Dual-Energy Computed Tomography in Genitourinary Imaging

被引:16
作者
Mileto, Achille [1 ]
Marin, Daniele [2 ]
机构
[1] Univ Washington, Dept Radiol, Sch Med, Box 357115,1959 Northeast Pacific St, Seattle, WA 98195 USA
[2] Duke Univ, Dept Radiol, Med Ctr, Box 3808,Erwin Rd, Durham, NC 27710 USA
关键词
CT; Dual-energy CT; Genitourinary imaging; Renal stone; Renal mass; Radiation dose; RENAL-CELL CARCINOMA; MULTIDETECTOR ROW CT; VIRTUAL NONENHANCED IMAGES; IODINE QUANTIFICATION; ADRENAL NODULES; URIC-ACID; IN-VITRO; RADIOFREQUENCY ABLATION; CYST PSEUDOENHANCEMENT; DIAGNOSTIC PERFORMANCE;
D O I
10.1016/j.rcl.2016.10.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Reignited by innovations in scanner engineering and software design, dual-energy computed tomography (CT) has come back into the clinical radiology arena in the last decade. Possibilities for noninvasive in vivo characterization of genitourinary disease, especially for renal stones and renal masses, have become the pinnacle offerings of dual-energy CT for body imaging in clinical practice. This article renders a state-of-the-art review on clinical applications of dual-energy CT in genitourinary imaging.
引用
收藏
页码:373 / +
页数:20
相关论文
共 70 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]   Dual energy CT in patients with polycystic kidney disease [J].
Arndt, Nikolaus ;
Staehler, Michael ;
Siegert, Sabine ;
Reiser, Maximilian F. ;
Graser, Anno .
EUROPEAN RADIOLOGY, 2012, 22 (10) :2125-2129
[3]   Single-phase dual-energy CT urography in the evaluation of haematuria [J].
Ascenti, G. ;
Mileto, A. ;
Gaeta, M. ;
Blandino, A. ;
Mazziotti, S. ;
Scribano, E. .
CLINICAL RADIOLOGY, 2013, 68 (02) :E87-E94
[4]   Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements [J].
Ascenti, Giorgio ;
Mileto, Achille ;
Krauss, Bernhard ;
Gaeta, Michele ;
Blandino, Alfredo ;
Scribano, Emanuele ;
Settineri, Nicola ;
Mazziotti, Silvio .
EUROPEAN RADIOLOGY, 2013, 23 (08) :2288-2295
[5]   Dual-Source Dual-Energy CT Evaluation of Complex Cystic Renal Masses [J].
Ascenti, Giorgio ;
Mazziotti, Silvio ;
Mileto, Achille ;
Racchiusa, Sergio ;
Donato, Rocco ;
Settineri, Nicola ;
Gaeta, Michele .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :1026-1034
[6]   Stone-Targeted Dual-Energy CT: A New Diagnostic Approach to Urinary Calculosis [J].
Ascenti, Giorgio ;
Siragusa, Carmelo ;
Racchiusa, Sergio ;
Ielo, Isidora ;
Privitera, Giambattista ;
Midili, Federica ;
Mazziotti, Silvio .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (04) :953-958
[7]   Percutaneous Ablation of Renal Masses Measuring 3.0 cm and Smaller: Comparative Local Control and Complications After Radiofrequency Ablation and Cryoablation [J].
Atwell, Thomas D. ;
Schmit, Grant D. ;
Boorjian, Stephen A. ;
Mandrekar, Jay ;
Kurup, A. Nicholas ;
Weisbrod, Adam J. ;
Chow, George K. ;
Leibovich, Bradley C. ;
Callstrom, Matthew R. ;
Patterson, David E. ;
Lohse, Christine M. ;
Thompson, R. Houston .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (02) :461-466
[8]  
Blake MA, 2011, RADIOGRAPHICS, V31, P1047, DOI 10.1148/rg.314105159
[9]   Incidental Adrenal Lesions: Principles, Techniques, and Algorithms for Imaging Characterization [J].
Boland, Giles W. L. ;
Blake, Michael A. ;
Hahn, Peter F. ;
Mayo-Smith, William W. .
RADIOLOGY, 2008, 249 (03) :756-775
[10]   Feasibility of virtual nonenhanced images derived from single-source fast kVp-switching dual-energy CT in evaluating gastric tumors [J].
Chai, Yaru ;
Xing, Jingjing ;
Gao, Jianbo ;
Lv, Peijie ;
Liang, Pan ;
Liu, Jie ;
Guo, Ying .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (02) :366-372