Plug flow cytometry: An automated coupling device for rapid sequential flow cytometric sample analysis

被引:0
作者
Edwards, BS
Kuckuck, F
Sklar, LA [1 ]
机构
[1] Univ New Mexico, Hlth Sci Ctr, Canc Res & Treatment Ctr, Dept Cytometry, Albuquerque, NM 87131 USA
[2] Univ New Mexico, Hlth Sci Ctr, Dept Pathol, Albuquerque, NM 87131 USA
来源
CYTOMETRY | 1999年 / 37卷 / 02期
关键词
flow cytometry; automation; sample handling;
D O I
10.1002/(SICI)1097-0320(19991001)37:2<156::AID-CYTO9>3.0.CO;2-T
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: The tools for high throughput flow cytometry have been limited in part because of the requirement that the samples must flow under pressure. We describe a simple system for sampling repetitively from an open vessel. Methods: Under computer control, the sample is loaded into a sample loop in a reciprocating eight-way valve by the action of a syringe. When the valve position is switched, the plug of sample in the sample loop is transported to the flow cytometer by a pressure-driven fluid Line. By coupling the plug-forming capability to a second multi-port valve, samples can be delivered sequentially from separate vessels. Results: The valve is able to deliver samples at rates ranging up to about 9 samples per minute. Each plug of sample has uniform delivery characteristics with a reproducible coefficient: of variation (CV). Even at the highest sampling rate, carryover between samples is limited. Conclusions: Plug-flow flow cytometry has the potential to automate the delivery of small samples from unpressurized sources at rates compatible with many screening and assay applications. Cytometry 37:156-159, 1999. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:156 / 159
页数:4
相关论文
共 7 条
[1]  
CHANDLER VS, 1998, CYTOMETRY S, V9, P40
[2]  
Fulton RJ, 1997, CLIN CHEM, V43, P1749
[3]   The emergence of flow cytometry for sensitive, real-time measurements of molecular interactions [J].
Nolan, JP ;
Sklar, LA .
NATURE BIOTECHNOLOGY, 1998, 16 (07) :633-638
[4]   A RAPID MIX FLOW CYTOMETER WITH SUBSECOND KINETIC RESOLUTION [J].
NOLAN, JP ;
POSNER, RG ;
MARTIN, JC ;
HABBERSETT, R ;
SKLAR, LA .
CYTOMETRY, 1995, 21 (03) :223-229
[5]  
Seamer LC, 1999, CYTOMETRY, V35, P75, DOI 10.1002/(SICI)1097-0320(19990101)35:1<75::AID-CYTO10>3.0.CO
[6]  
2-Y
[7]   Sample handling for kinetics and molecular assembly in flow cytometry [J].
Sklar, LA ;
Seamer, LC ;
Kuckuck, F ;
Posner, RG ;
Prossnitz, E ;
Edwards, B ;
Nolan, JP .
ADVANCES IN OPTICAL BIOPHYSICS, PROCEEDINGS OF, 1998, 3256 :144-153