Trace determination of perchlorate in drinking water by capillary zone electrophoresis with isotachophoresis sample cleanup and conductivity detection

被引:3
|
作者
Zabensky, Branislav [1 ]
Bodor, Robert [1 ]
Makata, David [1 ]
Szucs, Roman [1 ]
Masar, Marian [1 ]
机构
[1] Comenius Univ, Fac Nat Sci, Dept Analyt Chem, Mlynska Dolina CH2,Ilkovicova 6, Bratislava 84215, Slovakia
关键词
capillary zone electrophoresis; column coupling technology; isotachophoresis; perchlorate; polyvinylpyrrolidone; ION CHROMATOGRAPHY; ELECTROKINETIC INJECTION; POSTBLAST RESIDUES; MASS-SPECTROMETRY; INORGANIC ANIONS; IDENTIFICATION; CONTAMINATION; SEPARATIONS; ACIDS; CHIP;
D O I
10.1002/jssc.202200188
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical test procedure for the direct determination of trace levels of perchlorate in drinking water by isotachophoresis combined with capillary zone electrophoresis was developed. A capillary electrophoresis analyzer with column coupling technology, capable of combining capillaries with different internal diameters, was employed in combination with conductivity detection. This combination of the capillary electrophoresis techniques facilitated preconcentration of the trace analytes and elimination of potentially interfering macro-components. To eliminate the influence of weak and moderately strong acids on the migration of perchlorate, acidic leading electrolyte (pH 3.2) in the isotachophoresis step and acidic background electrolyte (pH 3.9) in the zone electrophoresis step were chosen. The addition of polyvinylpyrrolidone into the electrolytes enhanced the resolution of perchlorate from other anions, especially remaining anionic macro-components. The developed method is characterized by good repeatability of migration time (relative standard deviation less than 0.2%) as well as peak area (relative standard deviation less than 5.9%), linearity (R = 0.9996), recoveries (100%-112%), and sample throughput (90 samples/24 h). The limit of quantitation for perchlorate in drinking water was achieved at 12.5 nmol/L (1.25 mu g/L). This approach is more sensitive and more robust than transient isotachophoresis and offers advantages over some more established analytical techniques such as ion chromatography.
引用
收藏
页码:3339 / 3347
页数:10
相关论文
共 50 条
  • [41] Capillary zone electrophoresis of inorganic anions with conductivity detection
    Kaniansky, D
    Zelenska, V
    Baluchova, D
    ELECTROPHORESIS, 1996, 17 (12) : 1890 - 1897
  • [42] Conductivity detection in capillary zone electrophoresis: Inspection by PeakMaster
    Jaros, M
    Soga, T
    van de Goor, T
    Gas, B
    ELECTROPHORESIS, 2005, 26 (10) : 1948 - 1953
  • [43] Determination of fumaric acid in apple juice by on-line coupled capillary isotachophoresis-capillary zone electrophoresis with UV detection
    Kvasnicka, F
    Voldrich, M
    JOURNAL OF CHROMATOGRAPHY A, 2000, 891 (01) : 175 - 181
  • [44] Determination of anionic trace impurities in glycerol by capillary isotachophoresis with enlarged sample load
    Meissner, T
    Eisenbeiss, F
    Jastorff, B
    JOURNAL OF CHROMATOGRAPHY A, 1998, 810 (1-2) : 201 - 208
  • [45] Optimization of a capillary zone electrophoresis-contactless conductivity detection method for the determination of nisin
    Drevinskas, Tomas
    Stankevicius, Mantas
    Bimbiraite-Surviliene, Kristina
    Naujokaityte, Gintare
    Kaskoniene, Vilma
    Kondrotiene, Kristina
    Serniene, Loreta
    Kornysova, Olga
    Malakauskas, Mindaugas
    Maruska, Audrius
    ELECTROPHORESIS, 2018, 39 (19) : 2425 - 2430
  • [46] Prediction of zone patterns in capillary zone electrophoresis with conductivity detection - Concept of the zone conductivity diagram
    Gebauer, P
    Caslavska, J
    Thormann, W
    Bocek, P
    JOURNAL OF CHROMATOGRAPHY A, 1997, 772 (1-2) : 63 - 71
  • [47] On-line capillary isotachophoresis-capillary zone electrophoresis analysis of bromate in drinking waters in an automated analyzer with coupled columns and photometric detection
    Marak, Jozef
    Stanova, Andrea
    Vavakova, Veronika
    Hrenakova, Martina
    Kaniansky, Dusan
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1267 : 252 - 258
  • [48] Trace determination of tetracyclines in water samples by capillary zone electrophoresis combining off-line and on-line sample preconcentration
    Moreno-Gonzalez, David
    Lupion-Enriquez, Isabel
    Garcia-Campana, Ana M.
    ELECTROPHORESIS, 2016, 37 (09) : 1212 - 1219
  • [49] Determination of purity degree and counter-ion content in lecirelin by capillary zone electrophoresis and capillary isotachophoresis
    Sazelova, Petra
    Kasicka, Vaclav
    Solinova, Veronika
    Koval, Dusan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 841 (1-2): : 145 - 151
  • [50] Determination of effective charges and ionic mobilities of polycationic antimicrobial peptides by capillary isotachophoresis and capillary zone electrophoresis
    Tumova, Tereza
    Monincova, Lenka
    Nesuta, Ondrej
    Cerovsky, Vaclav
    Kasicka, Vaclav
    ELECTROPHORESIS, 2017, 38 (16) : 2018 - 2024