An Open-Source Ultrasound Software for Diagnosis of Fistula Maturation

被引:7
作者
Belmont, Barry [1 ]
Park, Dae Woo [2 ]
Weitzel, William F. [3 ,4 ]
Shih, Albert J. [1 ,2 ]
机构
[1] Univ Michigan, Biomed Engn, Ann Arbor, MI 48109 USA
[2] Natl Canc Ctr, Innovat Med Engn & Technol, 323 Ilsan Ro, Goyang Si 10408, Gyeonggi Do, South Korea
[3] Vet Affairs Ann Arbor Hlth Syst, Ann Arbor, MI USA
[4] Internal Med, Ann Arbor, MI USA
关键词
autogenous arteriovenous fistulas; distensibility; flow gradient; DIAMETER; FAILURE; GRAFTS;
D O I
10.1097/MAT.0000000000000590
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vascular access is essential for hemodialysis patients. The mature native arteriovenous fistula has been the preferred vascular access for hemodialysis, because it has greater longevity than synthetic grafts. However, once surgically created, fistulas often fail to develop (mature) into viable points of vascular access, requiring surgical or radiologic interventions before their use. Because maturation depends on vascular mechanics (e.g., distensibility and wall shear), we developed open-source ultrasound software to investigate these metrics clinically. We demonstrated in a single patient the ability of the software for consistent measurements from various locations within a cardiac cycle and between different cardiac cycles. We further assessed the ability of the software to identify changes in distensibility of a patient's fistula from 1 to 6 weeks postoperation. The routine frame rates of clinical machines demonstrated high fidelity tracking within cardiac cycles (coefficient of variation [CV] = 2.4% +/- 0.011) and between cardiac cycles (CV = 2.4% +/- 0.004). The distensibility of the patient's fistula from 1 to 6 weeks postoperation increased from 4% to 7% in the arterial inflow and from 3% to 4% in the postarterial anastomotic segment (PAAS). In contrast, the distensibility of the outflow vein decreased from 4% to 2%. These results corroborate that in addition to diameter changes, the mechanical properties of the vascular segments changed during fistula maturation. This demonstrates that our software-based approach may allow ultrasound-based mechanical measurements to become more accessible for wider clinical research.
引用
收藏
页码:70 / 76
页数:7
相关论文
共 19 条
[1]   Impact of secondary procedures in autogenous arteriovenous fistula maturation and maintenance - Discussion [J].
Lumsden, AB ;
Berman, SS ;
Gloviczki, P .
JOURNAL OF VASCULAR SURGERY, 2001, 34 (05) :870-871
[2]   Vascular access use and outcomes: an international perspective from the dialysis outcomes and practice patterns study [J].
Ethier, Jean ;
Mendelssohn, David C. ;
Elder, Stacey J. ;
Hasegawa, Takeshi ;
Akizawa, Tadao ;
Akiba, Takashi ;
Canaud, Bernard J. ;
Pisoni, Ronald L. .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2008, 23 (10) :3219-3226
[3]   Vascular access survival and incidence of revisions: A comparison of prosthetic grafts, simple autogenous fistulas, and venous transposition fistulas from the United States Renal Data System Dialysis Morbidity and Mortality Study [J].
Gibson, KD ;
Gillen, DL ;
Caps, MT ;
Kohler, TR ;
Sherrard, DJ ;
Stehman-Breen, CO .
JOURNAL OF VASCULAR SURGERY, 2001, 34 (04) :694-700
[4]   Prospective validation of an algorithm to maximize native arteriovenous fistulae for chronic hemodialysis access [J].
Huber, TS ;
Ozaki, CK ;
Flynn, TC ;
Lee, WA ;
Berceli, SA ;
Hirneise, CM ;
Carlton, LM ;
Carter, JW ;
Ross, EA ;
Seeger, JM .
JOURNAL OF VASCULAR SURGERY, 2002, 36 (03) :452-458
[5]   Influence of arterial elasticity and vessel dilatation on arteriovenous fistula maturation: a prospective cohort study [J].
Kheda, Mufaddal F. ;
Brenner, Lacie E. ;
Patel, Mittal J. ;
Wynn, James J. ;
White, John J. ;
Prisant, L. Michael ;
Jones, Steven A. ;
Paulson, William D. .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2010, 25 (02) :525-531
[6]   Vein diameter is the major predictor of fistula maturation [J].
Lauvao, Lannery S. ;
Ihnat, Daniel M. ;
Goshima, Kaoru R. ;
Chavez, Leann ;
Gruessner, Angelika C. ;
Mills, Joseph L., Sr. .
JOURNAL OF VASCULAR SURGERY, 2009, 49 (06) :1499-1504
[7]   KDOQI clinical practice guidelines and clinical practice recommendations for diabetes and chronic kidney disease [J].
Levin, Adeera ;
Rocco, Michael .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2007, 49 (02) :S10-S179
[8]   Cumulative Patency of Contemporary Fistulas versus Grafts (2000-2010) [J].
Lok, Charmaine E. ;
Sontrop, Jessica M. ;
Tomlinson, George ;
Rajan, Dheeraj ;
Cattral, Mark ;
Oreopoulos, George ;
Harris, Jeremy ;
Moist, Louise .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2013, 8 (05) :810-818
[9]  
Lucas BD., 1981, ITERATIVE IMAGE REGI, DOI DOI 10.5555/1623264.1623280
[10]   Prediction of wrist arteriovenous fistula maturation with preoperative vein mapping with ultrasonography [J].
Mendes, RR ;
Farber, MA ;
Marston, WA ;
Dinwiddie, LC ;
Keagy, BA ;
Burnham, SJ .
JOURNAL OF VASCULAR SURGERY, 2002, 36 (03) :460-463