Multi-criteria assessment and optimization study on 5 kW PEMFC based residential CCHP system

被引:113
作者
Chen, Xi [1 ,2 ]
Zhou, Haowei [1 ,2 ]
Li, Wenbin [1 ,4 ]
Yu, Zhengkun [1 ,2 ]
Gong, Guangcai [3 ]
Yan, Yongtao [1 ]
Luo, Liang [1 ,2 ]
Wan, Zhongmin [1 ,2 ]
Ding, Yuejiao [1 ]
机构
[1] Hunan Inst Sci & Technol, Coll Mech Engn, Yueyang 414006, Peoples R China
[2] Hunan Inst Sci & Technol, Inst New Energy, Yueyang 414006, Peoples R China
[3] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
[4] Cent S Univ, Sch Informat Sci & Engn, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
PEMFC; CCHP; Multi-criteria assessment; Multi-optimization; NSGA-II; MEMBRANE FUEL-CELL; MICRO-COMBINED HEAT; DEAD-ENDED ANODE; MULTIOBJECTIVE OPTIMIZATION; RENEWABLE-ENERGY; CARBON CORROSION; POWER-SYSTEM; PERFORMANCE; DEGRADATION; HYDROGEN;
D O I
10.1016/j.enconman.2018.01.050
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a multi-criteria assessment (including thermodynamics, economics and environment) study on 5 kW PEMFC based residential combined cooling, heating and power system (CCHP). The system is mainly composed of a 5 kW PEMFC stack, a heat recovery system, a small absorption chiller and auxiliary component (including gas compressor and humidifier), which can provide electric power, space heating/cooling and hot water for apartment simultaneously. The thermodynamic model of the CCHP system is partially validated. The system performances, including energy and exergy efficiencies, annual cost and pollutant emission reduction, are evaluated in a parametric analysis method. Moreover, aiming at improving the evaluation indexes, the system is optimized using evolution algorithm, and three dimensional (3D) Pareto solutions and optimal operating parameter set are obtained. The results indicate that low operating temperature, high relative humidity and pressure of inlet gases are helpful for improving system exergy efficiency and GHG emission reduction. The optimized system exergy efficiency, annual cost and GHG emission reduction at Final Optimal Point (FOP) are 39.9%, 29337.3$ and 1.82 x 10(7) g, respectively. Comparing with un-optimized system, the system working at optimal parameters shows better performances in both exergy efficiency and GHG emission reduction besides a sacrifice in economic cost.
引用
收藏
页码:384 / 395
页数:12
相关论文
共 39 条
  • [1] Thermodynamic modeling and multi-objective evolutionary-based optimization of a new multigeneration energy system
    Ahmadi, Pouria
    Dincer, Ibrahim
    Rosen, Marc A.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2013, 76 : 282 - 300
  • [2] Review of tri-generation technologies: Design evaluation, optimization, decision-making, and selection approach
    Al Moussawi, Houssein
    Fardoun, Farouk
    Louahlia-Gualous, Hasna
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 120 : 157 - 196
  • [3] Assessment of the environmental benefits of transport and stationary fuel cells
    Bauen, A
    Hart, D
    [J]. JOURNAL OF POWER SOURCES, 2000, 86 (1-2) : 482 - 494
  • [4] Multi-criteria optimization of a micro solar-geothermal CCHP system applying water/CuO nanofluid based on exergy, exergoeconomic and exergoenvironmental concepts
    Boyaghchi, Fateme Ahmadi
    Chavoshi, Mansoure
    [J]. APPLIED THERMAL ENGINEERING, 2017, 112 : 660 - 675
  • [5] A review on the energy production, consumption, and prospect of renewable energy in China
    Chang, J
    Leung, DYC
    Wu, CZ
    Yuan, ZH
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2003, 7 (05) : 453 - 468
  • [6] Carbon corrosion and performance degradation mechanism in a proton exchange membrane fuel cell with dead-ended anode and cathode
    Chen, Ben
    Wang, Jun
    Yang, Tianqi
    Cai, Yonghua
    Zhang, Caizhi
    Chan, Siew Hwa
    Yu, Yi
    Tu, Zhengkai
    [J]. ENERGY, 2016, 106 : 54 - 62
  • [7] Operation characteristics and carbon corrosion of PEMFC (Proton exchange membrane fuel cell) with dead-ended anode for high hydrogen utilization
    Chen, Ben
    Ke, Wandi
    Luo, Maji
    Wang, Jun
    Tu, Zhengkai
    Pan, Mu
    Zhang, Haining
    Liu, Xiaowei
    Liu, Wei
    [J]. ENERGY, 2015, 91 : 799 - 806
  • [8] Parametric analysis and optimization of PEMFC system for maximum power and efficiency using MOEA/D
    Chen, Xi
    Li, Wenbin
    Gong, Guangcai
    Wan, Zhongmin
    Tu, Zhengkai
    [J]. APPLIED THERMAL ENGINEERING, 2017, 121 : 400 - 409
  • [9] Performance study of a dual power source residential CCHP system based on PEMFC and PTSC
    Chen, Xi
    Gong, Guangcai
    Wan, Zhongmin
    Zhang, Caizhi
    Tu, Zhengkai
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 119 : 163 - 176
  • [10] Performance analysis of 5 kW PEMFC-based residential micro-CCHP with absorption chiller
    Chen, Xi
    Gong, Guangcai
    Wan, Zhongmin
    Luo, Liang
    Wan, Junhua
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (33) : 10647 - 10657