Interventional MR imaging:: percutaneous abdominal and skeletal biopsies and drainages of the abdomen

被引:57
作者
Adam, G [1 ]
Bücker, A [1 ]
Nolte-Ernsting, C [1 ]
Tacke, J [1 ]
Günther, RW [1 ]
机构
[1] Univ Technol Aachen, Dept Diagnost Radiol, D-52074 Aachen, Germany
关键词
MR imaging; interventional; biopsies; drainages; percutaneous procedures; biopsy tools;
D O I
10.1007/s003300050873
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Since the introduction of open magnets and short-bore closed magnets, and the availability of fast imaging sequences, MR imaging has become a tool for guidance and control of percutaneous nonvascular and vascular procedures. In general, percutaneous biopsies or drainages require no specific hardware or software modifications. For lesion localization and control of the needle track, simple fast imaging sequences such as fast T1-weighted gradient-echo techniques or fast single-shot T2-weighted spin-echo sequences are sufficient and can be applied depending on the best tissue-to-lesion contrast. Typical scan times range from 1 to 3 s. Different types of biopsy needles are commercially available, allowing sampling of sufficient amounts of tissue. For drainage procedures non-ferromagnetic materials, such as nitinol wires, should be preferred to minimize image distortion by metallic artifacts. Indications for percutaneous biopsies include subdiaphragmatic liver lesions, lesions poorly visible on ultrasound or contrast-enhanced computed tomography, and lesions of the bone marrow characterized by an unspecific bone marrow edema. For percutaneous drainages, subdiaphragmatic lesions appear to be a good indication. With some experience the procedure time is not longer than that under CT or US guidance.
引用
收藏
页码:1471 / 1478
页数:8
相关论文
共 44 条
  • [1] Interventional magnetic resonance - Initial clinical experience with a 1.5-tesla magnetic resonance system combined with c-arm fluoroscopy
    Adam, G
    Neuerburg, J
    Bucker, A
    Glowinski, A
    Vorwerk, D
    Stargardt, A
    VanVaals, JJ
    Gunther, RW
    [J]. INVESTIGATIVE RADIOLOGY, 1997, 32 (04) : 191 - 197
  • [2] Interventional MR tomography: equipment concepts
    Adam, G
    Bucker, A
    Glowinski, A
    Nolte-Ernsting, C
    Neuerburg, J
    Gunther, RW
    [J]. RADIOLOGE, 1998, 38 (03): : 168 - 172
  • [3] Stent placement under real-time MR control:: First experience in an animal model.
    Bücker, A
    Neuerburg, JM
    Adam, G
    Schürmann, K
    Rasche, V
    van Vaals, JJ
    Molgaard-Nielsen, A
    Günther, RW
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (06): : 655 - 657
  • [4] Real-time MRI with radial scanning technique for control of angiographic interventions.
    Bucker, A
    Adam, G
    Neuerburg, JM
    Glowinski, A
    Nolte-Ernsting, CCA
    Hunter, D
    Grosskortenhaus, S
    Leenen, M
    Rasche, V
    Proksa, R
    van Vaals, JJ
    Hurtak, W
    Gunther, RW
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (05): : 542 - 546
  • [5] MR-guided biopsies with an ultrafast high-resolution T-2-weighted turbo spin echo sequence ''LoLo'': First clinical results
    Bucker, A
    Adam, G
    Neuerburg, JM
    Glowinski, A
    vanVaals, JJ
    Gunther, RW
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (05): : 491 - 495
  • [6] Debatin JF, 1998, MED RAD DIA IMG, P269
  • [7] HEAD AND NECK LESIONS - MR-GUIDED ASPIRATION BIOPSY
    DUCKWILER, G
    LUFKIN, RB
    TERESI, L
    SPICKLER, E
    DION, J
    VINUELA, F
    BENTSON, J
    HANAFEE, W
    [J]. RADIOLOGY, 1989, 170 (02) : 519 - 522
  • [8] Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T
    Duerk, JL
    Lewin, JS
    Wendt, M
    Petersilge, C
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01): : 203 - 208
  • [9] MR FLUOROSCOPY - INITIAL CLINICAL-STUDIES
    FARZANEH, F
    RIEDERER, SJ
    LEE, JN
    TASCIYAN, T
    WRIGHT, RC
    SPRITZER, CE
    [J]. RADIOLOGY, 1989, 171 (02) : 545 - 549
  • [10] Technique of MR-guided core biopsy of abdominal masses using an open low-field scanner: Feasibility and first clinical results
    Frahm, C
    Gehl, HB
    Weiss, HD
    Rossberg, WA
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1996, 164 (01): : 62 - 67