Transoccipital power-based color-coded duplex sonography of cerebral sinuses and veins

被引:45
|
作者
Baumgartner, RW [1 ]
Nirkko, AC [1 ]
Muri, RM [1 ]
Gonner, F [1 ]
机构
[1] UNIV BERN,INSELSPITAL,DEPT NEUROL,CH-3010 BERN,SWITZERLAND
关键词
cerebral veins; Doppler; duplex scanning; ultrasonics;
D O I
10.1161/01.STR.28.7.1319
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose Power-based transcranial color-coded duplex sonography is a new development for cerebrovascular imaging that is suited for detection of slow velocities. The purpose of this study was to evaluate the ability of this technique to detect cerebral sinuses and veins by means of the occipital window and to provide reference data. Methods The straight and inferior sagittal sinuses, great and internal cerebral veins, and basal veins were insonated in 120 normal subjects. The number of identified vessels. peak systolic (PSV) and end-diastolic (PDV) velocities, and resistance indices were determined. Results In subjects aged 20 to 59 years, straight sinuses were identified in 81% and great and internal cerebral veins in 34%. In subjects aged 60 to 79 years, straight sinuses were detected in 50%, great cerebral veins in 20%, and internal cerebral veins in 13%. All insonated inferior sagittal sinuses and basal veins were missed. Velocities were highest in straight sinuses (PSV, 35 [7 to 64] cm/s; PDV, 23 [2 to 43] cm/s), slower in great cerebral veins (PSV, 23 [12 to 34] cm/s; PDV, 16 [7 to 26] cm/s), and slowest in internal cerebral veins (PSV, 14 [10 to 18] cm/s; PDV, 10 [5 to 15] cm/s) (mean with 95% confidence intervals [CIs]). Straight sinus velocities decreased with age for PSV (20 to 39 years, 40 [7 to 73] cm/s; 60 to 79 years, 28 [9 to 46] cm/s; P<.01) and PDV values (20 to 39 years, 28 [4 to 52] cm/s; 60 to 79 years, 16 [5 to 26] cm/s; P<.001) (mean with 95% CIs) and were higher in women than men in the group aged 20 to 39 years. (P<.05). Resistance indices increased with age in the straight sinus (20 to 39 years, 0.30 [0.18 to 0.42]; 60 to 79 years, 0.42 [0.31 to 0.53]; P<.001) (mean with 95% CIs). Conclusions Transoccipital power-based color-coded duplex sonography enabled imaging and velocity measurements in the straight sinus of subjects aged 20 to 59 years. In elder subjects detection rate of the straight sinus decreased, and it was low for deep cerebral veins in all age groups.
引用
收藏
页码:1319 / 1323
页数:5
相关论文
共 50 条
  • [41] Comparison of transcranial color-coded sonography and magnetic resonance angiography in acute stroke
    Kenton, AR
    Martin, PJ
    Abbott, RJ
    Moody, AR
    STROKE, 1997, 28 (08) : 1601 - 1606
  • [42] Transcranial color-coded sonography to predict recurrent transient ischaemic attack/stroke
    Nasr, N.
    Ssi-Yan-Kai, G.
    Guidolin, B.
    Bonneville, F.
    Larrue, V.
    EUROPEAN JOURNAL OF NEUROLOGY, 2013, 20 (08) : 1212 - 1217
  • [43] CONTRIBUTION OF TRANSCRANIAL COLOR-CODED REAL-TIME SONOGRAPHY TO THE ETIOPATHOGENETIC CLASSIFICATION OF MIDDLE CEREBRAL-ARTERY STENOSIS
    BECKER, G
    LINDNER, A
    HOFMANN, E
    BOGDAHN, U
    JOURNAL OF CLINICAL ULTRASOUND, 1994, 22 (08) : 471 - 477
  • [44] Contrast-enhanced transcranial color-coded sonography in acute hemispheric brain infarction
    Postert, T
    Braun, B
    Meves, S
    Köster, O
    Przuntek, H
    Weber, S
    Büttner, T
    STROKE, 1999, 30 (09) : 1819 - 1826
  • [45] High prevalence of intracranial arterial stenosis among acute ischemic stroke patients in a Brazilian center: a transcranial color-coded duplex sonography study
    Rocha, Leticia Januzi de Almeida
    Zotin, Maria Clara Zanon
    Santos, Renata da Silva Almeida
    Libardi, Milena Carvalho
    Camilo, Millene Rodrigues
    Barreira, Clara Monteiro Antunes
    Pinto, Pedro Telles Cougo
    Mazim, Suleimy Cristina
    Abud, Daniel Giansante
    Neto, Octavio Marques Pontes
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2024, 82 (08) : 9 - 9
  • [46] Importance of angle correction in transcranial color-coded duplex insonation of arteries at the base of the brain
    Lepic, Toplica
    Veljancic, Dragana
    Jovanikic, Olivera
    Lepic, Milan
    Slankamenac, Petar
    Raicevic, Ranko
    VOJNOSANITETSKI PREGLED, 2015, 72 (12) : 1093 - 1097
  • [47] Feasibility and Reliability of Transcranial POCUS Color-Coded Duplex Sonography Performed by Physicians of Varied Ultrasound Experience in Diagnosing Vasospasm in Aneurysmal Subarachnoid Hemorrhage
    Connor-Schuler, Randi
    Phillips, Steven
    Kuo, Emory
    Kandiah, Prem
    Sadan, Ofer
    JOURNAL OF ULTRASOUND IN MEDICINE, 2024, 43 (02) : 315 - 322
  • [48] Transcranial Color-Coded Duplex Ultrasound for Assessing Cerebrovascular Reserve in Intracranial Dissection with Aneurysm
    Venketasubramanian, Narayanaswamy
    Tan, Andrew Eik Hock
    Neo, Wee Thong
    Taneja, Manish
    CASE REPORTS IN NEUROLOGY, 2020, 12 (SUPPL 1) : 119 - 126
  • [49] Intimal carotid artery fibromuscular dysplasia displayed by color-coded duplex sonography [Farbkodierte duplex-sonographische darstellung einer intimalen fibromuskularen dysplasie der A. carotis]
    Winter R.
    Ringleb P.
    Hacke W.
    Der Nervenarzt, 1998, 69 (10) : 905 - 908
  • [50] Echocontrast-enhanced transcranial color-coded sonography for the diagnosis of transverse sinus venous thrombosis
    Ries, S
    Steinke, W
    Neff, KW
    Hennerici, M
    STROKE, 1997, 28 (04) : 696 - 700