In-vitro characteristics of cemented titanium femoral stems with a smooth surface finish

被引:6
|
作者
Akiyama, Haruhiko [1 ]
Yamamoto, Koji [1 ]
Kaneuji, Ayumi [2 ]
Matsumoto, Tadami [2 ]
Nakamura, Takashi [1 ]
机构
[1] Kyoto Univ, Dept Orthopaed, Sakyo Ku, Kyoto 6068507, Japan
[2] Kanazawa Med Univ, Dept Orthopaed Surg, Kahokugun, Ishikawa, Japan
关键词
TOTAL HIP REPLACEMENTS; LONG-TERM SURVIVAL; FOLLOW-UP; COMPONENT; ARTHROPLASTY; CHARNLEY; DESIGN; STRESSES; FEMUR; WEAR;
D O I
10.1007/s00776-012-0298-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In cemented total hip arthroplasty (THA), a polished tapered femoral stem with a design based on the taper-slip concept enables extremely reliable and durable fixation. In contrast, cemented femoral stems made from titanium alloys are not favored because of reports describing insufficient clinical outcomes. However, we have reported excellent clinical and radiological outcomes for cemented titanium stems made using the composite-beam concept. This study examines the characteristics of cemented titanium femoral stems with a smooth surface. The bonding strength between titanium alloys with different surface finishes and bone cement was evaluated by use of push-out and detachment tests. Torsional stability tests were performed to evaluate the initiation and propagation of disruption of the fixation of cemented stems at the cement-implant interface. The wear resistance was investigated by use of wear-friction tests performed using a multidirectional pin-on-disc machine. The bone strain loaded on to the femoral cortex was measured by use of an implanted Sawbone and analyzed by use of the finite element method. The push-out and detachment tests revealed increasing cement adhesion strength with increasing degree of roughness of the metal surface. The torsional stability tests indicated that a load > 1,000 N led to progressive debonding between the cement and the implant with a smooth surface finish. Interestingly, wear-friction tests revealed the wear rate for polished titanium surfaces was clearly higher than for smooth surfaces. In addition, the greater elasticity of titanium stems compared with cobalt-chromium stems transmitted the external load to the proximal side of the femur more effectively. The smooth surface finish of the stems is an important factor for the satisfactory clinical and radiological outcomes of cemented titanium femoral stems. The greater elasticity of a titanium stem effectively transmits the external load to the medial side of the femur.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 50 条
  • [1] Corrosion of cemented titanium femoral stems
    Thomas, SR
    Shukla, D
    Latham, PD
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (07): : 974 - 978
  • [2] Initial stability of cemented femoral stems as a function of surface finish, collar, and stem size
    Ebramzadeh, E
    Sangiorgio, SN
    Longjohn, DB
    Buhari, CE
    Dorr, LD
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (01): : 106 - 115
  • [3] Cemented femoral component surface finish mechanics
    Crowninshield, RD
    Jennings, JD
    Laurent, ML
    Maloney, WJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (355) : 90 - 102
  • [4] The effect of a collar and surface finish on cemented femoral stems: a prospective randomised trial of four stem designs
    Jonathan Hutt
    Alexandra Hazlerigg
    Ansari Aneel
    Geoffrey Epie
    Husam Dabis
    Roy Twyman
    Andrew Cobb
    International Orthopaedics, 2014, 38 : 1131 - 1137
  • [5] Surface finish mechanics explain different clinical survivorship of cemented femoral stems for total hip arthroplasty
    Beksac, Burak
    Taveras, Nicole A.
    Valle, Alejandro Gonzalez Della
    Salvati, Eduardo A.
    Journal of Long-Term Effects of Medical Implants, 2006, 16 (06) : 407 - 422
  • [6] The effect of a collar and surface finish on cemented femoral stems: a prospective randomised trial of four stem designs
    Hutt, Jonathan
    Hazlerigg, Alexandra
    Aneel, Ansari
    Epie, Geoffrey
    Dabis, Husam
    Twyman, Roy
    Cobb, Andrew
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (06) : 1131 - 1137
  • [7] In vitro stability of cemented and cementless femoral stems with compaction
    Chareancholvanich, K
    Bourgeault, CA
    Schmidt, AH
    Gustilo, RB
    Lew, WD
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (394) : 290 - 302
  • [8] The effect of surface finish and of vertical ribs on the stability of a cemented femoral stem: An in vitro stair climbing test
    Jamali, AA
    Lozynsky, AJ
    Harris, WH
    JOURNAL OF ARTHROPLASTY, 2006, 21 (01): : 122 - 128
  • [9] The development of surface topography during wear of matt finish femoral stems
    Brown, LT
    Blunt, L
    Howell, J
    1ST INTERNATIONAL CONFERENCE ON TRIBOLOGY IN ENVIRONMENTAL DESIGN 2000: THE CHARACTERISTICS OF INTERACTING SURFACES - A KEY FACTOR IN SUSTAINABLE AND ECONOMIC PRODUCTS, 2000, : 39 - 48
  • [10] A rough surface finish adversely affects the survivorship of a cemented femoral stem
    Della Valle, AG
    Zoppi, A
    Peterson, MGE
    Salvati, EA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) : 158 - 163