Characterization of 4x4 ch MPPC array in scintillation spectrometry

被引:14
作者
Grodzicka, M. [1 ]
Moszynski, M. [1 ]
Szczesniak, T. [1 ]
Szawlowski, M. [1 ]
Baszak, J.
机构
[1] Natl Ctr Nucl Res, PL-05400 Otwock, Poland
来源
JOURNAL OF INSTRUMENTATION | 2013年 / 8卷
关键词
Photon detectors for UV; visible and IR photons (solid-state) (PIN diodes; APDs; Si-PMTs; G-APDs; CCDs; EBCCDs; EMCCDs etc); Gamma detectors; PHOTOMULTIPLIERS;
D O I
10.1088/1748-0221/8/09/P09020
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The aim of this work is an evaluation of MPPC array characteristics in application for scintillation light readout in gamma-ray spectrometry. Hamamatsu MPPC array of 4 x 4 channels format and total area of 12 x 12mm(2) was used as a light readout device with CsI: Tl, BGO, LSO, LaBr3, NaI: Tl, CsI: Na, LaCl3, CaF2: Eu, and CdWO4 scintillators. The measurements presented in this work covered: measurements of the breakdown voltage for each channel of the MPPC array, selection of the optimum operating voltage, evaluation of the linearity range of MPPC response for each of the used crystals, measurements of the number of photoelectrons per MeV and measurements of the energy resolution for 661.6 keV gamma-rays from Cs-137. The results of the energy resolution and number of photoelectrons obtained with the tested MPPC and nine scintillators were compared to those obtained for the same scintillators with XP2020Q and XP5212 PMTs. The energy resolution data for 661.6 keV gamma-rays, obtained with 12 x 12 x 12mm(3) CsI: Tl, LSO and BGO scintillators coupled to the tested MPPC are equal to: 6.4%, 9.4% and 9.5%, respectively, and are close to the results obtained for the same scintillators coupled to the XP2020Q PMT (6.6%, 9.4% and 10.5%, respectively). The study showed that light readout by means of an MPPC array produces comparable or even slightly better (in the case of a proper match of the MPPC and the scintillator optical surface) results than the XP2020Q PMT readout.
引用
收藏
页数:23
相关论文
共 17 条
[1]   YSO, LSO, GSO and LGSO. A study of energy resolution and nonproportionality. [J].
Balcerzyk, M ;
Moszynski, M ;
Kapusta, M ;
Wolski, D ;
Pawelke, J ;
Melcher, CL .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) :1319-1323
[2]  
Bertolaccini M., 1968, Nucl. Electr. Symp., V1, P1
[3]   Silicon photomultiplier and its possible applications [J].
Buzhan, P ;
Dolgoshein, B ;
Filatov, L ;
Ilyin, A ;
Kantzerov, V ;
Kaplin, V ;
Karakash, A ;
Kayumov, F ;
Klemin, S ;
Popova, E ;
Smirnov, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 504 (1-3) :48-52
[4]   Characterisation studies of silicon photomultipliers [J].
Eckert, Patrick ;
Schultz-Coulon, Hans-Christian ;
Shen, Wei ;
Stamen, Rainer ;
Tadday, Alexander .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 620 (2-3) :217-226
[5]   MPPC Array in the Readout of CsI:Tl, LSO:Ce:Ca, LaBr3:Ce, and BGO Scintillators [J].
Grodzicka, M. ;
Moszynski, M. ;
Szczesniak, T. ;
Szawlowski, M. ;
Wolski, D. ;
Baszak, J. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (06) :3294-3303
[6]  
Grodzicka M., 2013, JINST, V8
[7]  
Grodzicka M., CHARACTERIZATI UNPUB
[8]   TUKAN - An 8K pulse height analyzer and multi-channel scaler with a PCI or a USB interface [J].
Guzik, Z ;
Borsuk, S ;
Traczyk, K ;
Plominski, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :231-235
[9]  
Moszynski M., 2005, Proceedings of the SPIE - The International Society for Optical Engineering, V5922, P592205, DOI 10.1117/12.622316
[10]   Evaluation of new photonis XP1472 nine-channel photomultiplier [J].
Moszynski, M ;
Kapusta, A ;
Wolski, D ;
Balcerzyk, M ;
Syntfeld, A ;
Fontaine, C ;
Lavoute, P ;
Bascle, P ;
Moussant, C ;
Flyckt, SO .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) :1027-1032