Non-Invasive Assessment of Blood Glucose Changes with Near Infrared Sensor

被引:0
|
作者
Mamilov, Serhii [1 ]
Velyhotskyi, Dmytro [1 ]
Yesman, Serhii [1 ]
Mysiura, Anatolii [1 ]
Bekh, Ihor [2 ]
Gisbrecht, Alexander [3 ]
机构
[1] NAS Ukraine, Dept Biotech Syst, Inst Appl Problems Phys & Biophys, Kiev, Ukraine
[2] Taras Shevchenko Natl Univ Kyiv, Fac Radiophys Elect & Comp Syst, Kiev, Ukraine
[3] Bulgarian Acad Sci, Inst Elect, Dept Lab Biophoton, Sofia, Bulgaria
来源
2020 IEEE 40TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO) | 2020年
关键词
glucose; blood; diabetes; optical irradiation; carbohydrate tolerance test; RAMAN-SPECTROSCOPY;
D O I
10.1109/elnano50318.2020.9088873
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The results of the investigation of changes in optical signals of earlobe sensor at 660 and 940 nm and three-wavelengths finger sensor at 660, 850 and 940 nm during performance of 2-hour carbohydrate tolerance test are reported. Carbohydrate tolerance test (CTT) is known as the effective method of in vivo experiments to achieve a fairly wide range of glucose concentrations over a limited period of time. Measurements were carried out for 16 days in 4 non-diabetic volunteers. The results of the present study indicate that a definite optical response to the increase in blood glucose levels during the CTT, expressed after 40 min after carbohydrates uptake is observed at a wavelengths of 850 and 940 nm. The calibration coefficients were determined with the invasive glucometer and the glucose measurement errors on the Clark grid were analyzed. For the development of an optical sensor suitable for non-invasive measurement of blood glucose, further research with the use of other wavelengths in the near infrared range and technical implementation of the control of external parameters (temperature, pressure, humidity, etc.) are required.
引用
收藏
页码:536 / 540
页数:5
相关论文
共 50 条
  • [1] Near-infrared LED based Non-invasive Blood Glucose Sensor
    Yadav, Jyoti
    Rani, Asha
    Singh, Vijander
    Murari, Bhaskar Mohan
    2014 INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND INTEGRATED NETWORKS (SPIN), 2014, : 591 - 594
  • [2] Non-invasive Assessment of Blood Glucose by Photo Plethysmography
    Jindal, G. D.
    Ananthakrishnan, T. S.
    Jain, Rajesh Kumar
    Sinha, Vineet
    Kini, A. R.
    Deshpande, Alakak
    IETE JOURNAL OF RESEARCH, 2008, 54 (03) : 217 - 222
  • [3] Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
    Yadav, Jyoti
    Rani, Asha
    Singh, Vijander
    Murari, Bhaskar Mohan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 18 : 214 - 227
  • [4] Metamaterial Sensor for Microwave Non-invasive Blood Glucose Monitoring
    Vrba, Jan
    Vrba, David
    Diaz, Luis
    Fiser, Ondrej
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 789 - 792
  • [5] Analysis and Design of a Microwave Coplanar Sensor for Non-Invasive Blood Glucose Measurements
    Cebedio, Maria Celeste
    Rabioglio, Lucas Andres
    Gelosi, Ivan Exequiel
    Ribas, Ramiro Avalos
    Uriz, Alejandro Jose
    Moreira, Jorge Castineira
    IEEE SENSORS JOURNAL, 2020, 20 (18) : 10572 - 10581
  • [6] Evaluation of a near-infrared light ultrasound system as a non-invasive blood glucose monitoring device
    Meyhoefer, Svenja
    Wilms, Britta
    Ihling, Flavia
    Windjaeger, Anne
    Kalscheuer, Hannes
    Augustinov, Andrej
    Herrmann, Vera
    Lehnert, Hendrik
    Schmid, Sebastian M.
    DIABETES OBESITY & METABOLISM, 2020, 22 (04) : 694 - 698
  • [7] Non-invasive Glucose Monitoring System Utilizing Near-Infrared Technology
    Duc Trinh-Minh Dinh
    Viet Anh Truong
    An Nhu-Phu Tran
    Hieu Xuan Le
    Hien Thi-Thu Pham
    7TH INTERNATIONAL CONFERENCE ON THE DEVELOPMENT OF BIOMEDICAL ENGINEERING IN VIETNAM (BME7): TRANSLATIONAL HEALTH SCIENCE AND TECHNOLOGY FOR DEVELOPING COUNTRIES, 2020, 69 : 401 - 405
  • [8] Design of non-invasive glucose meter using near-infrared technique
    Saleh G.
    Alkaabi F.
    Al-Hajhouj N.
    Al-Towailib F.
    Al-Hamza S.
    Journal of Medical Engineering and Technology, 2018, 42 (02): : 140 - 147
  • [9] Non-invasive tracking and monitoring glucose content using near infrared spectroscopy
    Tamilselvi, M.
    Ramkumar, G.
    2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND COMPUTING RESEARCH (ICCIC), 2015, : 847 - 849
  • [10] Design and Implementation of a Non-Invasive RF Device to Measure Glucose in Blood
    Gelosi, Ivan Exequiel
    Ribas, Ramiro Avalos
    Uriz, Alejandro Jose
    Moreira, Jorge Castifieira
    Fuentes, Nora
    IEEE LATIN AMERICA TRANSACTIONS, 2022, 20 (05) : 813 - 822