Assessing visitors' thermal comfort in historic museum buildings: Results from a Post-Occupancy Evaluation on a case study

被引:42
作者
Martinez-Molina, Antonio [1 ]
Boarin, Paola [2 ]
Tort-Ausina, Isabel [3 ]
Vivancos, Jose-Luis
机构
[1] Univ Politecn Valencia, Camino Vera S-N, E-46022 Valencia, Spain
[2] Univ Auckland, Fac Creat Arts & Ind CAI, Sch Architecture & Planning, 26 Symonds St, Auckland 1010, New Zealand
[3] Univ Politecn Valencia, Dept Appl Phys, Camino Vera S-N, E-46022 Valencia, Spain
关键词
Post-Occupancy Evaluation; Thermal comfort; Indoor environmental quality; Historic buildings; Museum buildings; INDOOR ENVIRONMENT; QUALITY; MICROCLIMATE; CONSERVATION; METHODOLOGY; EXHIBITION; LIBRARY;
D O I
10.1016/j.buildenv.2018.02.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Adaptive reuse of historic buildings as museums is an effective strategy for retaining heritage architectures while achieving environmental sustainability objectives. Building adaptation, retrofitting and preserving optimal environments for artwork and exhibit preservation are inherently complex, multifaceted tasks. However, indoor microclimates do not only affect collections; occupants and visitors must also be considered. The aim of this research is to explore whether artwork preservation constraints in reused historic building affect patrons. The authors thereby promote a more comprehensive approach, combining the objectives of exhibit conservation, preservation of heritage buildings and adequate indoor conditions, particularly thermal comfort. Data was gathered using the Post-Occupancy Evaluation process applied to a case study where a combination of micro climate monitoring and questionnaire surveys was carried out over a 12-month period. Results demonstrate that: i) the existing microclimate did not always provide visitors with adequate thermal conditions, showing dissatisfaction during the cooling season (July-September), with average TSV values ranging from -1.03 to -1.13; ii) TSV and PMV values were significantly divergent throughout the year, with TSV mainly included within the ( -1, 0, +1) band and PMV mainly within the (0, -2) band; and iii) questionnaires show that visitor choice of clothing is made according to outdoor conditions, with some gender-related variations in the do level (higher for women), not ensuring thermal comfort inside the museum during the warm season. Results of this research highlight the limitations of Fanger's model when applied to such typology of buildings, emphasising the need for more research in this field.
引用
收藏
页码:291 / 302
页数:12
相关论文
共 55 条
[1]   Investigation on the interaction between the outdoor environment and the indoor microclimate of a historical library [J].
Andretta, Massimo ;
Coppola, Floriana ;
Seccia, Leonardo .
JOURNAL OF CULTURAL HERITAGE, 2016, 17 :75-86
[2]  
[Anonymous], 2016, 50 YEARS LATER REVIS
[3]  
[Anonymous], 2007, Indoor Environmental Input Parameters for Design and Assessment of Energy Performance of Buildings Addressing Indoor Air Quality, Thermal Environment, Lighting and Acoustics
[4]  
[Anonymous], ICOM STAT
[5]  
[Anonymous], MICROCLIMATE CULTURA
[6]  
[Anonymous], 552013 AHRAE
[7]  
[Anonymous], 2011, WORLD MAPS KOPP GEIG
[8]  
[Anonymous], CLEVER CLIMATE CONTR
[9]  
[Anonymous], 2005, Ergonomics of the thermal environment _ Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
[10]  
[Anonymous], 55 ASHRAE