Trace determination of perchlorate in drinking water by capillary zone electrophoresis with isotachophoresis sample cleanup and conductivity detection

被引:3
作者
Zabensky, Branislav [1 ]
Bodor, Robert [1 ]
Makata, David [1 ]
Szucs, Roman [1 ]
Masar, Marian [1 ]
机构
[1] Comenius Univ, Fac Nat Sci, Dept Analyt Chem, Mlynska Dolina CH2,Ilkovicova 6, Bratislava 84215, Slovakia
关键词
capillary zone electrophoresis; column coupling technology; isotachophoresis; perchlorate; polyvinylpyrrolidone; ION CHROMATOGRAPHY; ELECTROKINETIC INJECTION; POSTBLAST RESIDUES; MASS-SPECTROMETRY; INORGANIC ANIONS; IDENTIFICATION; CONTAMINATION; SEPARATIONS; ACIDS; CHIP;
D O I
10.1002/jssc.202200188
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical test procedure for the direct determination of trace levels of perchlorate in drinking water by isotachophoresis combined with capillary zone electrophoresis was developed. A capillary electrophoresis analyzer with column coupling technology, capable of combining capillaries with different internal diameters, was employed in combination with conductivity detection. This combination of the capillary electrophoresis techniques facilitated preconcentration of the trace analytes and elimination of potentially interfering macro-components. To eliminate the influence of weak and moderately strong acids on the migration of perchlorate, acidic leading electrolyte (pH 3.2) in the isotachophoresis step and acidic background electrolyte (pH 3.9) in the zone electrophoresis step were chosen. The addition of polyvinylpyrrolidone into the electrolytes enhanced the resolution of perchlorate from other anions, especially remaining anionic macro-components. The developed method is characterized by good repeatability of migration time (relative standard deviation less than 0.2%) as well as peak area (relative standard deviation less than 5.9%), linearity (R = 0.9996), recoveries (100%-112%), and sample throughput (90 samples/24 h). The limit of quantitation for perchlorate in drinking water was achieved at 12.5 nmol/L (1.25 mu g/L). This approach is more sensitive and more robust than transient isotachophoresis and offers advantages over some more established analytical techniques such as ion chromatography.
引用
收藏
页码:3339 / 3347
页数:10
相关论文
共 57 条
  • [31] Trace determination of perchlorate using electromembrane extraction and capillary electrophoresis with capacitively coupled contactless conductivity detection
    Kiplagat, Isaac K.
    Thi Kieu Oanh Doan
    Kuban, Pavel
    Bocek, Petr
    [J]. ELECTROPHORESIS, 2011, 32 (21) : 3008 - 3015
  • [32] Background conductivity independent counter flow preconcentration method for capillary electrophoresis
    Koenka, Israel Joel
    Hauser, Peter C.
    [J]. ELECTROPHORESIS, 2017, 38 (21) : 2721 - 2724
  • [33] Electrokinetic injection across supported liquid membranes: New sample pretreatment technique for online coupling to capillary electrophoresis. Direct analysis of perchlorate in biological samples
    Kuban, Pavel
    Kiplagat, Isaac K.
    Bocek, Petr
    [J]. ELECTROPHORESIS, 2012, 33 (17) : 2695 - 2702
  • [34] Perchlorate, iodine and the thyroid
    Leung, Angela M.
    Pearce, Elizabeth N.
    Braverman, Lewis E.
    [J]. BEST PRACTICE & RESEARCH CLINICAL ENDOCRINOLOGY & METABOLISM, 2010, 24 (01) : 133 - 141
  • [35] Matrix diversion methods for improved analysis of perchlorate by suppressed ion chromatography and conductivity detection
    Lin, Rong
    De Borba, Brian
    Srinivasan, Kannan
    Woodruff, Andy
    Pohl, Chris
    [J]. ANALYTICA CHIMICA ACTA, 2006, 567 (01) : 135 - 142
  • [36] Determination of ammonium in wastewaters by capillary electrophoresis on a column-coupling chip with conductivity detection
    Luc, Milan
    Kruk, Pavol
    Masar, Marian
    [J]. JOURNAL OF SEPARATION SCIENCE, 2011, 34 (13) : 1561 - 1567
  • [37] Review of perchlorate occurrence in large public drinking water systems in the United States of America
    Luis, Steven J.
    Miesner, Elizabeth A.
    Enslin, Clarissa L.
    Heidecorn, Keith
    [J]. WATER SUPPLY, 2019, 19 (03) : 681 - 694
  • [38] INFLUENCE OF POLY(VINYLPYRROLIDONE) ON ISOTACHOPHORETIC SEPARATIONS OF INORGANIC ANIONS IN AQUEOUS-ELECTROLYTE SYSTEMS
    MADAJOVA, V
    TURCELOVA, E
    KANIANSKY, D
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 589 (1-2): : 329 - 332
  • [39] Competitive Inhibition of Thyroidal Uptake of Dietary Iodide by Perchlorate Does Not Describe Perturbations in Rat Serum Total T4 and TSH
    McLanahan, Eva D.
    Andersen, Melvin E.
    Campbell, Jerry L., Jr.
    Fisher, Jeffrey W.
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2009, 117 (05) : 731 - 738
  • [40] POTENTIOMETRIC DETECTION OF ANIONS SEPARATED BY CAPILLARY ELECTROPHORESIS USING AN ION-SELECTIVE MICROELECTRODE
    NANN, A
    PRETSCH, E
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 676 (02) : 437 - 442