Application of microwave tomography to investigation the wet gas-solids flow hydrodynamic characteristics in a fluidized bed

被引:23
作者
Che, H. Q. [1 ,2 ]
Wang, H. G. [1 ,2 ]
Ye, J. M. [1 ]
Yang, W. Q. [3 ]
Wu, Z. P. [3 ]
机构
[1] Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Univ Manchester, Sch Elect & Elect Engn, Manchester M13 9PL, Lancs, England
基金
中国国家自然科学基金;
关键词
Fluidized bed; Coating; Microwave tomography; Defluidization; Moisture content; ELECTRICAL CAPACITANCE TOMOGRAPHY; DEFLUIDIZATION;
D O I
10.1016/j.ces.2018.01.032
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Fluidized beds are widely used in pharmaceutical industry for particles coating and granulation. Due to the complex gas solids flow process, it is extremely desirable that a real time monitoring and control system is used in the process in order to enable a bubbling stable fluidization and reduce the chance of defluidization due to agglomeration with high moisture contents particles. The microwave tomography (MWT) technology has been developed for more than twenty years and was mainly applied in medical sectors. MWT has a wide range of frequency (1-2.5 GHz) and can be used to measure materials with high permittivity and conductivity. Therefore, it is a good choice for the monitoring of fluidized bed coating and granulation processes. In this paper, a MWT system with 16 antennas was designed and applied for the monitoring of wetting and coating processes in a lab-scale fluidized bed with top-spray and bottom-spray system. The hydrodynamics characteristics of wet gas-solids flow with different moisture content were investigated by MWT technology. This is the first time that MWT was applied in a real dynamics gas-solids fluidized bed. Experiment result shows that the MWT is available for the online monitoring of the gas solids flow with different moisture content. Different flow regimes were revealed based on the MWT images combined with pressure signals. The results indicate that the MWT provides valuable information to identify the defluidization in the fluidized bed process with high moisture contents materials. It is evident that microwave tomography has clear advantages over single point based measurement technology for process fault diagnose. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:20 / 32
页数:13
相关论文
共 33 条
[1]  
Abdullah MZ, 2012, WOODHEAD PUBL FOOD S, P64
[2]  
[Anonymous], MICROWAVE CANC DIAGN
[3]  
[Anonymous], FLOW MEAS I IN PRESS
[4]   Application of electrical capacitance tomography to the fluidized bed drying of pharmaceutical granule [J].
Chaplin, G ;
Pugsley, T .
CHEMICAL ENGINEERING SCIENCE, 2005, 60 (24) :7022-7033
[5]   Monitoring and control of coating and granulation processes in fluidized beds - A review [J].
da Silva, Carlos Alexandre M. ;
Butzge, Jose Junior ;
Nitz, Marcella ;
Taranto, Osvaldir P. .
ADVANCED POWDER TECHNOLOGY, 2014, 25 (01) :195-210
[6]   Electrostatics in gas-solid fluidized beds: A review [J].
Fotovat, Farzam ;
Bi, Xiaotao T. ;
Grace, John R. .
CHEMICAL ENGINEERING SCIENCE, 2017, 173 :303-334
[7]   Microwave imaging - Complex permittivity reconstruction with a Levenberg-Marquardt method [J].
Franchois, A ;
Pichot, C .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1997, 45 (02) :203-215
[8]   Investigation of gas-solids flow characteristics in a conical fluidized bed dryer by pressure fluctuation and electrical capacitance tomography [J].
Ge, Ruihuan ;
Ye, Jiamin ;
Wang, Haigang ;
Yang, Wuqiang .
DRYING TECHNOLOGY, 2016, 34 (11) :1359-1372
[9]  
Heinrich S., 2015, Advances in Chemical Engineering, P83, DOI [DOI 10.1016/BS.ACHE.2015.10.012, 10.1016/bs.ache.2015.10.012]
[10]   Effect of particle size distribution on agglomeration/defluidization during fluidized bed combustion [J].
Lin, Chiou-Liang ;
Peng, Tzu-Huan ;
Wang, Wei-Jen .
POWDER TECHNOLOGY, 2011, 207 (1-3) :290-295