High temperature superconducting current lead test facility with heat pipe intercepts

被引:4
作者
Blumenfeld, PE [1 ]
Prenger, C [1 ]
Roth, EW [1 ]
Stewart, JA [1 ]
机构
[1] Univ Calif Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
D O I
10.1109/77.783351
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A high temperature superconducting (HTS) current lead test facility using heat pipe thermal intercepts is under development Pt the Superconductivity Technology Center at Los Alamos National Laboratory, The facility can be configured for tests at currents up to 1000 A Mechanical cryocoolers provide refrigeration to the leads, Electrical isolation is maintained by intercepting thermal energy from the leads through cryogenic heat pipes, HTS lead warm end temperature is variable from 65 K to over 90 K by controlling heat pipe evaporator temperature. Cold end temperature is variable up to 30 K. Performance predictions in terms of heat pipe evaporator temperature as a function of lead current are presented for the initial facility configuration, which supports testing up to 200 A. Measurements are to include temperature and voltage gradient in the conventional and HTS lead sections, temperature distribution and heat transfer rate in the heat pipes, as well as optimum and off-optimum performance of the conventional lead sections.
引用
收藏
页码:527 / 530
页数:4