Flammability of Surgical Drapes and Materials in Varying Concentrations of Oxygen

被引:28
|
作者
Culp, William C., Jr. [1 ]
Kimbrough, Bradly A. [1 ]
Luna, Sarah [1 ]
机构
[1] Texas A&M Univ, Hlth Sci Ctr, Coll Med, Scott & White Hosp,Dept Anesthesiol, Temple, TX 76508 USA
基金
美国国家科学基金会;
关键词
OPERATING-ROOM; FIRES; SURGERY;
D O I
10.1097/ALN.0b013e3182a35303
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Over 600 operating room fires occur annually although many cases go unreported. Over 81% of operating room fires involve surgical drapes, yet limited data exist on the differing degrees of flammability of drapes and other surgical fuel sources in varying oxygen concentrations. The purpose of this study is to assess the flammability characteristics of fuels in the operating room under varying oxygen concentrations. Methods: Five fuel sources were analyzed in three levels of oxygen: 21%, 50%, and 100%. Three test samples of each material were burned in a manner similar to that established by the Consumer Product Safety Commission. Time to sample ignition and time to complete burn were measured with video analysis. Results: The median [minimum, maximum] ignition time in 21% oxygen was 0.9 s [0.3, 1.9], in 50% oxygen 0.4 s [0.1, 1.2], and in 100% oxygen 0.2 s [0.0, 0.4]. The median burn time in 21% oxygen was 20.4 s [7.8, 33.5], in 50% oxygen 3.1 s [1.4, 8.1], and in 100% oxygen 1.7 s [0.6, 2.7]. Time to ignite and total burn times decreased as oxygen concentration increased (P < 0.001). Flammability characteristics differed by material and oxygen concentration. Utility drapes and surgical gowns did not support combustion in room air, whereas other materials quickly ignited. Flash fires were detected on woven cotton materials in oxygen-enriched environments. Conclusions: Operating room personnel should be aware that common materials in the operating room support rapid combustion in oxygen-enriched environments. The risk of ignition and speed of fire propagation increase as oxygen exposure increases. Advances in material science may reduce perioperative fire risk.
引用
收藏
页码:770 / 776
页数:7
相关论文
共 50 条
  • [1] FLAMMABILITY OF DISPOSABLE SURGICAL DRAPES
    JOHNSON, RM
    SMITH, CV
    LEGGETT, K
    ARCHIVES OF OPHTHALMOLOGY, 1976, 94 (08) : 1327 - 1329
  • [2] Flammability of drapes and other fuel sources in the OR
    不详
    AORN JOURNAL, 2021, 114 (02) : P15 - P15
  • [3] SURGICAL DRAPES
    COLE, WH
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1962, 181 (02): : 176 - &
  • [4] Operating Room Fires: Drapes and Oxygen Contamination of the Surgical Field
    Webb, Kenisha L.
    Culp, William C., Jr.
    ANESTHESIA AND ANALGESIA, 2017, 124 : 136 - 137
  • [5] Laser ignition of surgical drapes in an oxygen enriched atmosphere.
    Galapo, S
    Wolf, GL
    Sidebotham, GW
    Cohen, D
    ANESTHESIOLOGY, 1998, 89 (3A) : U428 - U428
  • [6] Flammability of combustible materials in reduced oxygen environment
    Xin, Yibing
    Khan, Mohammed M.
    FIRE SAFETY JOURNAL, 2007, 42 (08) : 536 - 547
  • [7] OXYGEN INDEX AND FLAMMABILITY OF POLYMERIC MATERIALS - A REVIEW
    KISHORE, K
    MOHANDAS, K
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 1983, 42 (02): : 76 - 81
  • [8] FLAMMABILITY OF DRAPE MATERIALS IN NITROUS OXIDE AND OXYGEN
    CAMERON, BGD
    INGRAM, GS
    ANAESTHESIA, 1971, 26 (03) : 281 - &
  • [9] TRANSPARENT SURGICAL DRAPES
    REYNOLDS, RN
    ANESTHESIOLOGY, 1973, 38 (05) : 496 - 497
  • [10] Attaching instruments on surgical drapes
    Kuwahara, RT
    Garcia, C
    DERMATOLOGIC SURGERY, 2002, 28 (06) : 542 - 542