One-shot lactate chemiluminescent biosensor

被引:26
作者
Ballesta-Claver, J. [1 ]
Valencia-Miron, M. C. [1 ]
Capitan-Vallvey, L. F. [1 ]
机构
[1] Univ Granada, Fac Sci, Dept Analyt Chem, Solid Phase Spectrometry Res Grp, E-18071 Granada, Spain
关键词
Lactate determination; Biosensor; Chemiluminescence; One-shot biosensor; Yoghurt analysis;
D O I
10.1016/j.aca.2008.09.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new chemiluminescence-based one-shot biosensor for lactate is described. The lactate recognition system is based on lactate oxidase (LOx) and the transduction system consists of luminol, peroxidase from Arthromyces ramosus (ARP) and metallic aluminum, all immobilized in a polyion complex membrane. The measurement of the chemiluminescence in a luminometer when 1 mL of sample is injected into a conventional cell containing the disposable sensing membrane makes it possible to determine lactate. The compositions of the membrane and reaction conditions have been optimized to obtain adequate sensitivity. The one-shot biosensor responds to lactate rapidly, with the typical CL acquisition time being 2 min, with a linearized logarithmic dependence whose dynamic range was from 5 x 10(-5) to 4 x 10(-3) with a detection limit of 9.2 x 10(-6) M and a sensor-to-sensor reproducibility (relative standard deviation, R.S.D.) of 5.5% at the medium level of the range. The performance of the chemiluminescent one-shot biosensor was tested for the analysis of lactate in yoghurt, validating the results against an enzymatic reference procedure. The proposed method is quick, inexpensive and sensitive and uses conventional CL instrumentation. (C) 2008 Elsevier B.V All rights reserved.
引用
收藏
页码:136 / 144
页数:9
相关论文
共 55 条
  • [1] Chemiluminescence-based (bio) sensors - An overview
    Aboul-Enein, HY
    Stefan, RI
    van Staden, JF
    [J]. CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1999, 29 (04) : 323 - 331
  • [2] AKHAVANTAFTI H, 1998, Patent No. 5843666
  • [3] [Anonymous], 2002, ESTADISTICA QUIMIOME
  • [4] Screen-printed biosensors for the control of wine quality based on lactate and acetaldehyde determination
    Avramescu, A
    Noguer, T
    Avramescu, M
    Marty, JL
    [J]. ANALYTICA CHIMICA ACTA, 2002, 458 (01) : 203 - 213
  • [5] BELLY RT, 1999, Patent No. 5958339
  • [6] CHARACTERIZATION AND APPLICATION OF PRECISE AND ROBUST FLOW-INJECTION ANALYZERS FOR ONLINE MEASUREMENT DURING FERMENTATIONS
    BENTHIN, S
    NIELSEN, J
    VILLADSEN, J
    [J]. ANALYTICA CHIMICA ACTA, 1991, 247 (01) : 45 - 50
  • [7] ENHANCEMENT OF THE RESPONSE OF A LACTATE OXIDASE/PEROXIDASE-BASED FIBEROPTIC SENSOR BY COMPARTMENTALIZATION OF THE ENZYME LAYER
    BERGER, A
    BLUM, LJ
    [J]. ENZYME AND MICROBIAL TECHNOLOGY, 1994, 16 (11) : 979 - 984
  • [8] MULTICOMPONENT ORGANIZED BIOACTIVE LAYERS FOR FIBEROPTIC LUMINESCENT SENSORS
    BLUM, LJ
    GAUTIER, SM
    BERGER, A
    MICHEL, PE
    COULET, PR
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1995, 29 (1-3) : 1 - 9
  • [9] BRAIG JR, 2006, Patent No. 2006127724
  • [10] CAPITANVALLVEY LF, 2005, ENCY SENSORS