摘要
We describe here an optimization study of the sample preparation conditions for sensitive detection of peptides by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Among many factors in the conditions, we varied the percent acetonitrile in the peptide solution, the percent acetonitrile in the matrix solution and the -cyano-4-hydroxycinnamic acid (CHCA) concentration in the matrix solution. CHCA was chosen because it is the most frequently used matrix for analyzing peptides. The well-established dried-droplet method was employed for sample deposition. The examined range of the concentration of CHCA was from 0.01 to 10mg/ml, and the MeCN content of the solvent for matrix/analyte was 10% to 50%. The indicator for the detection sensitivity was the S/N ratio of the peaks of peptides used. Highly increased sensitivity (100- to 1000-fold) was observed for the optimal CHCA concentration of 0.1mg/ml in 20% MeCN/0.1% aq. trifluoroacetic acid (TFA), as compared with the conventional concentration (10mg/ml) in 50% MeCN/0.1% aq. TFA. For example, the limit of detection of human ACTH 18-39 was 10amol/well for the optimal condition but 10fmol/well for the conventional condition. The optimal condition (0.1mg/ml CHCA in 20% MeCN/0.1% aq. TFA) was verified with five model peptides and provided significant improvement in sensitivity (by two to three orders of magnitude) compared with the conventional conditions. Optimizing the CHCA concentration and solvent composition significantly improved the detection sensitivity in the analysis of peptides by MALDI-MS. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:1217 / 1223
页数:7
相关论文
共 50 条
  • [41] Toward Prediction: Using Chemometrics for the Optimization of Sample Preparation in MALDI-TOF MS of Synthetic Polymers
    Brandt, Heike
    Ehmann, Thomas
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (19) : 8169 - 8175
  • [42] Imaging Method by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry (MALDI-MS) for Tissue or Tumor: A Mini Review
    Wu, Jiawen
    Rong, Ze
    Xiao, Peng
    Li, Yuanzhe
    [J]. PROCESSES, 2022, 10 (02)
  • [43] Coupling Strong Anion-Exchange Monolithic Capillary with MALDI-TOF MS for Sensitive Detection of Phosphopeptides in Protein Digest
    Dong, Mingming
    Wu, Minghuo
    Wang, Fangjun
    Qin, Hongqiang
    Han, Guanghui
    Gong, Jing
    Wu, Ren'an
    Ye, Mingliang
    Liu, Zhen
    Zou, Hanfa
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (07) : 2907 - 2915
  • [44] Rapid LC-MS method for the detection of common fragrances in personal care products without sample preparation
    Famiglini, Giorgio
    Termopoli, Veronica
    Palma, Pierangela
    Capriotti, Fabiana
    Cappiello, Achille
    [J]. ELECTROPHORESIS, 2014, 35 (09) : 1339 - 1345
  • [45] MALDI-MS detection of noncovalent interactions of single stranded DNA with Escherichia coli single-stranded DNA-binding protein
    Chen, Fan
    Maedler, Stefanie
    Weidmann, Simon
    Zenobi, Renato
    [J]. JOURNAL OF MASS SPECTROMETRY, 2012, 47 (05): : 560 - 566
  • [46] Conductive carbon tape as a sample platform for microwave-based MALDI MS detection of proteins and phosphoproteins
    Juang, Yu-Min
    Chen, Chao-Jung
    Lai, Chien-Chen
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (04) : 1219 - 1229
  • [47] MALDI-MS analysis of sialylated N-glycan linkage isomers using solid-phase two step derivatization method
    Li, Henghui
    Gao, Wenjie
    Feng, Xiaojun
    Liu, Bi-Feng
    Liu, Xin
    [J]. ANALYTICA CHIMICA ACTA, 2016, 924 : 77 - 85
  • [48] Multisensor Imaging-From Sample Preparation to Integrated Multimodal Interpretation of LA-ICPMS and MALDI MS Imaging Data
    Holzlechner, Matthias
    Bonta, Maximilian
    Lohninger, Hans
    Limbeck, Andreas
    Marchetti-Deschmann, Martina
    [J]. ANALYTICAL CHEMISTRY, 2018, 90 (15) : 8831 - 8837
  • [49] Developing front-end devices for improved sample preparation in MS-based proteome analysis
    Doucette, Alan A.
    Nickerson, Jessica L.
    [J]. JOURNAL OF MASS SPECTROMETRY, 2020, 55 (03):
  • [50] Chemical derivatization with a polycyclic aromatic hydrocarbon for highly sensitive detection of N-linked glycans using MALDI-TOF MS
    Tong, Wei
    Han, Huanhuan
    Song, Zifeng
    Ma, Cheng
    Pan, Yiting
    Zhang, Yangjun
    Qin, Weijie
    Qian, Xiaohong
    [J]. ANALYTICAL METHODS, 2012, 4 (11) : 3531 - 3535