Post-repair flexural performance of corrosion-damaged beams rehabilitated with fabric-reinforced cementitious matrix (FRCM)

被引:42
作者
Elghazy, Mohammed [1 ]
El Refai, Ahmed [1 ]
Ebead, Usama [2 ]
Nanni, Antonio [3 ]
机构
[1] Laval Univ, Dept Civil & Water Engn, Quebec City, PQ G1V 0A6, Canada
[2] Qatar Univ, Coll Engn, Dept Civil & Architectural Engn, POB 2713, Doha, Qatar
[3] Univ Miami, Dept Civil Architectural & Environm Engn, Coral Gables, FL 33124 USA
关键词
Corrosion; Fabric-reinforced cementitious matrix; Flexure; Reinforced concrete; Repair; Strengthening; Rehabilitation; Durability; Long-term performance; RC BEAMS; CONCRETE; FRP; CAPACITY;
D O I
10.1016/j.conbuildmat.2018.01.128
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of a research program examining the post-repair flexural response of corrosion-damaged reinforced concrete (RC) beams repaired with different FRCM systems. A total of nine RC beams were tested, including two beams that were neither corroded nor repaired, one beam that was corroded and not repaired, and six corroded-repaired beams that were prepared in two phases. Beams of phase I were subjected to an accelerated corrosion process for 210 days before being repaired whereas beams of phase II were initially subjected to accelerated corrosion for 70 days, then repaired and exposed to further corrosion for 140 days. Flexural test results showed that exposing the FRCM-repaired beams to corrosion after repair resulted in 23% reduction in steel mass loss. The use of U-shaped FRCM layers was more efficient in reducing the corrosion rate and increasing the ultimate strength of the repaired beams than the end-anchored FRCM layers. The PBO FRCM-repaired beams showed lower post-yielding stiffness and more ductility at failure than those of their carbon FRCM-repaired counterparts. Beams that experienced post-repair corrosive environment showed load-carrying capacities that ranged between 14 and 65% above those of the virgin beam. ACI 549.4R-13 provisions conservatively predict the ultimate capacities of the FRCM-repaired beams exposed to post-repair corrosive environment. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:732 / 744
页数:13
相关论文
共 28 条
  • [1] Al-Salloum Y.A., 2012, J COMPOS CONSTR
  • [2] Effect of degree of corrosion on the properties of reinforcing steel bars
    Almusallam, AA
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2001, 15 (08) : 361 - 368
  • [3] [Anonymous], 2013, 549 ACI COMM
  • [4] [Anonymous], 2017, ASTM G1-03, DOI DOI 10.1520/G0001-03R11.2
  • [5] [Anonymous], J COMPOS CONSTR
  • [6] [Anonymous], 2014, 31819 ACI, DOI DOI 10.14359/51716937
  • [7] Flexural strength of corroded reinforced concrete beams
    Azad, A. K.
    Ahmad, S.
    Al-Gohi, B. H. A.
    [J]. MAGAZINE OF CONCRETE RESEARCH, 2010, 62 (06) : 405 - 414
  • [8] Babaeidarabad S., 2014, J COMPOS CONSTR
  • [9] Strengthening of shear critical RC beams with various FRP systems
    Baggio, Daniel
    Soudki, Khaled
    Noel, Martin
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2014, 66 : 634 - 644
  • [10] Bournas DA, 2007, ACI STRUCT J, V104, P740