A glass/PDMS electrophoresis microchip embedded with molecular imprinting SPE monolith for contactless conductivity detection

被引:29
|
作者
Zhai, Haiyun [1 ]
Li, Jiangmei [1 ]
Chen, Zuanguang [2 ]
Su, Zihao [1 ]
Liu, Zhenping [1 ]
Yu, Xiao [1 ]
机构
[1] Guangdong Pharmaceut Univ, Coll Pharm, Guangzhou 510006, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Sch Pharmaceut Sci, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Microchip; Capillary electrophoresis; Contactless conductivity detection; Molecularly imprinted solid-phase extraction; Auramine O; SOLID-PHASE EXTRACTION; INTEGRATED MICROFLUIDIC DEVICE; IONIZATION MASS-SPECTROMETRY; CAPILLARY-ELECTROPHORESIS; LIQUID-CHROMATOGRAPHY; DEGRADATION-PRODUCTS; BASIC DRUGS; CHIP; POLYMERS; PRECONCENTRATION;
D O I
10.1016/j.microc.2014.01.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple glass/PDMS microfluidic chip for on-line sample pretreatment and contactless conductivity detection, which consisted of a 0.17 mm-thick glass cover and a PDMS substrate embedded with an SPE monolithic column, was presented in this paper. Using this integrated microchip system, sample extraction, injection, separation and detection were automatically performed in sequence. A sample of auramine O was concentrated by molecularly imprinted SPE (MISPE), eluted to sample reservoir, and injected by electromigration into separation channel for electrophoresis separation and contactless conductivity detection, with the calculated detection limit (S/N = 3) being 2.5 mu g mL(-1). The monolithic column was utilized to quantitatively extract auramine 0, yielding an on-line enrichment factor of about 12. The microchip system is reliable and applicable to the analysis of auramine Din food sample. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:223 / 228
页数:6
相关论文
共 50 条
  • [11] Capillary and microchip electrophoresis with contactless conductivity detection for analysis of foodstuffs and beverages
    Tuma, Petr
    Opekar, Frantisek
    Dlouhy, Pavel
    FOOD CHEMISTRY, 2022, 375
  • [12] Contactless conductivity detector for microchip capillary electrophoresis
    Pumera, M
    Wang, J
    Opekar, F
    Jelínek, I
    Feldman, J
    Löwe, H
    Hardt, S
    ANALYTICAL CHEMISTRY, 2002, 74 (09) : 1968 - 1971
  • [13] Detection of human immunoglobulin in microchip and conventional capillary electrophoresis with contactless conductivity measurements
    Abad-Villar, EM
    Tanyanyiwa, J
    Fernández-Abedul, MT
    Costa-García, A
    Hauser, PC
    ANALYTICAL CHEMISTRY, 2004, 76 (05) : 1282 - 1288
  • [14] A microchip electrophoresis system with integrated in-plane electrodes for contactless conductivity detection
    Lichtenberg, J
    de Rooij, NF
    Verpoorte, E
    ELECTROPHORESIS, 2002, 23 (21) : 3769 - 3780
  • [15] Determination of heavy metal ions by microchip capillary electrophoresis coupled with contactless conductivity detection
    Liu, Benyan
    Zhang, Yi
    Mayer, Dirk
    Krause, Hans-Joachim
    Jin, Qinghui
    Zhao, Jianlong
    Offenhaeusser, Andreas
    Xu, Yuansen
    ELECTROPHORESIS, 2012, 33 (08) : 1247 - 1250
  • [16] High-voltage capacitively coupled contactless conductivity detection for microchip capillary electrophoresis
    Tanyanyiwa, J
    Hauser, PC
    ANALYTICAL CHEMISTRY, 2002, 74 (24) : 6378 - 6382
  • [17] Determination of glyphosate and AMPA on polyester-toner electrophoresis microchip with contactless conductivity detection
    da Silva, Eduardo R.
    Segato, Thiago P.
    Coltro, Wendell K. T.
    Lima, Renato S.
    Carrilho, Emanuel
    Mazo, Luiz H.
    ELECTROPHORESIS, 2013, 34 (14) : 2107 - 2111
  • [18] Simulation research on contactless conductivity detection of capillary electrophoresis microchip based on wavelet packets
    Institute of Microelectronics, Department of Electronics Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
    不详
    Xitong Fangzhen Xuebao / Journal of System Simulation, 2008, 20 (19): : 5291 - 5296
  • [19] Design of Movable Contactless Conductivity Detector for Microchip Capillary Electrophoresis
    Zhang, Hai-feng
    Liui, Xiao-wei
    Peng, Zhi-cheng
    Wang, Xi-lian
    Wang, Wei
    Chen, Yu-feng
    2009 4TH IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1 AND 2, 2009, : 190 - +
  • [20] Direct detection of histamine in fish flesh using microchip electrophoresis with capacitively coupled contactless conductivity detection
    Thredgold, Leigh D.
    Ellis, Amanda V.
    Lenehan, Claire E.
    ANALYTICAL METHODS, 2015, 7 (05) : 1802 - 1808