A patient-specific lumped-parameter model of coronary circulation

被引:55
|
作者
Zheng Duanmu [1 ]
Min Yin [1 ]
Fan, Xueling [1 ]
Yang, Xilan [2 ]
Luo, Xiaoyu [3 ]
机构
[1] Xi An Jiao Tong Univ, Sch Aerosp Engn, State Key Lab Strength & Vibrat Mech Struct, Xian, Shaanxi, Peoples R China
[2] Nanjing Med Univ, Affiliated Hosp 2, Nanjing, Jiangsu, Peoples R China
[3] Univ Glasgow, Sch Math & Stat, Glasgow, Lanark, Scotland
来源
SCIENTIFIC REPORTS | 2018年 / 8卷
关键词
PULSATILE BLOOD-FLOW; CAROTID-ARTERY; NUMERICAL-SIMULATION; FLUID-DYNAMICS; PRESSURE; TREE; WILLIS; CIRCLE; VALIDATION; STENOSIS;
D O I
10.1038/s41598-018-19164-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A new lumped-parameter model for coronary hemodynamics is developed. This model is developed for the whole coronary network based on CT scans of a patient-specific geometry including the right coronary tree, which is absent in many previous mathematical models. The model adopts the structured tree model boundary conditions similar to the work of Olufsen et al., thus avoiding the necessity of invasive perfusion measurements. In addition, we also incorporated the effects of the head loss at the two inlets of the large coronary arteries for the first time. The head loss could explain the phenomenon of a sudden increase of the resistance at the inlet of coronary vessel. The estimated blood pressure and flow rate results from the model agree well with the clinical measurements. The computed impedances also match the experimental perfusion measurement. The effects of coronary arterial stenosis are considered and the fractional flow reserve and relative flow in the coronary vessels for a stenotic vessel computed in this model show good agreement with published experimental data. It is believed that the approach could be readily translated to clinical practice to facilitate real time clinical diagnosis.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A patient-specific lumped-parameter model of coronary circulation
    Zheng Duanmu
    Min Yin
    Xueling Fan
    Xilan Yang
    Xiaoyu Luo
    Scientific Reports, 8
  • [2] A PATIENT-SPECIFIC LUMPED PARAMETER MODEL OF HUMAN PENILE ERECTION
    Pekkan, K.
    Erturk, H.
    Culha, M. G.
    Serefoglu, E. C.
    JOURNAL OF SEXUAL MEDICINE, 2017, 14 (01): : S128 - S128
  • [3] A female-specific cardiovascular lumped-parameter model
    Comunale, Giulia
    Susin, Francesca M.
    Mynard, Jonathan P.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2654 - 2657
  • [4] A LUMPED-PARAMETER MODEL FOR INFILTRATION
    PINGOUD, K
    JOURNAL OF HYDROLOGY, 1982, 57 (1-2) : 175 - 185
  • [5] Patient-specific parameter estimation in single-ventricle lumped circulation models under uncertainty
    Schiavazzi, Daniele E.
    Baretta, Alessia
    Pennati, Giancarlo
    Hsia, Tain-Yen
    Marsden, Alison L.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2017, 33 (03)
  • [6] A PATIENT-SPECIFIC REDUCED-ORDER MODEL FOR CORONARY CIRCULATION
    Itu, Lucian
    Sharma, Puneet
    Mihalef, Viorel
    Kamen, Ali
    Suciu, Constantin
    Comaniciu, Dorin
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 832 - 835
  • [7] Patient-specific cranio-spinal compliance distribution using lumped-parameter model: its relation with ICP over a wide age range
    Ritambhar Burman
    Noam Alperin
    Sang H. Lee
    Brigit Ertl-Wagner
    Fluids and Barriers of the CNS, 15
  • [8] Patient-specific cranio-spinal compliance distribution using lumped-parameter model: its relation with ICP over a wide age range
    Burman, Ritambhar
    Alperin, Noam
    Lee, Sang H.
    Ertl-Wagner, Brigit
    FLUIDS AND BARRIERS OF THE CNS, 2018, 15
  • [9] Inertance Estimation in a Lumped-Parameter Hydraulic Simulator of Human Circulation
    Lanzarone, Ettore
    Ruggeri, Fabrizio
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (06):
  • [10] A cardiac electromechanical model coupled with a lumped-parameter model for closed-loop blood circulation
    Regazzoni, F.
    Salvador, M.
    Africa, P. C.
    Fedele, M.
    Dede, L.
    Quarteroni, A.
    JOURNAL OF COMPUTATIONAL PHYSICS, 2022, 457