Quantitative Computed Tomography Imaging Biomarkers in the Diagnosis and Management of Lung Cancer

被引:45
作者
Kim, Hyungjin [1 ,2 ,3 ]
Park, Chang Min [1 ,2 ,4 ]
Goo, Jin Mo [1 ,2 ,4 ]
Wildberger, Joachim E. [5 ]
Kauczor, Hans-Ulrich [6 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul 110744, South Korea
[3] Air Force Educ & Training Command, Aerosp Med Grp, Jinju, South Korea
[4] Seoul Natl Univ, Canc Res Inst, Seoul, South Korea
[5] Maastricht Univ, Med Ctr, Dept Radiol, Maastricht, Netherlands
[6] Heidelberg Univ, Dept Diagnost & Intervent Radiol, Heidelberg, Germany
关键词
lung cancer; imaging biomarker; volumetry; perfusion imaging; texture analysis; GROUND-GLASS OPACITY; THIN-SECTION CT; ITERATIVE RECONSTRUCTION TECHNIQUE; SOLITARY PULMONARY NODULES; CONTRAST-ENHANCED CT; TEXTURE ANALYSIS; TUMOR VOLUME; PROGNOSTIC VALUE; PERFUSION CT; IASLC/ATS/ERS CLASSIFICATION;
D O I
10.1097/RLI.0000000000000152
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Tumor diameter has traditionally been used as a standard metric in terms of diagnosis and prognosis prediction of lung cancer. However, recent advances in imaging techniques and data analyses have enabled novel quantitative imaging biomarkers that can characterize disease status more comprehensively and/or predict tumor behavior more precisely. The most widely used imaging modality for lung tumor assessment is computed tomography. Therefore, we focused on computed tomography imaging biomarkers such as tumor volume and mass, ground-glass opacities, perfusion parameters, as well as texture features in this review. Herein, we first appraised the conventional 1- or 2-dimensional measurement with brief discussion on their limits and then introduced the potential imaging biomarkers with emphasis on the current understanding of their clinical usefulness with respect to the malignancy differentiation, treatment response monitoring, and patient outcome prediction.
引用
收藏
页码:571 / 583
页数:13
相关论文
共 110 条
[71]   The ground glass opacity component can be eliminated from the T-factor assessment of lung adenocarcinoma [J].
Murakawa, Tomohiro ;
Konoeda, Chihiro ;
Ito, Takuya ;
Inoue, Yuta ;
Sano, Atsushi ;
Nagayama, Kazuhiro ;
Nakajima, Jun .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 43 (05) :925-932
[72]   Recommendations for the Management of Subsolid Pulmonary Nodules Detected at CT: A Statement from the Fleischner Society [J].
Naidich, David P. ;
Bankier, Alexander A. ;
MacMahon, Heber ;
Schaefer-Prokop, Cornelia M. ;
Pistolesi, Massimo ;
Goo, Jin Mo ;
Macchiarini, Paolo ;
Crapo, James D. ;
Herold, Christian J. ;
Austin, John H. ;
Travis, William D. .
RADIOLOGY, 2013, 266 (01) :304-317
[73]   Angiogenesis in Non-small Cell Lung Cancer Imaging With Perfusion Computed Tomography [J].
Ng, Quan Sing ;
Goh, Vicky .
JOURNAL OF THORACIC IMAGING, 2010, 25 (02) :142-150
[74]   Tumor Volume Decrease at 8 Weeks Is Associated with Longer Survival in EGFR-Mutant Advanced Non-Small-Cell Lung Cancer Patients Treated with EGFR TKI [J].
Nishino, Mizuki ;
Dahlberg, Suzanne E. ;
Cardarella, Stephanie ;
Jackman, David M. ;
Rabin, Michael S. ;
Hatabu, Hiroto ;
Jaenne, Pasi A. ;
Johnson, Bruce E. .
JOURNAL OF THORACIC ONCOLOGY, 2013, 8 (08) :1059-1068
[75]   Quantitative imaging biomarkers in the clinical development of targeted therapeutics: current and future perspectives [J].
O'Connor, James P. B. ;
Jackson, Alan ;
Asselin, Marie-Claude ;
Buckley, David L. ;
Parker, Geoff J. M. ;
Jayson, Gordon C. .
LANCET ONCOLOGY, 2008, 9 (08) :766-776
[76]   Dynamic Contrast-Enhanced CT and MRI for Pulmonary Nodule Assessment [J].
Ohno, Yoshiharu ;
Nishio, Mizuho ;
Koyama, Hisanobu ;
Miura, Sachiko ;
Yoshikawa, Takeshi ;
Matsumoto, Sumiaki ;
Sugimura, Kazuro .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (03) :515-529
[77]   Comparison of Quantitatively Analyzed Dynamic Area-Detector CT Using Various Mathematic Methods With FDG PET/CT in Management of Solitary Pulmonary Nodules [J].
Ohno, Yoshiharu ;
Nishio, Mizuho ;
Koyama, Hisanobu ;
Fujisawa, Yasuko ;
Yoshikawa, Takeshi ;
Matsumoto, Sumiaki ;
Sugimura, Kazuro .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (06) :W593-W602
[78]   Differentiation of Malignant and Benign Pulmonary Nodules with Quantitative First-Pass 320-Detector Row Perfusion CT versus FDG PET/CT [J].
Ohno, Yoshiharu ;
Koyama, Hisanobu ;
Matsumoto, Keiko ;
Onishi, Yumiko ;
Takenaka, Daisuke ;
Fujisawa, Yasuko ;
Yoshikawa, Takeshi ;
Konishi, Minoru ;
Maniwa, Yoshimasa ;
Nishimura, Yoshihiro ;
Ito, Tomoo ;
Sugimura, Kazuro .
RADIOLOGY, 2011, 258 (02) :599-609
[79]   Variability of Lung Tumor Measurements on Repeat Computed Tomography Scans Taken Within 15 Minutes [J].
Oxnard, Geoffrey R. ;
Zhao, Binsheng ;
Sima, Camelia S. ;
Ginsberg, Michelle S. ;
James, Leonard P. ;
Lefkowitz, Robert A. ;
Guo, Pingzhen ;
Kris, Mark G. ;
Schwartz, Lawrence H. ;
Riely, Gregory J. .
JOURNAL OF CLINICAL ONCOLOGY, 2011, 29 (23) :3114-3119
[80]   Commentary - The RECIST criteria: implications for diagnostic radiologists [J].
Padhani, AR ;
Ollivier, L .
BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (887) :983-986