Skeletal muscle power and fatigue at the tolerable limit of ramp-incremental exercise in COPD

被引:20
作者
Cannon, Daniel T. [1 ,2 ]
Coelho, Ana Claudia [1 ,3 ]
Cao, Robert [1 ]
Cheng, Andrew [1 ]
Porszasz, Janos [1 ]
Casaburi, Richard [1 ]
Rossiter, Harry B. [1 ,4 ]
机构
[1] Harbor UCLA, Med Ctr, Los Angeles Biomed Res Inst, Div Resp & Crit Care Physiol & Med,Rehabil Clini, Torrance, CA USA
[2] San Diego State Univ, Sch Exercise & Nutr Sci, San Diego, CA 92182 USA
[3] Univ Fed Rio Grande do Sul, Hosp Clin Porto Alegre, Dept Pulmonol, Porto Alegre, RS, Brazil
[4] Univ Leeds, Sch Biomed Sci, Fac Biol Sci, Leeds, W Yorkshire, England
关键词
isokinetic; chronic obstructive pulmonary disease; exercise intolerance; OBSTRUCTIVE PULMONARY-DISEASE; COMMON SYNAPTIC INPUT; PHYSICAL-ACTIVITY; CYCLE EXERCISE; MOTOR-NEURONS; TASK FAILURE; PERFORMANCE; ENDURANCE; REHABILITATION; VENTILATION;
D O I
10.1152/japplphysiol.00660.2016
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Muscle fatigue (a reduced power for a given activation) is common following exercise in chronic obstructive pulmonary disease (COPD). Whether muscle fatigue, and reduced maximal voluntary locomotor power, are sufficient to limit whole body exercise in COPD is unknown. We hypothesized in COPD: 1) exercise is terminated with a locomotor muscle power reserve; 2) reduction in maximal locomotor power is related to ventilatory limitation; and 3) muscle fatigue at intolerance is less than age-matched controls. We used a rapid switch from hyperbolic to isokinetic cycling to measure the decline in peak isokinetic power at the limit of incremental exercise ("performance fatigue") in 13 COPD patients (FEV1 49 +/- 17% pred) and 12 controls. By establishing the baseline relationship between muscle activity and isokinetic power, we apportioned performance fatigue into the reduction in muscle activation and muscle fatigue. Peak isokinetic power at intolerance was similar to 130% of peak incremental power in controls (274 +/- 73 vs. 212 +/- 84 W, P < 0.05), but similar to 260% in COPD patients (187 +/- 141 vs. 72 +/- 34 W, P<0.05), greater than controls (P <0.05). Muscle fatigue as a fraction of baseline peak isokinetic power was not different in COPD patients vs. controls (0.11 +/- 0.20 vs. 0.19 +/- 0.11). Baseline to intolerance, the median frequency of maximal isokinetic muscle activity, was unchanged in COPD patients but reduced in controls (+ 4.3 +/- 11.6 vs. -5.5 +/- 7.6%, P<0.05). Performance fatigue as a fraction of peak incremental power was greater in COPD vs. controls and related to resting (FEV1/FVC) and peak exercise (V. E/maximal voluntary ventilation) pulmonary function (r(2) +/- 0.47 and 0.55, P<0.05). COPD patients are more fatigable than controls, but this fatigue is insufficient to constrain locomotor power and define exercise intolerance.
引用
收藏
页码:1365 / 1373
页数:9
相关论文
共 51 条
[11]   STANDARDIZATION OF THE MEASUREMENT OF TRANSFER-FACTOR (DIFFUSING-CAPACITY) - REPORT WORKING PARTY STANDARDIZATION OF LUNG-FUNCTION TESTS EUROPEAN-COMMUNITY FOR STEEL AND COAL - OFFICIAL STATEMENT OF THE EUROPEAN RESPIRATORY SOCIETY [J].
COTES, JE ;
CHINN, DJ ;
QUANJER, PH ;
ROCA, J ;
YERNAULT, JC .
EUROPEAN RESPIRATORY JOURNAL, 1993, 6 :41-52
[12]   The major limitation to exercise performance in COPD is lower limb muscle dysfunction [J].
Debigare, Richard ;
Maltais, Francois .
JOURNAL OF APPLIED PHYSIOLOGY, 2008, 105 (02) :751-753
[13]   Neuromuscular adjustments that constrain submaximal EMG amplitude at task failure of sustained isometric contractions [J].
Dideriksen, Jakob L. ;
Enoka, Roger M. ;
Farina, Dario .
JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (02) :485-494
[14]   POWER OUTPUT AND WORK IN DIFFERENT MUSCLE GROUPS DURING ERGOMETER CYCLING [J].
ERICSON, MO ;
BRATT, A ;
NISELL, R ;
ARBORELIUS, UP ;
EKHOLM, J .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1986, 55 (03) :229-235
[15]   Common Synaptic Input to Motor Neurons, Motor Unit Synchronization, and Force Control [J].
Farina, Dario ;
Negro, Francesco .
EXERCISE AND SPORT SCIENCES REVIEWS, 2015, 43 (01) :23-33
[16]   Power-Velocity and Power-Efficiency Implications in the Limitation of Ramp Incremental Cycle Ergometry: Reply to Morales-Alamo et al. [J].
Ferguson, Carrie ;
Cannon, Daniel T. ;
Wylde, Lindsey A. ;
Benson, Alan P. ;
Rossiter, Harry B. .
JOURNAL OF APPLIED PHYSIOLOGY, 2016, 120 (04) :477-477
[17]   No reserve in isokinetic cycling power at intolerance during ramp incremental exercise in endurance-trained men [J].
Ferguson, Carrie ;
Wylde, Lindsey A. ;
Benson, Alan P. ;
Cannon, Daniel T. ;
Rossiter, Harry B. .
JOURNAL OF APPLIED PHYSIOLOGY, 2016, 120 (01) :70-77
[18]   Influences of Spinal Anesthesia on Exercise Tolerance in Patients with Chronic Obstructive Pulmonary Disease [J].
Gagnon, Philippe ;
Bussieres, Jean S. ;
Ribeiro, Fernanda ;
Gagnon, Serge L. ;
Saey, Didier ;
Gagne, Nathalie ;
Provencher, Steeve ;
Maltais, Francois .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2012, 186 (07) :606-615
[19]   Absence of viscerosomatic inhibition with injections of lobeline designed to activate human pulmonary C fibres [J].
Gandevia, SC ;
Butler, JE ;
Taylor, JL ;
Crawford, MR .
JOURNAL OF PHYSIOLOGY-LONDON, 1998, 511 (01) :289-300
[20]   Regular physical activity reduces hospital admission and mortality in chronic obstructive pulmonary disease:: a population based cohort study [J].
Garcia-Aymerich, J. ;
Lange, P. ;
Benet, M. ;
Schnohr, P. ;
Anto, J. M. .
THORAX, 2006, 61 (09) :772-778