Carrafiello, Gianpaolo .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2014, 23 (02) :96-101
[10]   Factors influencing pneumothorax rate at lung biopsy: Are dwell time and angle of pleural puncture contributing factors? [J].
Ko, JP ;
Shepard, JAO ;
Drucker, EA ;
Aquino, SL ;
Sharma, A ;
Sabloff, B ;
Halpern, E ;
McLoud, TC .
RADIOLOGY, 2001, 218 (02) :491-496