Estimation of the number of feeding arteries of spinal arteriovenous malformations by using three-dimensional digital subtraction angiography

被引:1
|
作者
Takamiya, Soichiro [1 ,2 ]
Osanai, Toshiya [1 ,2 ]
Seki, Toshitaka [1 ,2 ]
Fujima, Noriyuki [3 ]
Hida, Kazutoshi [4 ]
Asano, Takeshi [5 ]
Yamazaki, Kazuyoshi [1 ,2 ]
Hamauchi, Shuji [1 ,2 ]
Sasamori, Toru [4 ]
Ono, Kota [6 ]
Terasaka, Shunsuke [1 ,2 ]
Houkin, Kiyohiro [1 ,2 ]
机构
[1] Hokkaido Univ, Fac Med, Dept Neurosurg, Sapporo, Hokkaido, Japan
[2] Hokkaido Univ, Grad Sch Med, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ Hosp, Dept Diagnost & Intervent Radiol, Sapporo, Hokkaido, Japan
[4] Sapporo Azabu Neurosurg Hosp, Dept Neurosurg, Sapporo, Hokkaido, Japan
[5] Chiba Med Ctr, Dept Neuroendovasc, Chiba, Japan
[6] Hokkaido Univ Hosp, Clin Res & Med Innovat Ctr, Sapporo, Hokkaido, Japan
关键词
Spinal arteriovenous malformations; 3D-DSA; F; D ratio; Estimation; Perimedullary AVF; Intramedullary AVM;
D O I
10.1007/s00586-018-5852-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposeSpinal angiography is the gold standard for evaluation or diagnosis of spinal arteriovenous malformations (AVMs). However, some feeding arteries might be overlooked when multiple feeders exist. This study aimed to retrospectively review cases of spinal intra-dural AVMs, which were identified by three-dimensional digital subtraction angiography (3D-DSA), and attempted to estimate the number of feeding arteries.MethodsWe retrospectively reviewed patients with spinal intra-dural AVMs who underwent 3D-DSA at Hokkaido University Hospital from January 2005 to December 2016. We selected 9 patients in whom we could obtain data of multi-planar reconstruction of 3D-DSA. We measured the computed tomography (CT) values of feeding arteries and draining veins. The CT values represented the averages of maximum CT values of 5 continuous axial slices. The ratio of the CT value of feeders to that of drainers (F/D ratio) was calculated. The correlation between the F/D ratio and the number of feeders was examined with Pearson's correlation coefficient.ResultsThe average number of feeders was 2.3 (1-4), and the number of feeders was significantly positively correlated with the F/D ratio (r=0.855, P=.003).ConclusionsWe conclude that the number of feeding arteries of spinal intra-dural AVMs can be estimated by using the F/D ratio obtained from 3D-DSA [GRAPHICS]
引用
收藏
页码:842 / 848
页数:7
相关论文
共 50 条
  • [1] Estimation of the number of feeding arteries of spinal arteriovenous malformations by using three-dimensional digital subtraction angiography
    Soichiro Takamiya
    Toshiya Osanai
    Toshitaka Seki
    Noriyuki Fujima
    Kazutoshi Hida
    Takeshi Asano
    Kazuyoshi Yamazaki
    Shuji Hamauchi
    Toru Sasamori
    Kota Ono
    Shunsuke Terasaka
    Kiyohiro Houkin
    European Spine Journal, 2019, 28 : 842 - 848
  • [2] INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY OF SPINAL ARTERIOVENOUS-MALFORMATIONS
    DOPPMAN, JL
    KRUDY, AG
    MILLER, DL
    OLDFIELD, E
    DICHIRO, G
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1983, 4 (05) : 1081 - 1085
  • [3] Fusion Technique Using Three-Dimensional Digital Subtraction Angiography in the Evaluation of Complex Cerebral and Spinal Vascular Malformations
    Fukuda, Kenji
    Higashi, Toshio
    Okawa, Masakazu
    Iwaasa, Mitsutoshi
    Abe, Hiroshi
    Inoue, Tooru
    WORLD NEUROSURGERY, 2016, 85 : 353 - 358
  • [4] Usefulness of three-dimensional digital subtraction angiography in endovascular treatment of a spinal dural arteriovenous fistula
    Matsubara, Noriaki
    Miyachi, Shigeru
    Izumi, Takashi
    Ohshima, Tomotaka
    Tsurumi, Auhito
    Hososhimn, Osamu
    Kinkori, Takeshi
    Yoshida, Jun
    JOURNAL OF NEUROSURGERY-SPINE, 2008, 8 (05) : 462 - 467
  • [5] A Prospective Study Comparing the Three-Dimensional Rotational Angiography and Two-Dimensional Digital Subtraction Angiography in Evaluation of Brain Arteriovenous Malformations
    Pan, Somnath
    Kannath, Santhosh K.
    Singh, Gurpreet
    Rajan, Jayadevan E.
    NEUROLOGY INDIA, 2022, 70 (05) : 1905 - +
  • [6] Three-dimensional reconstructed images of renal arteries using rotational digital subtraction angiography
    Endoh, H
    Shimizu, T
    Kodama, Y
    Miyasaka, K
    RADIOLOGY, 2001, 221 : 185 - 185
  • [7] Three-dimensional dynamic MR digital subtraction angiography using sensitivity encoding for the evaluation of intracranial arteriovenous malformations: A preliminary study
    Gauvrit, JY
    Leclerc, X
    Oppenheim, C
    Munier, T
    Trystram, D
    Rachdi, H
    Nataf, F
    Pruvo, JP
    Meder, JF
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (06) : 1525 - 1531
  • [8] Evaluation of Cerebral Arteriovenous Malformations Using Image Fusion Combining Three-Dimensional Digital Subtraction Angiography with Magnetic Resonance Imaging
    Suzuki, Hidenori
    Maki, Hiroaki
    Taki, Waro
    TURKISH NEUROSURGERY, 2012, 22 (03) : 341 - 345
  • [9] Four-dimensional digital subtraction angiography to assess cerebral arteriovenous malformations
    Xiang, Weichu
    Yan, Linhai
    Zhao, Yueyuan
    Yang, Ming
    Bai, Sanli
    Ma, Lianting
    Pan, Li
    JOURNAL OF NEUROIMAGING, 2023, 33 (01) : 67 - 72
  • [10] Spatiotemporal Disentanglement of Arteriovenous Malformations in Digital Subtraction Angiography
    Baur, Kathleen
    Xiong, Xin
    Torio, Erickson
    Du, Rose
    Juvekar, Parikshit
    Dorent, Reuben
    Golby, Alexandra
    Frisken, Sarah
    Haouchine, Nazim
    MEDICAL IMAGING 2024: IMAGE PROCESSING, 2024, 12926