Scheimpflug Camera Measurement of Anterior and Posterior Corneal Curvature in Eyes With Previous Radial Keratotomy

被引:17
|
作者
Camellin, Massimo [2 ]
Savini, Giacomo [1 ]
Hoffer, Kenneth J. [3 ,4 ]
Carbonelli, Michele [1 ]
Barboni, Piero [5 ]
机构
[1] GB Bietti Eye Fdn IRCCS, Rome, Italy
[2] SEKAL Rovigo Microsurg, Rovigo, Italy
[3] Univ Calif Los Angeles, Jules Stein Eye Inst, Los Angeles, CA 90024 USA
[4] St Marys Eye Ctr, Santa Monica, CA USA
[5] Studio Oculist dAzeglio, Bologna, Italy
关键词
INTRAOCULAR-LENS POWER; FREQUENCY DIGITAL ULTRASOUND; IN-SITU KERATOMILEUSIS; EXCIMER-LASER SURGERY; REFRACTIVE SURGERY; PHOTOREFRACTIVE KERATECTOMY; EPITHELIAL THICKNESS; KERATOMETRIC INDEX; LASIK; PENTACAM;
D O I
10.3928/1081597X-20120221-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the anterior and posterior corneal curvature in eyes with previous radial keratotomy (RK) to normal unoperated eyes. METHODS: In this retrospective observational case series, 29 eyes from 29 consecutive patients were analyzed and compared to a control group of 71 unoperated eyes. Corneal imaging was obtained by a rotating Scheimpflug camera (Pentacam, Oculus Optikgerate GmbH). Anterior and posterior corneal curvature radii were measured at the 3-mm zone. RESULTS: The mean anterior and posterior corneal radii were 9.54 +/- 0.89 and 8.54 +/- 1.01 mm, respectively, both values being significantly higher than in the control group (7.81 +/- 0.28 and 6.40 +/- 0.24 mm, respectively, P<.0001). The mean anterior-to-posterior corneal curvature ratio was 1.12 +/- 0.07, a value significantly lower than in the control group (1.22 +/- 0.03, P<.0001). Mean corneal flattening was more evident in the posterior (33.44%) than in the anterior (22.15%) corneal curvature. The mean keratometric index, as calculated with the Gullstrand equation for thick lenses, was 1.3319 +/- 0.0026, a value significantly higher than in the control group (1.3281 +/- 0.0011, P<.0001). Linear regression detected a significant and directly proportional relationship between the number of radial incisions and flattening of both corneal surfaces (P<.0001). CONCLUSIONS: After RK, both corneal surfaces flatten but do not deform in parallel as commonly accepted, as shown by the fact that the anterior-to-posterior corneal curvature ratio decreases. This finding invalidates the standard keratometric index and thus has relevant implications for intraocular lens power calculation in RK eyes. [J Refract Surg. 2012;28(4):275-279.] doi:10.3928/1081597X-20120221-03
引用
收藏
页码:275 / 279
页数:5
相关论文
共 50 条
  • [1] Ratio of Posterior and Anterior Corneal Radii of Curvature in Eyes With Radial Keratotomy
    Shirayama, M.
    Wang, L.
    Koch, D. D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [2] Analysis of anterior and posterior corneal curvature changes using Orbscan technology in radial keratotomy eyes exposed to hypoxia
    McMann, MA
    Parmley, VC
    Brady, SM
    White, LJ
    Raymond, WR
    Mazzoli, RA
    Hansen, EA
    Mader, TH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02): : 289 - 294
  • [3] CORNEAL CURVATURE CHANGES AS A FUNCTION OF RADIAL KERATOTOMY INCISION LENGTH ON HUMAN CADAVER EYES
    WANG, Y
    ELIZONDO, M
    KIANG, E
    MARTIN, D
    RONK, J
    GOOSEY, JD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1295 - 1295
  • [4] Cataract surgery outcomes in eyes with previous radial keratotomy
    Soare, Cristina
    Patel, Darshak S.
    Ionides, Alexander
    EYE, 2022, 36 (09) : 1804 - 1809
  • [5] Outcomes of Phacoemulsification Using Different Size of Clear Corneal Incision in Eyes with Previous Radial Keratotomy
    Zhang, Jing Shang
    Liu, Xue
    Wang, Jin Da
    Xiong, Ying
    Li, Jing
    Li, Xiao Xia
    Zhao, Jing
    You, Qi Sheng
    Huang, Yao
    Tsai, Frank
    Baum, Larry
    Jhanji, Vishal
    Wan, Xiu Hua
    PLoS One, 2016, 11 (12):
  • [6] Cataract surgery outcomes in eyes with previous radial keratotomy
    Cristina Soare
    Darshak S. Patel
    Alexander Ionides
    Eye, 2022, 36 : 1804 - 1809
  • [7] Comparison of a New Swept-Source Anterior Segment Optical Coherence Tomography and a Scheimpflug Camera for Measurement of Corneal Curvature
    Zhang, Ting
    Zhou, Yijing
    Young, Charlotte Aimee
    Chen, Aiming
    Jin, Guangming
    Zheng, Danying
    CORNEA, 2020, 39 (07) : 818 - 822
  • [8] RADIAL KERATOTOMY .3. RELATIONSHIP BETWEEN WOUND GAPE AND CORNEAL CURVATURE IN PRIMATE EYES
    PETROLL, WM
    NEW, K
    SACHDEV, M
    CAVANAGH, HD
    JESTER, JV
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (12) : 3283 - 3291
  • [9] MODIFICATION OF CORNEAL CURVATURE FOLLOWING RADIAL KERATOTOMY IN PRIMATES
    STEEL, D
    JESTER, JV
    SALZ, J
    VILLASENOR, RA
    LEE, JS
    SCHANZLIN, DJ
    SMITH, RE
    OPHTHALMOLOGY, 1981, 88 (08) : 747 - 754
  • [10] Clinical Outcomes of Modified Manual Deep Anterior Lamellar Keratoplasty for Eyes with Previous Radial Keratotomy
    Aiello, Francesco
    Pocobelli, Giulio
    Iovieno, Alfonso
    Komaiha, Chiara
    Nucci, Carlo
    Pocobelli, Augusto
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (17)