Trace determination of perchlorate in drinking water by capillary zone electrophoresis with isotachophoresis sample cleanup and conductivity detection

被引:3
|
作者
Zabensky, Branislav [1 ]
Bodor, Robert [1 ]
Makata, David [1 ]
Szucs, Roman [1 ]
Masar, Marian [1 ]
机构
[1] Comenius Univ, Fac Nat Sci, Dept Analyt Chem, Mlynska Dolina CH2,Ilkovicova 6, Bratislava 84215, Slovakia
关键词
capillary zone electrophoresis; column coupling technology; isotachophoresis; perchlorate; polyvinylpyrrolidone; ION CHROMATOGRAPHY; ELECTROKINETIC INJECTION; POSTBLAST RESIDUES; MASS-SPECTROMETRY; INORGANIC ANIONS; IDENTIFICATION; CONTAMINATION; SEPARATIONS; ACIDS; CHIP;
D O I
10.1002/jssc.202200188
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical test procedure for the direct determination of trace levels of perchlorate in drinking water by isotachophoresis combined with capillary zone electrophoresis was developed. A capillary electrophoresis analyzer with column coupling technology, capable of combining capillaries with different internal diameters, was employed in combination with conductivity detection. This combination of the capillary electrophoresis techniques facilitated preconcentration of the trace analytes and elimination of potentially interfering macro-components. To eliminate the influence of weak and moderately strong acids on the migration of perchlorate, acidic leading electrolyte (pH 3.2) in the isotachophoresis step and acidic background electrolyte (pH 3.9) in the zone electrophoresis step were chosen. The addition of polyvinylpyrrolidone into the electrolytes enhanced the resolution of perchlorate from other anions, especially remaining anionic macro-components. The developed method is characterized by good repeatability of migration time (relative standard deviation less than 0.2%) as well as peak area (relative standard deviation less than 5.9%), linearity (R = 0.9996), recoveries (100%-112%), and sample throughput (90 samples/24 h). The limit of quantitation for perchlorate in drinking water was achieved at 12.5 nmol/L (1.25 mu g/L). This approach is more sensitive and more robust than transient isotachophoresis and offers advantages over some more established analytical techniques such as ion chromatography.
引用
收藏
页码:3339 / 3347
页数:10
相关论文
共 50 条
  • [1] Determination of chlorite in drinking water by on-line coupling of capillary isotachophoresis and capillary zone electrophoresis
    Praus, P
    TALANTA, 2004, 62 (05) : 977 - 982
  • [2] Determination of inorganic oxyhalides in drinking water by on-line coupled capillary isotachophoresis -: capillary zone electrophoresis
    Kvasnicka, F
    Janda, V
    Rousová, D
    Manda, J
    Kollerová, L
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2005, 3 (01): : 137 - 145
  • [3] Determination of bromate in drinking water by zone electrophoresis-isotachophoresis on a column-coupling chip with conductivity detection
    Bodor, R
    Kaniansky, D
    Masár, M
    Silleová, K
    Stanislawski, B
    ELECTROPHORESIS, 2002, 23 (20) : 3630 - 3637
  • [4] Determination of Lamotrigine by Isotachophoresis - Capillary Zone Electrophoresis
    Budakova, Lucie
    Brozmanova, Hana
    Kvasnicka, Frantisek
    Grundmann, Milan
    CHEMICKE LISTY, 2009, 103 (02): : 166 - 171
  • [5] Determination of Chlorate and Perchlorate Ions in Drinking Water Using Capillary Electrophoresis
    Sursyakova, Viktoria V.
    Rubaylo, Anatoly, I
    JOURNAL OF SIBERIAN FEDERAL UNIVERSITY-CHEMISTRY, 2018, 11 (03): : 361 - 368
  • [6] Trace determination of perchlorate using electromembrane extraction and capillary electrophoresis with capacitively coupled contactless conductivity detection
    Kiplagat, Isaac K.
    Thi Kieu Oanh Doan
    Kuban, Pavel
    Bocek, Petr
    ELECTROPHORESIS, 2011, 32 (21) : 3008 - 3015
  • [7] Feasibility of using capillary zone electrophoresis with photometric detection for the trace level detection of bromate in drinking water
    Gries, Tammy
    Sitorius, Emily
    Giesecke, Anne
    Schlegel, Vicki
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2008, 25 (11): : 1318 - 1327
  • [8] Determination of bromate ion in drinking water by capillary zone electrophoresis with direct photometric detection
    Takayanagi, Toshio
    Ishida, Makoto
    Mbuna, Julius
    Driouich, Rim
    Motomizu, Shoji
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1128 (1-2) : 298 - 302
  • [9] DETERMINATION OF CHLORIDE, NITRATE, SULFATE, NITRITE, FLUORIDE, AND PHOSPHATE BY ON LINE COUPLED CAPILLARY ISOTACHOPHORESIS-CAPILLARY ZONE ELECTROPHORESIS WITH CONDUCTIVITY DETECTION
    KANIANSKY, D
    ZELENSKY, I
    HYBENOVA, A
    ONUSKA, FI
    ANALYTICAL CHEMISTRY, 1994, 66 (23) : 4258 - 4264
  • [10] Determination of quinine in beverages by online coupling capillary isotachophoresis to capillary zone electrophoresis with UV spectrophotometric detection
    Mikus, Peter
    Marakova, Katarina
    Veizerova, Lucia
    Piest'ansky, Juraj
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (23) : 3392 - 3398