Flammability of Surgical Drapes and Materials in Varying Concentrations of Oxygen

被引:28
|
作者
Culp, William C., Jr. [1 ]
Kimbrough, Bradly A. [1 ]
Luna, Sarah [1 ]
机构
[1] Texas A&M Univ, Hlth Sci Ctr, Coll Med, Scott & White Hosp,Dept Anesthesiol, Temple, TX 76508 USA
基金
美国国家科学基金会;
关键词
OPERATING-ROOM; FIRES; SURGERY;
D O I
10.1097/ALN.0b013e3182a35303
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Over 600 operating room fires occur annually although many cases go unreported. Over 81% of operating room fires involve surgical drapes, yet limited data exist on the differing degrees of flammability of drapes and other surgical fuel sources in varying oxygen concentrations. The purpose of this study is to assess the flammability characteristics of fuels in the operating room under varying oxygen concentrations. Methods: Five fuel sources were analyzed in three levels of oxygen: 21%, 50%, and 100%. Three test samples of each material were burned in a manner similar to that established by the Consumer Product Safety Commission. Time to sample ignition and time to complete burn were measured with video analysis. Results: The median [minimum, maximum] ignition time in 21% oxygen was 0.9 s [0.3, 1.9], in 50% oxygen 0.4 s [0.1, 1.2], and in 100% oxygen 0.2 s [0.0, 0.4]. The median burn time in 21% oxygen was 20.4 s [7.8, 33.5], in 50% oxygen 3.1 s [1.4, 8.1], and in 100% oxygen 1.7 s [0.6, 2.7]. Time to ignite and total burn times decreased as oxygen concentration increased (P < 0.001). Flammability characteristics differed by material and oxygen concentration. Utility drapes and surgical gowns did not support combustion in room air, whereas other materials quickly ignited. Flash fires were detected on woven cotton materials in oxygen-enriched environments. Conclusions: Operating room personnel should be aware that common materials in the operating room support rapid combustion in oxygen-enriched environments. The risk of ignition and speed of fire propagation increase as oxygen exposure increases. Advances in material science may reduce perioperative fire risk.
引用
收藏
页码:770 / 776
页数:7
相关论文
共 50 条
  • [41] Do nonwoven gowns and drapes reduce surgical infections?
    1600, Elsevier Science Ltd, Oxford, Engl (04):
  • [42] ROLE OF IMPERVIOUS DRAPES AND GOWNS IN PREVENTING SURGICAL INFECTION
    DINEEN, P
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1973, (96) : 210 - 212
  • [43] Skin Avulsion Injuries with Use of Adhesive Surgical Drapes
    Liu, Yitao
    Nandi, Sumon
    Skaife, Tyler
    Lang, Jason
    Bono, James V.
    JOURNAL OF KNEE SURGERY, 2013, 26 : S120 - S122
  • [44] Hygiene at the operating table. Skin antisepsis, surgical drapes and surgical gloves
    Kramer, A.
    TRAUMA UND BERUFSKRANKHEIT, 2012, 14 : 105 - 109
  • [45] OXYGEN INDEX FLAMMABILITY TEST
    ISAACS, JL
    MODERN PLASTICS, 1970, 47 (03): : 124 - &
  • [46] Influence of skin preparation on surgical site infection and lift of adhesive surgical drapes
    Gant, James W.
    Collins, Josh E.
    Miller, Zachary A.
    Einsporn, Richard L.
    VETERINARY SURGERY, 2025, 54 (03) : 478 - 485
  • [47] Flammability properties for charring materials
    Delichatsios, M
    Paroz, B
    Bhargava, A
    FIRE SAFETY JOURNAL, 2003, 38 (03) : 219 - 228
  • [48] FLAMMABILITY INDEX OF POLYMERIC MATERIALS
    KISHORE, K
    DAS, KM
    COLLOID AND POLYMER SCIENCE, 1980, 258 (01) : 95 - 98
  • [49] ASSESSMENT OF FLAMMABILITY OF TEXTILE MATERIALS
    JONES, EB
    CHEMISTRY & INDUSTRY, 1965, (29) : 1289 - &
  • [50] Clear Surgical Drapes: A Technique to Facilitate the "Natural Cesarean Delivery"
    Camann, William
    Trainor, Kathleen
    ANESTHESIA AND ANALGESIA, 2012, 115 (04): : 981 - 982