Marginal fit of 14-unit zirconia fixed dental prosthesis retainers

被引:47
|
作者
Beuer, F. [2 ]
Neumeier, P. [2 ]
Naumann, M. [1 ]
机构
[1] Univ Leipzig, Dept Prosthodont, Leipzig, Germany
[2] Univ Munich, Dept Prosthodont, Munich, Germany
关键词
fixed dental prosthesis; full-arch restoration; single crown; marginal fit; computer-aided design; computer-aided manufacturing; zirconia; pre-sintered zirconia; FUSED-TO-METAL; PARTIAL DENTURES; CERAMIC CROWN; INTERNAL FIT; IN-VITRO; FRAMEWORKS; COPINGS; RELIABILITY; STRENGTH; RESTORATIONS;
D O I
10.1111/j.1365-2842.2008.01908.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The marginal fit of 14-unit fixed dental prosthesis retainers and single-crown copings fabricated by the same computer-aided design (CAD)/computer-aided manufacturing (CAM) system were evaluated in vitro hypothesizing that the marginal opening might be independent of the type of restoration. Eight ivorine maxillary teeth (FDI locations 27, 25, 23, 21, 11, 13, 15 and 17) were prepared to accommodate a 14-unit prosthesis. Ten fixed dental prosthesis retainers and 40 single-crown-copings were fabricated using Zeno CAD/CAM on 20 master dies. Four cross-sections were made from each tooth and the marginal gap dimensions were measured. One-way anova was used to test the difference between the experimental groups and two-way anova and a post hoc test (Student-Newman-Keuls) were carried out to determine the influence of the location of the abutment tooth and the measurement location within the abutment tooth in the experimental groups (P < 0.05). Mean marginal gap dimensions and standard deviations for fixed dental prosthesis retainers and single-crown copings were 25 +/- 29 and 13 +/- 12 mu m, respectively. The type of restoration showed a significant influence (P < 0.001) on the marginal gap. The location of the abutment tooth (P < 0.001) and the measurement location (P < 0.001) exhibited significant influence on marginal gaps of fixed dental prosthesis retainers while no influence on single-crown copings could be detected. The highest marginal gaps were found at the palatal surface of the incisor and canine of the 14-unit fixed dental prosthesis retainers. Fourteen-unit fixed dental prosthesis showed significantly higher marginal openings than single crowns fabricated under the same conditions. However, both restorations showed clinically acceptable marginal openings.
引用
收藏
页码:142 / 149
页数:8
相关论文
共 50 条
  • [1] Marginal and internal fits of fixed dental prostheses zirconia retainers
    Beuer, Florian
    Aggstaller, Hans
    Edelhoff, Daniel
    Gernet, Wolfgang
    Sorensen, John
    DENTAL MATERIALS, 2009, 25 (01) : 94 - 102
  • [2] Precision of fit: zirconia three-unit fixed dental prostheses
    Beuer, Florian
    Naumann, Michael
    Gernet, Wolfgang
    Sorensen, John A.
    CLINICAL ORAL INVESTIGATIONS, 2009, 13 (03) : 343 - 349
  • [3] Evaluation of Marginal and Internal Fit of Presintered Co-Cr and Zirconia Three-Unit Fixed Dental Prosthesis Compared to Cast Co-Cr
    Daou, Elie E.
    Baba, Nadim Z.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (09): : 792 - 799
  • [4] Computer-aided Fabrication of a Zirconia 14-unit Removable Dental Prosthesis: A Technical Report
    Groesser, J.
    Sachs, C.
    Stadelmann, M.
    Schweiger, J.
    Gueth, J. -F.
    Beuer, F.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2014, 17 (04) : 307 - 316
  • [5] The effect of pre-ceramic soldering on marginal and internal fit of 4-unit zirconia frameworks and monolithic zirconia fixed dental prostheses
    Irem, Diler Ozkan
    Alpkilic, Dilara Seyma
    Deger, Sabire Isler
    ODONTOLOGY, 2024, 112 (01) : 169 - 176
  • [6] Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses
    Kohorst, P.
    Brinkmann, H.
    Dittmer, M. P.
    Borchers, L.
    Stiesch, M.
    JOURNAL OF ORAL REHABILITATION, 2010, 37 (04) : 283 - 291
  • [7] Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials
    Schoenberger, Joana
    Erdelt, Kurt-Juergen
    Baeumer, Daniel
    Beuer, Florian
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (08) : 2629 - 2635
  • [8] Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems
    Song, Tae-Jin
    Kwon, Taek-Ka
    Yang, Jae-Ho
    Han, Jung-Suk
    Lee, Jai-Bong
    Kim, Sung-Hun
    Yeo, In-Sung
    JOURNAL OF ADVANCED PROSTHODONTICS, 2013, 5 (03) : 219 - 225
  • [9] Marginal and internal fit of curved anterior CAD/CAM-milled zirconia fixed dental prostheses: An in-vitro study
    Buechi, Dominik L.
    Ebler, Sabine
    Haemmerle, Christoph H. F.
    Sailer, Irena
    QUINTESSENCE INTERNATIONAL, 2014, 45 (10): : 837 - 846
  • [10] The effect of pre-ceramic soldering on marginal and internal fit of 4-unit zirconia frameworks and monolithic zirconia fixed dental prostheses
    Diler Ozkan Irem
    Dilara Seyma Alpkilic
    Sabire Isler Deger
    Odontology, 2024, 112 : 169 - 176