Free Breathing Three-Dimensional Gradient Echo-Sequence With Radial Data Sampling (Radial 3D-GRE) Examination of the Pancreas: Comparison With Standard 3D-GRE Volumetric Interpolated Breathhold Examination (VIBE)

被引:35
作者
Bamrungchart, Saraporn [1 ,2 ]
Tantaway, Engy M. [1 ]
Midia, Esin C. [1 ]
Hernandes, Mateus A. [1 ]
Srirattanapong, Saowanee [1 ,3 ]
Dale, Brian M. [4 ]
Semelka, Richard C. [1 ]
机构
[1] Univ N Carolina, Dept Radiol, Chapel Hill, NC 27599 USA
[2] Lerdsin Hosp, Dept Radiol, Bangkok, Thailand
[3] Mahidol Univ, Ramathibodi Hosp, Fac Med, Dept Diagnost & Therapeut Radiol, Bangkok 10400, Thailand
[4] Siemens Med Solut USA Inc, Cary, NC USA
关键词
radial acquisition; three-dimensional gradient echo-sequence; free breathing; abdominal MRI; noncooperative patients; pancreatic imaging; PROJECTION RECONSTRUCTION; DYNAMIC MRI; ACQUISITION; NEOPLASMS;
D O I
10.1002/jmri.24064
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo evaluate the diagnostic performance of free breathing three-dimensional gradient echo-sequence with radial data sampling (radial 3D-GRE) in MR imaging of the normal and diseased pancreas, using standard 3D-GRE for comparison in cooperative patients, and to perform a preliminary assessment in noncooperative patients. Materials and MethodsOne hundred and eight consecutive patients underwent 1.5 Tesla MR imaging of the abdomen that included pre- and postcontrast free breathing radial 3D-GRE. The sequences were evaluated by two radiologists retrospectively, independently, and blindly. The results were compared using Wilcoxon-Mann-Whitney test. Kappa statistics were used to measure the extent of agreement between the reviewers. ResultsThe average scores indicated that the overall images quality of radial 3D-GRE was lower than 3D-GRE-VIBE in both pre- and postcontrast study (P = 0.0172 and 0.0001), however it achieved a rating that approximated good. In all patients, radial 3D-GRE had a mild extent of streak artifact, pulsation, susceptibility, and respiratory artifact. Radial 3D-GRE approximated good results for pancreatic edge sharpness and pancreatic ductal clarity, and did not differ significantly between cooperative and noncooperative patients. Respiratory artifact was worse in cooperative than in noncooperative patients (P = 0.02). Demonstration of pancreatic disease was slightly inferior with radial 3D-VIBE, but quality approximated good. ConclusionFree breathing radial 3D-GRE may be applicable for pancreatic MR imaging in patients who are unable to suspend respiration. J. Magn. Reson. Imaging 2013;38:1572-1577. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1572 / 1577
页数:6
相关论文
共 20 条
[1]  
Altun E, 2010, ABDOMINAL PELVIC MRI
[2]   Water excitation MPRAGE: An alternative sequence for postcontrast imaging of the abdomen in noncooperative patients at 1.5 Tesla and 3.0 Tesla MRI [J].
Altun, Ersan ;
Semelka, Richard C. ;
Dale, Brian M. ;
Elias, Jorge, Jr. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (05) :1146-1154
[3]   Radiologic features of cystic, endocrine and other pancreatic neoplasms [J].
Balci, NC ;
Semelka, RC .
EUROPEAN JOURNAL OF RADIOLOGY, 2001, 38 (02) :113-119
[4]   Suspected pancreatic cancer: Evaluation by dynamic gadolinium-enhanced 3D gradient-echo [J].
Birchard, KR ;
Semelka, RC ;
Hyslop, WB ;
Brown, A ;
Armao, D ;
Firat, Z ;
Vaidean, G .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (03) :700-703
[5]   Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint [J].
Block, Kai Tobias ;
Uecker, Martin ;
Frahm, Jens .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) :1086-1098
[6]   Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient Echo Sequence A Viable Alternative for Contrast-Enhanced Liver Imaging in Patients Unable to Suspend Respiration [J].
Chandarana, Hersh ;
Block, Tobias K. ;
Rosenkrantz, Andrew B. ;
Lim, Ruth P. ;
Kim, Danny ;
Mossa, David J. ;
Babb, James S. ;
Kiefer, Berthold ;
Lee, Vivian S. .
INVESTIGATIVE RADIOLOGY, 2011, 46 (10) :648-653
[7]   A rapid look-up table method for reconstructing MR images from arbitrary K-space trajectories [J].
Dale, B ;
Wendt, M ;
Duerk, JL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (03) :207-217
[8]   CONSISTENT PROJECTION RECONSTRUCTION (CPR) TECHNIQUES FOR MRI [J].
GLOVER, GH ;
NOLL, DC .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (03) :345-351
[9]   Pitfalls in MR cholangiopancreatographic interpretation [J].
Irie, H ;
Honda, H ;
Kuroiwa, T ;
Yoshimitsu, K ;
Aibe, H ;
Shinozaki, K ;
Masuda, K .
RADIOGRAPHICS, 2001, 21 (01) :23-37
[10]   MR coronary vessel wall imaging:: Comparison between radial and spiral k-space sampling [J].
Katoh, M ;
Spuentrup, E ;
Buecker, A ;
Manning, WJ ;
Günther, RW ;
Botnar, RM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (05) :757-762