Simulation of Natural Gas Dispersion and Explosion in Vented Enclosure using 3D CFD FLACS Software

被引:3
作者
Juwari [1 ]
Handogo, Renanto [1 ]
Cahyono, Teguh [1 ]
Safarudin, Mochamad [1 ]
Anugraha, Rendra Panca [1 ]
Aulia, Fadhilatul [1 ]
Kurniaty, Nuvies Dwi [1 ]
Habibi, Muhamad Reza [1 ]
Kharisma, Muhammad Nuur [1 ]
机构
[1] Sepuluh Nopember Inst Technol ITS, Dept Chem Engn, Fac Ind Technol, Kampus ITS Sukolilo, Surabaya 60111, Indonesia
来源
26TH REGIONAL SYMPOSIUM ON CHEMICAL ENGINEERING (RSCE 2019) | 2020年 / 778卷
关键词
D O I
10.1088/1757-899X/778/1/012144
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Natural gas is used as fuel in industries, power plants, commercial installations, and households. In its application, natural gas leaks can be considered as a major hazard because of its flammable and explosive nature. In addition to fuel, heat and oxygen sources, fires and explosions can occur if the concentration of natural gas in the air is between Low Flammable Limit (LFL) and Upper Flammable Limit (UFL). If the release of natural gas is not ignited, it will immediately form a Vapor Cloud Explosion (VCE) that can cause an explosion if it meets ignition point. Therefore, a research on dispersion patterns in a particular area or space is needed to minimize hazards and to develop safety procedures and regulations. This research aims to determine the external parameters that affect the dispersion and explosion caused by natural gas by using FLACS software from PT. Gexcon Indonesia. This software can display overpressure graphs of time and 3D visuals of simulations. The external parameters consist of vent size (5.4 m2 and 2.7 m2), wind direction, lighter position (center and back), day and night condition, and the presence of a obstacle (with and without obstacle). From the research results by the simulations, it is obtained that the highest overpressure value when there is an obstacle with a vent size of 2.7 m2; wind direction from the north; night condition, and back ignition point is 0.503 bars at 40,835 s which can cause most buildings to collapse and the death rate to increase.
引用
收藏
页数:12
相关论文
共 18 条
[1]   Effect of hydrogen concentration on vented explosion overpressures from lean hydrogen-air deflagrations [J].
Bauwens, C. R. ;
Chao, J. ;
Dorofeev, S. B. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2012, 37 (22) :17599-17605
[2]  
Bauwens C. R., 2008, FM GLOBAL ENG RES, P1
[3]   Effect of Ignition Location, Vent Size, and Obstacles on Vented Explosion Overpressures in Propane-Air Mixtures [J].
Bauwens, C. Regis ;
Chaffee, Jeff ;
Dorofeev, Sergey .
COMBUSTION SCIENCE AND TECHNOLOGY, 2010, 182 (11-12) :1915-1932
[4]  
Crowl D.A., 2002, CHEM PROCESS SAFETY, VSecond
[5]  
ESDM, 2013, KAJ SUBS GAS DENG EN
[6]   Validation of FLACS against experimental data sets from the model evaluation database for LNG vapor dispersion [J].
Hansen, Olav R. ;
Gavelli, Filippo ;
Ichard, Mathieu ;
Davis, Scott G. .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2010, 23 (06) :857-877
[7]  
Kletz T.A., 1987, BEST BUILDING HAS NO
[8]  
Less F.P., 1996, Loss Prevention in the Process Industries, V2nd
[9]  
Nolan D.P., 1996, Handbook of Fire and Explosion Protection Engineering Priciples for Oil, Gas, Chemical and Related Facilities
[10]  
Pasquill F., 1974, ATMOSPHERIC DIFFUSIO