Electrocatalytic evaluation of a horseradish peroxidase biosensor based on a novel Bi-Ag bimetallic nanocomposite

被引:6
作者
van der Horst, Charlton [1 ,2 ]
Silwana, Bongiwe [1 ,2 ]
Iwuoha, Emmanuel [1 ]
Somerset, Vernon [2 ]
机构
[1] Univ Western Cape, Dept Chem, SensorLab, ZA-7535 Bellville, South Africa
[2] CSIR, NRE, ZA-7600 Stellenbosch, South Africa
来源
BIOSENSORS 2016 | 2017年 / 27卷
基金
新加坡国家研究基金会;
关键词
Differential pulse voltammetry; Horseradish peroxidase; Hydrogen peroxide; Bismuth-silver nanoparticles; Cyclic voltammetry; HYDROGEN-PEROXIDE; POLYMER; WATER;
D O I
10.1016/j.protcy.2017.04.077
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The present work illustrates the construction and application of bismuth-silver bimetallic nanoparticles (Bi-AgNPs) in biosensor construction for the detection of peroxide (H2O2). The biosensor was constructed by drop-casting of horseradish peroxidase onto the Bi-AgNPs/GCE sensor. Impedance analysis revealed that the R-ct value for the bare GCE obtained was 2.548 x 10(3) Omega and increased to 5.768 x 10(3) Omega for the HRP/Bi-AgNPs/GCE biosensor. This increased value of R-ct indicated hindrance to the electron transfer, providing evidence for the immobilization of insulating HRP on the Bi-AgNPs/GCE surface. The HRP/Bi-AgNPs/GCE biosensor was successfully applied for sensitive detection of H2O2 by differential pulse voltammetry. Well defined peaks were observed with a low linearity range from 0.02 x 10(-6) to 1.0 x 10(-6) M (R-2 = 0.991), with a limit of detection of 0.06 mu M. The results obtained for the HRP/Bi-AgNPs/GCE biosensor compared well within the range of similar biosensors reported.
引用
收藏
页码:179 / 182
页数:4
相关论文
共 22 条
[1]   Chemiluminescence flow biosensor for hydrogen peroxide using DNAzyme immobilized on eggshell membrane as a thermally stable biocatalyst [J].
Chen, Weiwei ;
Li, Baoxin ;
Xu, Chunli ;
Wang, Lei .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (08) :2534-2540
[2]   AMPEROMETRIC SENSORS FOR PEROXIDE, CHOLINE, AND ACETYLCHOLINE BASED ON ELECTRON-TRANSFER BETWEEN HORSERADISH-PEROXIDASE AND A REDOX POLYMER [J].
GARGUILO, MG ;
HUYNH, N ;
PROCTOR, A ;
MICHAEL, AC .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :523-528
[3]   ACCURACY OF DETERMINATION OF HYDROGEN PEROXIDE BY CERATE OXIDIMETRY [J].
HURDIS, EC ;
ROMEYN, H .
ANALYTICAL CHEMISTRY, 1954, 26 (02) :320-325
[4]   A hydrogen peroxide biosensor based on direct electrochemistry of hemoglobin incorporated in PEO-PPO-PEO triblock copolymer film [J].
Jia, Nengqin ;
Lian, Qiong ;
Wang, Zhiyong ;
Shen, Hebai .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (01) :230-234
[5]   OXO[5,10,15,20-TETRA(4-PYRIDYL)PORPHYRINATO]TITANIUM(IV) - AN ULTRA-HIGH SENSITIVITY SPECTROPHOTOMETRIC REAGENT FOR HYDROGEN-PEROXIDE [J].
MATSUBARA, C ;
KAWAMOTO, N ;
TAKAMURA, K .
ANALYST, 1992, 117 (11) :1781-1784
[6]   Reversible, fluorescence-based optical sensor for hydrogen peroxide [J].
Mills, Andrew ;
Tommons, Cheryl ;
Bailey, Raymond T. ;
Tedford, M. Catriona ;
Crilly, Peter J. .
ANALYST, 2007, 132 (06) :566-571
[7]   A Novel Hydrogen Peroxide Biosensor Based on Adsorption of Horseradish Peroxidase onto a Nanobiomaterial Composite Modified Glassy Carbon Electrode [J].
Moyo, Mambo ;
Okonkwo, Jonathan O. ;
Agyei, Nana M. .
ELECTROANALYSIS, 2013, 25 (08) :1946-1954
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF HYDROGEN-PEROXIDE WITH PEROXYOXALATE CHEMILUMINESCENCE DETECTION [J].
NAKASHIMA, K ;
WADA, M ;
KURODA, N ;
AKIYAMA, S ;
IMAI, K .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (10) :2111-2126
[9]  
Rad AS, 2012, INT J ELECTROCHEM SC, V7, P2623
[10]   Biosensors as useful tools for environmental analysis and monitoring [J].
Rodriguez-Mozaz, Sara ;
Lopez de Alda, Maria J. ;
Barcelo, Damia .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (04) :1025-1041