In-vitro characteristics of cemented titanium femoral stems with a smooth surface finish

被引:6
|
作者
Akiyama, Haruhiko [1 ]
Yamamoto, Koji [1 ]
Kaneuji, Ayumi [2 ]
Matsumoto, Tadami [2 ]
Nakamura, Takashi [1 ]
机构
[1] Kyoto Univ, Dept Orthopaed, Sakyo Ku, Kyoto 6068507, Japan
[2] Kanazawa Med Univ, Dept Orthopaed Surg, Kahokugun, Ishikawa, Japan
关键词
TOTAL HIP REPLACEMENTS; LONG-TERM SURVIVAL; FOLLOW-UP; COMPONENT; ARTHROPLASTY; CHARNLEY; DESIGN; STRESSES; FEMUR; WEAR;
D O I
10.1007/s00776-012-0298-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In cemented total hip arthroplasty (THA), a polished tapered femoral stem with a design based on the taper-slip concept enables extremely reliable and durable fixation. In contrast, cemented femoral stems made from titanium alloys are not favored because of reports describing insufficient clinical outcomes. However, we have reported excellent clinical and radiological outcomes for cemented titanium stems made using the composite-beam concept. This study examines the characteristics of cemented titanium femoral stems with a smooth surface. The bonding strength between titanium alloys with different surface finishes and bone cement was evaluated by use of push-out and detachment tests. Torsional stability tests were performed to evaluate the initiation and propagation of disruption of the fixation of cemented stems at the cement-implant interface. The wear resistance was investigated by use of wear-friction tests performed using a multidirectional pin-on-disc machine. The bone strain loaded on to the femoral cortex was measured by use of an implanted Sawbone and analyzed by use of the finite element method. The push-out and detachment tests revealed increasing cement adhesion strength with increasing degree of roughness of the metal surface. The torsional stability tests indicated that a load > 1,000 N led to progressive debonding between the cement and the implant with a smooth surface finish. Interestingly, wear-friction tests revealed the wear rate for polished titanium surfaces was clearly higher than for smooth surfaces. In addition, the greater elasticity of titanium stems compared with cobalt-chromium stems transmitted the external load to the proximal side of the femur more effectively. The smooth surface finish of the stems is an important factor for the satisfactory clinical and radiological outcomes of cemented titanium femoral stems. The greater elasticity of a titanium stem effectively transmits the external load to the medial side of the femur.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 50 条
  • [31] Effect of titanium surface characteristics on chondrocytes and osteoblasts in vitro - Discussion
    Chehroudi, B
    Bailer, RE
    CELLS AND MATERIALS, 1995, 5 (04): : 334 - 335
  • [32] A comparative clinical outcome evaluation of smooth (10–13 year results) versus rough surface finish (5–8 year results) in an otherwise identically designed cemented titanium alloy stem
    F. Hinrichs
    M. Kuhl
    U. Boudriot
    P. Griss
    Archives of Orthopaedic and Trauma Surgery, 2003, 123 : 268 - 272
  • [33] Wettability and in-vitro study of titanium surface profiling prepared by electrolytic plasma processing
    Boonrawd, Wisanu
    Awad, Kamal R.
    Varanasi, Venu
    Meletis, Efstathios, I
    SURFACE & COATINGS TECHNOLOGY, 2021, 414
  • [34] In-Vitro Phenotypic Response of Human Osteoblasts to Different Degrees of Titanium Surface Roughness
    Osman, Muataz A.
    Alamoush, Rasha A.
    Kushnerev, Evgeny
    Seymour, Kevin G.
    Shawcross, Susan
    Yates, Julian M.
    DENTISTRY JOURNAL, 2022, 10 (08)
  • [35] Surface characteristics and in vitro biocompatibility of a manganese-containing titanium oxide surface
    Park, Jin-Woo
    Kim, Youn-Jeong
    Jang, Je-Hee
    APPLIED SURFACE SCIENCE, 2011, 258 (02) : 977 - 985
  • [36] In vitro investigation of fluid flow around well fixed simulated femoral components of differing geometry and surface finish
    Crawford, R
    Ling, R
    Murray, D
    SIROT 99, 1999, : 403 - 408
  • [37] In-vitro evaluation of the material characteristics of stainless steel and beta-titanium orthodontic wires
    Verstrynge, Astrid
    Van Humbeeck, Jan
    Willems, Guy
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2006, 130 (04) : 460 - 470
  • [38] Bioactivity and Surface Characteristics of Titanium Implants Following Various Surface Treatments: An In Vitro Study
    Kumar, Aswini K.
    Bhatt, Vinaya
    Balakrishnan, Manilal
    Hashem, Mohamed
    Vellappally, Sajith
    Al Kheraif, Abdul Aziz A.
    Halawany, Hassan Suliman
    Abraham, Nimmi Biju
    Jacob, Vimal
    Anil, Sukumaran
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (05) : E183 - E188
  • [39] Effects of multiple sterilization on surface characteristics and in vitro biologic responses to titanium
    Vezeau, PJ
    Koorbusch, GF
    Draughn, RA
    Keller, JC
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (06) : 738 - 746
  • [40] Effectiveness of strontium/silver-based titanium surface coatings in improving antibacterial and osteogenic implant characteristics: a systematic review of in-vitro studies
    Kheirmand-Parizi, Marjan
    Doll-Nikutta, Katharina
    Gaikwad, Amit
    Denis, Hannah
    Stiesch, Meike
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12