Scaphoid Overstuffing: The Effects of the Dimensions of Scaphoid Reconstruction on Scapholunate Alignment

被引:33
作者
Capito, Anthony E. [1 ]
Higgins, James P. [1 ]
机构
[1] MedStar Union Mem Hosp, Curtis Natl Hand Ctr, Baltimore, MD USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2013年 / 38A卷 / 12期
关键词
Scapholunate dissociation; scaphoid nonunion; medial femoral trochlea; humpback deformity; dorsal intercalated segmental instability (DISI); MEDIAL FEMORAL CONDYLE; BIOMECHANICAL EVALUATION; LIGAMENTOUS STABILIZERS; PROXIMAL POLE; CADAVER MODEL; WRIST; BONE; DISSOCIATION; CAPSULODESIS; INSTABILITY;
D O I
10.1016/j.jhsa.2013.09.035
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Osteochondral replacement of the proximal scaphoid has been reported using a vascularized flap from the medial femoral trochlea. A concern with this technique is the loss of stability of the scapholunate relationship with resection of the scaphoid proximal pole. Overexpansion of the scaphoid dimensions (overstuffing) during scaphoid reconstruction with the osteochondral flap may play a role in maintaining scapholunate alignment. Our purpose was to determine if overstuffing the scaphoid can correct rotatory carpal instability in a cadaveric model studied radiographically. Methods The radiolunate angle and scapholunate interval were measured for 5 fresh cadaver wrists. We completely incised the scapholunate interosseous ligament and performed an osteotomy to excise the proximal third of the scaphoid to simulate a proximal pole deficiency nonunion and create a dorsal intercalated segmental instability deformity. Radiographic measurements were repeated. The proximal pole of the scaphoid was replaced with its original piece of bone; radiographic measurements were repeated without scapholunate ligament repair. The osteotomy site was overstuffed with a 4-mm sawbone spacer without scapholunate ligament repair, and radiographs were obtained. Results Sectioning of scapholunate ligaments and proximal pole excision successfully created carpal instability demonstrated by abnormal radiolunate angles. Without ligament repair, proximal pole replacement did not restore normal radiolunate angles. Expansion of the scaphoid dimensions corrected radiolunate angles on lateral unloaded radiographs and improved scapholunate intervals on clenched fist radiographs. These findings were statistically significant compared with the unexpanded (replaced) scaphoid. Conclusions These findings suggest that scaphoid reconstruction that results in expansion of the scaphoid's normal dimensions will restore carpal alignment without scapholunate ligament reconstruction. Clinical relevance Osteochondral reconstruction of difficult proximal pole nonunions may not require any preservation or reconstruction of scapholunate integrity if the reconstruction expands the normal dimensions of the native scaphoid. Scapholunate interval and carpal alignment may be restored by scaphoid overstuffing. The effects on increased contact pressure and range of motion require further investigation. (J Hand Surg Am. 2013;38(12):2419-2425. Copyright (C) 2013 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:2419 / 2425
页数:7
相关论文
共 27 条
  • [1] Acute scaphoid fractures
    Adams, Julie E.
    Steinmann, Scott P.
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 2007, 38 (02) : 229 - +
  • [2] Vascularized Medial Femoral Trochlea Osteocartilaginous Flap Reconstruction of Proximal Pole Scaphoid Nonunions
    Buerger, Heinz K.
    Windhofer, Christian
    Gaggl, Alexander J.
    Higgins, James P.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (04): : 690 - 700
  • [3] SILICONE-RUBBER CARPAL IMPLANTS - A STUDY OF THE INCIDENCE OF LATE OSSEOUS COMPLICATIONS
    CARTER, PR
    BENTON, LJ
    DYSERT, PA
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1986, 11A (05): : 639 - 644
  • [4] GarciaElias M, 1997, HAND CLIN, V13, P151
  • [5] Haussmann P, 1983, Handchir Mikrochir Plast Chir, V15, P182
  • [6] Long-term results after silicone prosthesis replacement of the proximal pole of the scaphoid bone in advanced scaphoid nonunion
    Haussmann, P
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2002, 27B (05) : 417 - 423
  • [7] Subchondral bone and cartilage disease - A rediscovered functional unit
    Imhof, H
    Sulzbacher, I
    Grampp, S
    Czerny, C
    Youssefzadeh, S
    Kainberger, F
    [J]. INVESTIGATIVE RADIOLOGY, 2000, 35 (10) : 581 - 588
  • [8] The Limits of Medial Femoral Condyle Corticoperiosteal Flaps
    Iorio, Matthew L.
    Masden, Derek L.
    Higgins, James P.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (10): : 1592 - 1596
  • [9] KAUER JMG, 1986, CLIN ORTHOP RELAT R, P16
  • [10] DEMONSTRATION OF THE SCAPHOLUNATE SPACE WITH RADIOGRAPHY
    KINDYNIS, P
    RESNICK, D
    KANG, HS
    HALLER, J
    SARTORIS, DJ
    [J]. RADIOLOGY, 1990, 175 (01) : 278 - 280