Abnormal Pulmonary Artery Stiffness in Pulmonary Arterial Hypertension: In Vivo Study with Intravascular Ultrasound

被引:37
作者
Lau, Edmund M. T. [1 ,2 ,3 ]
Iyer, Nithin [3 ]
Ilsar, Rahn [1 ]
Bailey, Brian P. [1 ]
Adams, Mark R. [1 ,3 ]
Celermajer, David S. [1 ,3 ]
机构
[1] Royal Prince Alfred Hosp, Dept Cardiol, Camperdown, NSW 2050, Australia
[2] Royal Prince Alfred Hosp, Dept Resp & Sleep Med, Camperdown, NSW 2050, Australia
[3] Univ Sydney, Sydney Med Sch, Camperdown, NSW, Australia
基金
英国医学研究理事会;
关键词
MAGNETIC-RESONANCE; CLINICAL-APPLICATIONS; VASCULAR-RESISTANCE; DISTENSIBILITY; PRESSURE; FLOW; CAPACITANCE; MORTALITY; IMPEDANCE; DISEASE;
D O I
10.1371/journal.pone.0033331
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: There is increasing recognition that pulmonary artery stiffness is an important determinant of right ventricular (RV) afterload in pulmonary arterial hypertension (PAH). We used intravascular ultrasound (IVUS) to evaluate the mechanical properties of the elastic pulmonary arteries (PA) in subjects with PAH, and assessed the effects of PAH-specific therapy on indices of arterial stiffness. Method: Using IVUS and simultaneous right heart catheterisation, 20 pulmonary segments in 8 PAH subjects and 12 pulmonary segments in 8 controls were studied to determine their compliance, distensibility, elastic modulus and stiffness index beta. PAH subjects underwent repeat IVUS examinations after 6-months of bosentan therapy. Results: At baseline, PAH subjects demonstrated greater stiffness in all measured indices compared to controls: compliance (1.50 +/- 0.11 x 10(-2) mm(2)/mmHg vs 4.49 +/- 0.43 x 10(-2) mm(2)/mmHg, p<0.0001), distensibility (0.32 +/- 0.03%/mmHg vs 1.18 +/- 0.13%/mmHg, p<0.0001), elastic modulus (720 +/- 64 mmHg vs 198 +/- 19 mmHg, p<0.0001), and stiffness index b (15.0 +/- 1.4 vs 11.0 +/- 0.7, p = 0.046). Strong inverse exponential associations existed between mean pulmonary artery pressure and compliance (r(2) = 0.82, p<0.0001), and also between mean PAP and distensibility (r(2) = 0.79, p = 0.002). Bosentan therapy, for 6-months, was not associated with any significant changes in all indices of PA stiffness. Conclusion: Increased stiffness occurs in the proximal elastic PA in patients with PAH and contributes to the pathogenesis RV failure. Bosentan therapy may not be effective at improving PA stiffness.
引用
收藏
页数:6
相关论文
共 32 条
[1]   PULMONARY-ARTERY DISTENSIBILITY AND BLOOD-FLOW PATTERNS - A MAGNETIC-RESONANCE STUDY OF NORMAL SUBJECTS AND OF PATIENTS WITH PULMONARY ARTERIAL-HYPERTENSION [J].
BOGREN, HG ;
KLIPSTEIN, RH ;
MOHIADDIN, RH ;
FIRMIN, DN ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
AMERICAN HEART JOURNAL, 1989, 118 (05) :990-999
[2]  
Borges AC, 1997, EUR HEART J, V18, P1988
[3]   Intravascular ultrasound assessment of pulmonary vascular disease in patients with pulmonary hypertension [J].
Bressollette, E ;
Dupuis, J ;
Bonan, R ;
Doucet, S ;
Cernacek, P ;
Tardif, JC .
CHEST, 2001, 120 (03) :809-815
[4]   Guidelines for the diagnosis and treatment of pulmonary hypertension [J].
Galie, Nazzareno ;
Hoeper, Marius M. ;
Humbert, Marc ;
Torbicki, Adam ;
Vachiery, Jean-Luc ;
Albert Barbera, Joan ;
Beghetti, Maurice ;
Corris, Paul ;
Gaine, Sean ;
Gibbs, J. Simon ;
Angel Gomez-Sanchez, Miguel ;
Jondeau, Guillaume ;
Klepetko, Walter ;
Opitz, Christian ;
Peacock, Andrew ;
Rubin, Lewis ;
Zellweger, Michael ;
Simonneau, Gerald .
EUROPEAN HEART JOURNAL, 2009, 30 (20) :2493-2537
[5]   Noninvasively assessed pulmonary artery stiffness predicts mortality in pulmonary arterial hypertension [J].
Gan, C. Tji-Joong ;
Lankhaar, Jan-Willem ;
Westerhof, Nico ;
Marcus, J. Tim ;
Becker, Annemarie ;
Twisk, Jos W. R. ;
Boonstra, Anco ;
Postmus, Pieter E. ;
Vonk-Noordegraaf, Anton .
CHEST, 2007, 132 (06) :1906-1912
[6]  
Grignola JC, 2011, INT J CARDIOL
[7]   STIFFNESS OF SYSTEMIC ARTERIES IN PATIENTS WITH MYOCARDIAL-INFARCTION - A NONINVASIVE METHOD TO PREDICT SEVERITY OF CORONARY ATHEROSCLEROSIS [J].
HIRAI, T ;
SASAYAMA, S ;
KAWASAKI, T ;
YAGI, S .
CIRCULATION, 1989, 80 (01) :78-86
[8]   Feasibility of routine pulmonary arterial impedance measurements in pulmonary hypertension [J].
Huez, S ;
Brimioulle, S ;
Naeije, R ;
Vachiéry, JL .
CHEST, 2004, 125 (06) :2121-2128
[9]   Drug therapy: Treatment of pulmonary arterial hypertension [J].
Humbert, M ;
Sitbon, O ;
Simonneau, G .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (14) :1425-1436
[10]   Pulmonary vascular input impedance is a combined measure of pulmonary vascular resistance and stiffness and predicts clinical outcomes better than pulmonary vascular resistance alone in pediatric patients with pulmonary hypertension [J].
Hunter, Kendall S. ;
Lee, Po-Feng ;
Lanning, Craig J. ;
Ivy, D. Dunbar ;
Kirby, K. Scott ;
Claussen, Lori R. ;
Chan, K. Chen ;
Shandas, Robin .
AMERICAN HEART JOURNAL, 2008, 155 (01) :166-174