Spread spectrum sensors for critical fault location on live wire networks

被引:41
作者
Furse, C [1 ]
Smith, P
Lo, C
Chung, YC
Pendayala, P
Nagoti, K
机构
[1] Univ Utah, Dept Elect & Comp Engn, Salt Lake City, UT 84112 USA
[2] LiveWire Test Labs Inc, Salt Lake City, UT USA
[3] Dae Gu Univ, Informat & Commun Engn Dept, Kyungsan 712714, Kyungbuk, South Korea
[4] Qualcore Log, Sunnyvale, CA 94089 USA
关键词
reflectometry; spread spectrum; wiring; fault location; health monitoring; aging;
D O I
10.1002/stc.69
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Aging wiring networks have been identified as an area of critical national and international concern. One of the particularly challenging problems is the location of intermittent faults that cannot be replicated on the ground. This paper describes the application of spread spectrum fault location and wire health monitoring methods whose unique low-interference potential and high-noise immunity enable them to locate faults while networks are active. The analysis and feasibility of this method has been described in previous work, and this paper focuses on evaluation of the accuracy of the method and effects of branched wire networks on the sensor response. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:257 / 267
页数:11
相关论文
共 18 条
[1]  
CHUNG Y, IEEE T EMC
[2]   Frequency-domain reflectometery for on-board testing of aging aircraft wiring [J].
Furse, C ;
Chung, YC ;
Dangol, R ;
Nielsen, M ;
Mabey, G ;
Woodward, R .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2003, 45 (02) :306-315
[3]  
FURSE C, IN PRESS IEEE SENSOR
[4]  
FURSE C, 2001, IEEE SPECTRUM FEB, P35
[5]  
*ILC DAT DEV CORP, 1998, 1533 ILC DAT DEV COR
[6]  
JONES W, 2001, SEQUENCE TIME DOMAIN
[7]   HIGH-SENSITIVITY NARROW-BAND TIME-DOMAIN REFLECTOMETER [J].
MACKAY, NAM ;
PENSTONE, SR .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1974, IM23 (02) :155-158
[8]  
MEDELIUS PJ, 1997, Patent No. 5977773
[9]  
NAGOTI K, 2004, THESIS U UTAH SALT L
[10]  
*NASA, 2000, WIRI INT RES WIRE PI