Echocardiographic Parameters of Mechanical Synchrony in Healthy Individuals

被引:45
作者
Conca, Cristina [1 ]
Faletra, Francesco Fulvio [1 ]
Miyazaki, Chinami [2 ]
Oh, Jae [2 ]
Mantovani, Antonio [1 ]
Klersy, Catherine [3 ]
Sorgente, Antonio [1 ]
Pedrazzini, Giovanni Battista [1 ]
Pasotti, Elena [1 ]
Moccetti, Tiziano [1 ]
Auricchio, Angelo [1 ]
机构
[1] Fdn Cardioctr Ticino, Div Cardiol, Lugano, Switzerland
[2] Mayo Clin, Div Cardiovasc Dis, Rochester, MN USA
[3] Policlin San Matteo, IRCCS Fdn, Res Dept, I-27100 Pavia, Italy
关键词
CARDIAC RESYNCHRONIZATION THERAPY; LEFT-VENTRICULAR DYSSYNCHRONY; HEART-FAILURE; RADIAL STRAIN; TIME; ASYNCHRONY; RECOMMENDATIONS; VELOCITY;
D O I
10.1016/j.amjcard.2008.08.039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Definition and validation of the ranges of normal values and agreement among echocardiographic measures of mechanical synchrony in healthy subjects are mostly lacking. The aims of this study were (1) to assess the ranges of normal values for 5 tissue Doppler imaging parameters, real-time 3-dimensional echocardiographic measures, and speckle-tracking measures of mechanical synchrony; (2) to evaluate interinstitutional variability; (3) to compare the ranges of normal values with those reported in previous research; and (4) to analyze the agreement among all parameters in the same healthy subject. Time to peak systolic velocity (Ts), the delay between Ts at the basal septal and lateral segments, peak velocity difference, strain derived by tissue Doppler imaging, Ts derived by tissue synchronization imaging, systolic synchrony index (SSI) derived by real-time 3-dimensional echocardiography, and longitudinal and radial strain derived by speckle tracking were prospectively collected and analyzed at 2 different institutions in 160 consecutive healthy subjects. The ranges of normal values, expressed as means +/- 2 SDs, were 30.32 +/- 29.36 ms for the SD of Ts, 15.51 +/- 99.88 ms for septal-lateral delay, 60.75 +/- 81.62 ms for peak velocity difference, 33.07 +/- 29.96 ms for tissue synchronization imaging, 34.16 +/- 23.26 ms for the SD of strain, 2.74 +/- 2.16% for SSI, 28.91 +/- 23.02 ms for the SD of longitudinal strain, and 10.4 +/- 6.31 ms for radial strain. There was large interinstitutional variability for all parameters. Three-dimensional SSI and radial strain were within the published upper range limit for healthy subjects. Ninety percent of healthy subjects were consistently classified to be synchronous by I parameter. With a composite index, more subjects than expected showed dyssynchrony (10% vs 2.5%). In conclusion, 3-dimensional SSI and radial strain were the most reproducible parameters and consistently discriminated normal healthy subjects from the cardiac resynchronization therapy volume responders. (C) 2009 Elsevier Inc. (Am J Cardiol 2009;103:136-142)
引用
收藏
页码:136 / 142
页数:7
相关论文
共 21 条
[1]   Patient selection and echocardiographic assessment of dyssynchrony in cardiac resynchronization therapy [J].
Anderson, Lisa J. ;
Miyazaki, Chinami ;
Sutherland, George R. ;
Oh, Jae K. .
CIRCULATION, 2008, 117 (15) :2009-2023
[2]   Left ventricular dyssynchrony predicts benefit of cardiac resynchronization therapy in patients with end-stage heart failure before pacemaker implantation [J].
Bax, JJ ;
Marwick, TH ;
Molhoek, SG ;
Bleeker, GB ;
van Erven, L ;
Boersma, E ;
Steendijk, P ;
van der Wall, EE ;
Schalij, MJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (10) :1238-1240
[3]   Results of the predictors of response to CRT (PROSPECT) trial [J].
Chung, Eugene S. ;
Leon, Angel R. ;
Tavazzi, Luigi ;
Sun, Jing-Ping ;
Nihoyannopoulos, Petros ;
Merlino, John ;
Abraham, William T. ;
Ghio, Stefano ;
Leclercq, Christophe ;
Bax, Jeroen J. ;
Yu, Cheuk-Man ;
Gorcsan, John, III ;
Sutton, Martin St John ;
De Sutter, Johan ;
Murillo, Jaime .
CIRCULATION, 2008, 117 (20) :2608-2616
[4]   Transmural heterogeneity of calcium activity and mechanical function in the canine left ventricle [J].
Cordeiro, JM ;
Greene, L ;
Heilmann, C ;
Antzelevitch, D ;
Antzelevitch, C .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 286 (04) :H1471-H1479
[5]   Volumetric quantification of global and regional left ventricular function from real-time three-dimensional echocardiographic images [J].
Corsi, C ;
Lang, RM ;
Veronesi, F ;
Weinert, L ;
Caiani, EG ;
MacEneaney, P ;
Lamberti, C ;
Mor-Avi, V .
CIRCULATION, 2005, 112 (08) :1161-1170
[6]   Assessment of left ventricular dyssynchrony by speckle tracking strain imaging - Comparison between longitudinal, circumferential, and radial strain in cardiac resynchronization therapy [J].
Delgado, Victoria ;
Ypenburg, Claudia ;
van Bommel, Rutger J. ;
Tops, Laurens F. ;
Mollema, Sjoerd A. ;
Marsan, Nina Ajmone ;
Bleeker, Gabe B. ;
Schalij, Martin J. ;
Bax, Jeroen J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (20) :1944-1952
[7]   Echocardiography for cardiac resynchronization therapy: Recommendations for performance and reporting - A report from the American Society of Echocardiography Dyssynchrony writing group - Endorsed by the Heart Rhythm Society [J].
Gorcsan, John, III ;
Abraham, Theodore ;
Agler, Deborah A. ;
Bax, Jeroen J. ;
Derumeaux, Genevieve ;
Grimm, Richard A. ;
Martin, Randy ;
Steinberg, Jonathan S. ;
Sutton, Martin St. John ;
Yu, Cheuk-Man .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (03) :191-213
[8]   Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography [J].
Jenkins, C ;
Bricknell, K ;
Hanekom, L ;
Marwick, TH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (04) :878-886
[9]   Real-time three-dimensional echocardiography - A novel technique to quantify global left ventricular mechanical dyssynchrony [J].
Kapetanakis, S ;
Kearney, MT ;
Siva, A ;
Gall, N ;
Cooklin, M ;
Monaghan, MJ .
CIRCULATION, 2005, 112 (07) :992-1000
[10]   Homogeneity of cardiac contraction despite physiological asynchrony of depolarization: A model study [J].
Kerckhoffs, RCP ;
Bovendeerd, PHM ;
Kotte, JCS ;
Prinzen, FW ;
Smits, K ;
Arts, T .
ANNALS OF BIOMEDICAL ENGINEERING, 2003, 31 (05) :536-547