Evaluation of Overall Thermal Transfer Value (OTTV) for commercial buildings constructed with green roof

被引:55
作者
Chan, A. L. S. [1 ]
Chow, T. T. [1 ]
机构
[1] City Univ Hong Kong, Coll Sci & Engn, Div Bldg Sci & Technol, Hong Kong, Hong Kong, Peoples R China
关键词
Overall Thermal Transfer Value (OTTV); Green roof system; EnergyPlus; Correction factors; Building energy simulations; ENERGY PERFORMANCE; SIMULATION; SYSTEM; ATHENS; GARDEN; MODEL; COST;
D O I
10.1016/j.apenergy.2013.02.010
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Overall Thermal Transfer Value (OTTV) is a measure of average heat gain into a building through the building envelope. It is a widely adopted measure in many countries for enhancing energy-efficient building design. In the past decade, there is increasing application of green roof into commercial buildings for enhanced building insulation, leading to reduction in heat gain through the roof area as well as cooling requirement of a building. Since the current OTTV equations and coefficients were originally developed for buildings with traditional bare roof construction, building designers have difficulty to compute the OTTV for building constructed with green roof. The aim of this study is to revise the existing OTTV calculation method and derive a set of correction factors for OTTV evaluation of green roof integrated buildings. An experimental setup of a green roof system with sensors was installed on the rooftop of a commercial building. The measured data were used for validation of a building energy simulation program EnergyPlus incorporated with a green roof model Ecoroof. Four building cases with typical and traditional roof constructions were modeled using the validated computer simulation program. Through a series of parametric computer simulations, a correlation between OTTV and annual heat gain through the roof area was established with that a set of correction factors ranging from 0.03 to 0.99 was developed. Theses correction factors can be used by building designers to compute the OTTV of building constructed with green roof. The details of methodology and findings are reported in this paper. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:10 / 24
页数:15
相关论文
共 52 条
[1]   Developing a one-dimensional heat and mass transfer algorithm for describing the effect of green roofs on the built environment: Comparison with experimental results [J].
Alexandri, Eleftherla ;
Jones, Phil .
BUILDING AND ENVIRONMENT, 2007, 42 (08) :2835-2849
[2]  
[Anonymous], 1991, J ROGER PRESTON PART, VI and II
[3]  
[Anonymous], 1975, ASHRAE STANDARD 90 1
[4]  
[Anonymous], 2011, PRACTICE NOTE FOR AU
[5]  
[Anonymous], 2007, FINAL REPORT
[6]  
[Anonymous], 1979, HANDBOOK ON ENERGY C
[7]  
[Anonymous], 1993, GUIDELINES FOR ENERG
[8]  
[Anonymous], 1989, GUIDELINES FOR ENERG
[9]   Generation of a typical meteorological year for Hong Kong [J].
Chan, ALS ;
Chow, TT ;
Fong, SKF ;
Lin, JZ .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (01) :87-96
[10]   An OTTV-based energy estimation model for commercial buildings in Thailand [J].
Chirarattananon, S ;
Taveekun, J .