Improvements on metallic ion beams at GANIL with the large-capacity oven

被引:8
作者
Leherissier, P. [1 ]
Lemagnen, F. [1 ]
Canet, C. [1 ]
Barue, C. [1 ]
Dupuis, M. [1 ]
Flambard, J. L. [1 ]
Dubois, M. [1 ]
Gaubert, G. [1 ]
Jardin, P. [1 ]
Lecesne, N. [1 ]
Leroy, R. [1 ]
Pacquet, J. Y. [1 ]
机构
[1] GANIL, F-14076 Caen 5, France
关键词
D O I
10.1063/1.2164888
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the last two years the development of the large-capacity oven was continued. First tests on-line with calcium, lead, tin and magnesium beams were achieved. We successfully produced 30 mu A of Ca9+, 13 mu A of Pb23+, 8 mu A of Sr21+, and 50 mu A of Mg7+. Some deformation of the filament appeared when working at high temperature. Several configurations of the filament and the use of an alternate power supply have been tested to solve this problem. The beam's intensities and the ionization efficiencies were improved in comparison with the standard microoven performances. The results of magnesium beam, 110 mu A of Mg5+ obtained with the "MIVOC" method are compared with those using the oven technique. (c) 2006 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 5 条
[1]   Production of metallic ions with an ECRIS at GANIL [J].
Bex, L ;
Dupuis, M ;
Flambard, JL ;
Leherissier, P ;
Rataud, JP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02) :792-794
[2]  
EFREMOV A, 1998, UNPUB P 15 INT C CYC, P145
[3]   Status report on ECR ion source operation at GANIL [J].
Lehérissier, P ;
Barué, C ;
Canet, C ;
Dubois, M ;
Dupuis, M ;
Flambard, JL ;
Gaubert, G ;
Jardin, P ;
Lecesne, N ;
Lemagnen, F ;
Leroy, R ;
Pacquet, JY ;
Pellemoine-Landre, F .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05) :1488-1491
[4]   High intensity metallic ion beams from an ECR ion source at GANIL [J].
Lehérissier, P ;
Barué, C ;
Canet, C ;
Dupuis, M ;
Flambard, JL ;
Gaubert, G ;
Gibouin, S ;
Huguet, Y ;
Jaffres, PA ;
Jardin, P ;
Lecesne, N ;
Lemagnen, F ;
Leroy, R ;
Pacquet, JY ;
Pellemoine-Landré, F ;
Rataud, JP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02) :558-560
[5]  
LEHERISSIER P, 2003, GANIL TECHNICAL REPO