KINEMATIC VARIABLES AND BLOOD ACID-BASE STATUS IN THE ANALYSIS OF COLLEGIATE SWIMMERS' ANAEROBIC CAPACITY

被引:8
作者
Bielec, G. [1 ]
Makar, P. [1 ]
Laskowski, R. [2 ]
Olek, R. A. [3 ]
机构
[1] Gdansk Univ Phys Educ & Sport, Dept Swimming, PL-80336 Gdansk, Poland
[2] Gdansk Univ Phys Educ & Sport, Dept Physiol, PL-80336 Gdansk, Poland
[3] Gdansk Univ Phys Educ & Sport, Dept Biochem, PL-80336 Gdansk, Poland
关键词
stroke rate; stroke length; velocity; base excess; hydrogen ion; SKELETAL-MUSCLE; STROKING CHARACTERISTICS; INTERMITTENT EXERCISE; PARAMETERS; RECOVERY; CONTRACTION; PERFORMANCE; FATIGUE; FIBERS; K+;
D O I
10.5604/20831862.1059303
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Short duration repeated maximal efforts are often used in swimming training to improve lactate tolerance, which gives swimmers the ability to maintain a high work rate for a longer period of time. The aim of the study was to examine the kinematics of swimming and its relation to the changes in blood acid-base status and potassium level. Seven collegiate swimmers, with at least 6 years of training experience, volunteered to participate in the study. The test consisted of 8 x 25 m front crawl performed with maximum effort. The rest period between repetitions was set to five seconds. Blood samples were taken from the fingertip at rest, after warm-up and in the 3rd minute after completion of the test. The swimming was recorded with a video recorder, for later analysis of time, velocity and technique (stroke index). Based on the swimming velocity results, the obtained curve can be divided into rapid decrease of velocity and relatively stable velocities. The breaking point of repetition in swimming velocity was assumed as the swimming velocity threshold and it was highly correlated with the decrease of the blood acid-base status (pH r=0.82, BE r=0.87, HCO3- r=0.76; p<0.05 in all cases). There was no correlation between stroke index or fatigue index and blood acid-base status. Analysis of the swimming speed in the 8 x 25 m test seems to be helpful in evaluation of lactate tolerance (anaerobic capacity) in collegiate swimmers.
引用
收藏
页码:213 / 217
页数:5
相关论文
共 32 条
[1]   Stroking Characteristics during Time to Exhaustion Tests [J].
Alberty, Morgan ;
Sidney, Michel ;
Pelayo, Patrick ;
Toussaint, Huub M. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2009, 41 (03) :637-644
[2]   Exercise and Fatigue [J].
Ament, Wim ;
Verkerke, Gijsbertus J. .
SPORTS MEDICINE, 2009, 39 (05) :389-422
[3]   Physiological response of 5/1 intermittent aerobic exercise and its relationship to 5km endurance performance [J].
Babineau, C ;
Leger, L .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1997, 18 (01) :13-19
[4]   MAXIMAL-INTENSITY INTERMITTENT EXERCISE - EFFECT OF RECOVERY DURATION [J].
BALSOM, PD ;
SEGER, JY ;
SJODIN, B ;
EKBLOM, B .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1992, 13 (07) :528-533
[5]   Relationships between stroke parameters and critical swimming speed in a sprint interval training set [J].
Barden, John M. ;
Kell, Robert T. .
JOURNAL OF SPORTS SCIENCES, 2009, 27 (03) :227-235
[6]   RELAXATION AND FORCE DURING FATIGUE AND RECOVERY OF THE HUMAN QUADRICEPS MUSCLE - RELATIONS TO METABOLITE CHANGES [J].
BERGSTROM, M ;
HULTMAN, E .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1991, 418 (1-2) :153-160
[7]   VARIABILITY IN SWIMMERS' INDIVIDUAL KINEMATICS PARAMETERS VERSUS TRAINING LOADS [J].
Bielec, G. ;
Makar, P. .
BIOLOGY OF SPORT, 2010, 27 (02) :143-147
[8]   RELATION BETWEEN EXTRACELLULAR [K+], MEMBRANE-POTENTIAL AND CONTRACTION IN RAT SOLEUS MUSCLE - MODULATION BY THE NA+-K+ PUMP [J].
CAIRNS, SP ;
FLATMAN, JA ;
CLAUSEN, T .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1995, 430 (06) :909-915
[9]   Stroking characteristic variations in the 100-m freestyle for male swimmers of differing skill [J].
Chollet, D ;
Pelayo, P ;
Delaplace, C ;
Tourny, C ;
Sidney, M .
PERCEPTUAL AND MOTOR SKILLS, 1997, 85 (01) :167-177
[10]   HUMAN MUSCLE METABOLISM DURING INTERMITTENT MAXIMAL EXERCISE [J].
GAITANOS, GC ;
WILLIAMS, C ;
BOOBIS, LH ;
BROOKS, S .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (02) :712-719