Scheimpflug Camera Measurement of Anterior and Posterior Corneal Curvature in Eyes With Previous Radial Keratotomy

被引:19
作者
Camellin, Massimo [2 ]
Savini, Giacomo [1 ]
Hoffer, Kenneth J. [3 ,4 ]
Carbonelli, Michele [1 ]
Barboni, Piero [5 ]
机构
[1] GB Bietti Eye Fdn IRCCS, Rome, Italy
[2] SEKAL Rovigo Microsurg, Rovigo, Italy
[3] Univ Calif Los Angeles, Jules Stein Eye Inst, Los Angeles, CA 90024 USA
[4] St Marys Eye Ctr, Santa Monica, CA USA
[5] Studio Oculist dAzeglio, Bologna, Italy
关键词
INTRAOCULAR-LENS POWER; FREQUENCY DIGITAL ULTRASOUND; IN-SITU KERATOMILEUSIS; EXCIMER-LASER SURGERY; REFRACTIVE SURGERY; PHOTOREFRACTIVE KERATECTOMY; EPITHELIAL THICKNESS; KERATOMETRIC INDEX; LASIK; PENTACAM;
D O I
10.3928/1081597X-20120221-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the anterior and posterior corneal curvature in eyes with previous radial keratotomy (RK) to normal unoperated eyes. METHODS: In this retrospective observational case series, 29 eyes from 29 consecutive patients were analyzed and compared to a control group of 71 unoperated eyes. Corneal imaging was obtained by a rotating Scheimpflug camera (Pentacam, Oculus Optikgerate GmbH). Anterior and posterior corneal curvature radii were measured at the 3-mm zone. RESULTS: The mean anterior and posterior corneal radii were 9.54 +/- 0.89 and 8.54 +/- 1.01 mm, respectively, both values being significantly higher than in the control group (7.81 +/- 0.28 and 6.40 +/- 0.24 mm, respectively, P<.0001). The mean anterior-to-posterior corneal curvature ratio was 1.12 +/- 0.07, a value significantly lower than in the control group (1.22 +/- 0.03, P<.0001). Mean corneal flattening was more evident in the posterior (33.44%) than in the anterior (22.15%) corneal curvature. The mean keratometric index, as calculated with the Gullstrand equation for thick lenses, was 1.3319 +/- 0.0026, a value significantly higher than in the control group (1.3281 +/- 0.0011, P<.0001). Linear regression detected a significant and directly proportional relationship between the number of radial incisions and flattening of both corneal surfaces (P<.0001). CONCLUSIONS: After RK, both corneal surfaces flatten but do not deform in parallel as commonly accepted, as shown by the fact that the anterior-to-posterior corneal curvature ratio decreases. This finding invalidates the standard keratometric index and thus has relevant implications for intraocular lens power calculation in RK eyes. [J Refract Surg. 2012;28(4):275-279.] doi:10.3928/1081597X-20120221-03
引用
收藏
页码:275 / 279
页数:5
相关论文
共 37 条
[21]  
Maeda N, 1997, CORNEA, V16, P517
[22]   Formula for determining corneal refractive power [J].
Maloney, Robert K. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02) :211-212
[23]   ON THE CALCULATION OF POWER FROM CURVATURE OF THE CORNEA [J].
OLSEN, T .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1986, 70 (02) :152-154
[24]   Intraocular lens power calculation after incisional and thermal keratorefractive surgery [J].
Packer, M ;
Brown, LK ;
Hoffman, RS ;
Fine, IH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (07) :1430-1434
[25]  
Patel SV, 2007, J REFRACT SURG, V23, P385
[26]   Epithelial Thickness Up to 26 Years After Radial Keratotomy: Three-dimensional Display With Artemis Very High-frequency Digital Ultrasound [J].
Reinstein, Dan Z. ;
Archer, Timothy J. ;
Gobbe, Marine .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (08) :618-624
[27]   Epithelial Thickness Profile Changes Induced by Myopic LASIK as Measured by Artemis Very High-frequency Digital Ultrasound [J].
Reinstein, Dan Z. ;
Srivannaboon, Sabong ;
Gobbe, Marine ;
Archer, Timothy J. ;
Silverman, Ronald H. ;
Sutton, Hugo ;
Coleman, D. Jackson .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (05) :444-450
[28]  
SALZ J, 1981, OPHTHALMOLOGY, V88, P742
[29]   Corneal power measurements with the Pentacam Scheimpflug camera after myopic excimer laser surgery [J].
Savini, Giacomo ;
Barboni, Piero ;
Profazio, Vincenzo ;
Zanini, Maurizio ;
Hoffer, Kenneth J. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (05) :809-813
[30]   Correlation between attempted correction and keratometric refractive index of the cornea after myopic excimer laser surgery [J].
Savini, Giacomo ;
Barboni, Piero ;
Zanini, Maurizio .
JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (05) :461-466