Improving the Sensitivity of Solid-Contact Ion-Selective Electrodes by Using Coulometric Signal Transduction

被引:79
作者
Han, Tingting [1 ]
Mattinen, Ulriika [1 ]
Bobacka, Johan [1 ]
机构
[1] Abo Akad Univ, Johan Gadolin Proc Chem Ctr, Analyt Chem Lab, Biskopsgatan 8, FI-20500 Turku, Finland
基金
芬兰科学院;
关键词
solid-contact ISE; coulometric transduction; high sensitivity; impedance; pH; seawater; BULK OPTODES; SEAWATER; SENSOR;
D O I
10.1021/acssensors.8b01649
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A fundamental limitation of potentiometric ion sensors is their relatively low sensitivity due to the logarithmic dependence between potential and activity. Here we address this issue by exploring a recently developed coulometric transduction method for solid-contact ion-selective electrodes (SCISEs). Spin-coated thin-layer ion-selective membranes are used to lower the membrane resistance and shorten the response time of the SCISEs. When using coulometric transduction, an optimized design of the K+-SCISE is able to detect a concentration change of 5 mu M at a concentration level of 5 mM, corresponding to a 0.1% change in K+ activity. This indicates that SCISEs can provide extremely high sensitivity when employing coulometric transduction. Impedance measurements show that the coulometric transduction process for the K+-SCISE is limited by diffusion even for very thin ion-selective membranes. On the other hand, the H+-SCISE shows a low impedance and a fast coulometric response that is related to the high mobility of H+ in the H+-selective polymeric membrane as well as in the solid contact layer. The coulometric transduction method was used to detect small changes of pH in seawater and found to improve the sensitivity compared to classical potentiometry. The coulometric method was briefly tested also for determining activity changes of K+ in a serum sample.
引用
收藏
页码:900 / 906
页数:13
相关论文
共 19 条
[1]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[2]   Potentiometric ion sensors [J].
Bobacka, Johan ;
Ivaska, Ari ;
Lewenstam, Andrzej .
CHEMICAL REVIEWS, 2008, 108 (02) :329-351
[3]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[4]   In Situ Detection of Species Relevant to the Carbon Cycle in Seawater with Submersible Potentiometric Probes [J].
Cuartero, Maria ;
Pankratova, Nadezda ;
Cherubini, Thomas ;
Crespo, Gaston A. ;
Massa, Francesco ;
Confalonieri, Fabio ;
Bakker, Eric .
ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS, 2017, 4 (10) :410-415
[5]   Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis [J].
Gao, Wei ;
Emaminejad, Sam ;
Nyein, Hnin Yin Yin ;
Challa, Samyuktha ;
Chen, Kevin ;
Peck, Austin ;
Fahad, Hossain M. ;
Ota, Hiroki ;
Shiraki, Hiroshi ;
Kiriya, Daisuke ;
Lien, Der-Hsien ;
Brooks, George A. ;
Davis, Ronald W. ;
Javey, Ali .
NATURE, 2016, 529 (7587) :509-+
[6]   Influence of Electrode Geometry on the Response of Solid-Contact Ion-Selective Electrodes when Utilizing a New Coulometric Signal Readout Method [J].
Han, Tingting ;
Vanamo, Ulriika ;
Bobacka, Johan .
CHEMELECTROCHEM, 2016, 3 (12) :2071-2077
[7]   Novel Ion-to-Electron Transduction Principle for Solid-Contact ISEs [J].
Hupa, Elisa ;
Vanamo, Ulriika ;
Bobacka, Johan .
ELECTROANALYSIS, 2015, 27 (03) :591-594
[8]   Capacitive Model for Coulometric Readout of Ion-Selective Electrodes [J].
Jarolimova, Zdenka ;
Han, Tingting ;
Mattinen, Ulriika ;
Bobacka, Johan ;
Bakker, Eric .
ANALYTICAL CHEMISTRY, 2018, 90 (14) :8700-8707
[9]   Spectroscopic in situ imaging of acid coextraction processes in solvent polymeric ion-selective electrode and optode membranes [J].
Lindner, E ;
Zwickl, T ;
Bakker, E ;
Lan, BTT ;
Tóth, K ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 1998, 70 (06) :1176-1181
[10]   Potentiometry at trace levels in confined samples: Ion-selective electrodes with subfemtomole detection limits [J].
Malon, Adam ;
Vigassy, Tamas ;
Bakker, Eric ;
Pretsch, Erno .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (25) :8154-8155