Efficacy of corneal tomography parameters and biomechanical characteristic in keratoconus detection

被引:20
作者
Hosseini, Seyed Mandi Ahmadi [1 ,2 ]
Abolbashari, Fereshteh [1 ,2 ]
Niyazmand, Harried [1 ,2 ]
Sedaghat, Mohammad Reza [1 ,2 ]
机构
[1] Mashhad Univ Med Sci, Refract Errors Res Ctr, Sch Paramed Sci, Mashhad, Iran
[2] Mashhad Med Univ, Dept Ophthalmol, Mashhad, Iran
关键词
Keratoconus; Corneal thickness; Corneal volume; Corneal hysteresis; Corneal resistance factor; OCULAR RESPONSE ANALYZER; REFRACTIVE SURGERY; NORMAL EYES; ORIENTATION;
D O I
10.1016/j.clae.2013.07.007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To determine the efficacy of corneal thickness parameters and corneal biomechanical properties (CBPs) in discriminating between normal and keratoconus eyes. Method: After performing a comprehensive ophthalmic examination, 50 mild to moderate keratoconus and 50 age and sex matched myopic astigmatism eyes were prospectively included in the study. The corneal topographic maps and CBP were obtained by Pentacam and Ocular response analyser, respectively. Central corneal thickness (CCT), thinnest corneal thickness (TCT), corneal thickness (CT) and percentage thickness increase (PTI) at 1,3 and 5 mm from the thinnest point and corneal volume (CV) at 3, 5, 7 and 10 centred on thinnest point, corneal hysteresis (CH) and corneal resistance factor (CRF) were recorded. Independent t-test and receiver operating characteristic (ROC) were done with SPSS software (version 15.0, SPSS, Inc.). Results: CCT, TCT, CT at 1, 3 and 5, CV at 3, 5, 7 and 10 mm, CH and CRF were significantly lower in keratoconus eyes compared to controls (p<0.001). In addition, PT! at 1,3 and 5 mm from the thinnest point showed significantly higher values in keratoconus group. ROC analysis demonstrated good predictive accuracy for cut-off point values. However, the centrally located indices had higher predictive accuracy compared to the peripherally located indices. Conclusion: Although good sensitivity and specificity were found for the mentioned parameters, the centrally located indices had higher predictive accuracy compared to peripherally located indices. It is suggested to use a combination of corneal pachymetry together with CBP for more accurate detection of keratoconus. (C) 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 28 条
[1]   Anterior segment characteristics of keratoconus eyes in a sample of Asian population [J].
Abolbashari, Fereshteh ;
Mohidin, Norhani ;
Hosseini, Seyed Mahdi Ahmadi ;
Ali, Bariah Mohd ;
Retnasabapathy, Shamala .
CONTACT LENS & ANTERIOR EYE, 2013, 36 (04) :191-195
[2]  
Ambrosio Jr R, 2006, J CATARACT REFR SURG, V32, P1851
[3]  
Ambrosio R, 2003, J REFRACT SURG, V19, P24
[4]   Ectasia after laser in situ keratomileusis [J].
Binder, PS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (12) :2419-2429
[5]   HISTOPATHOLOGY OF KERATOCONUS [J].
CHI, HH ;
KATZIN, HM ;
TENG, CC .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1956, 42 (06) :847-860
[6]  
Chopra Ira, 2005, Clin Exp Optom, V88, P146
[7]  
Daxer A, 1997, INVEST OPHTH VIS SCI, V38, P121
[8]   Biomechanics and wound healing in the cornea [J].
Dupps, William J., Jr. ;
Wilson, Steven E. .
EXPERIMENTAL EYE RESEARCH, 2006, 83 (04) :709-720
[9]   Ability of corneal biomechanical metrics and anterior segment data in the differentiation of keratoconus and healthy corneas [J].
Fontes, Bruno Machado ;
Ambrosio, Renato, Jr. ;
Jardim, Daniela ;
Velarde, Guillermo Coca ;
Nose, Walton .
ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2010, 73 (04) :333-337
[10]   Corneal thickness and volume in subclinical and clinical keratoconus [J].
Hosseini, Seyed Mahdi Ahmadi ;
Mohidin, Norhani ;
Abolbashari, Fereshteh ;
Mohd-Ali, Bariah ;
Santhirathelagan, Chandramalar T. .
INTERNATIONAL OPHTHALMOLOGY, 2013, 33 (02) :139-145