Comparison of pulmonary artery dimensions in swine obtained from catheter angiography, multi-slice computed tomography, 3D-rotational angiography and phase-contrast magnetic resonance angiography

被引:6
作者
Pewowaruk, Ryan [1 ]
Mendrisova, Klarka [2 ]
Larrain, Carolina [3 ]
Francois, Christopher J. [3 ,4 ]
Roldan-Alzate, Alejandro [1 ,2 ,4 ]
Lamers, Luke [3 ,5 ]
机构
[1] Univ Wisconsin, Biomed Engn, Madison, WI 53792 USA
[2] Univ Wisconsin, Mech Engn, Madison, WI 53792 USA
[3] Univ Wisconsin, H6 516D Clin Sci Ctr, Sch Med & Publ Hlth, 600 Highland Ave, Madison, WI 53792 USA
[4] Univ Wisconsin, Radiol, Madison, WI 53792 USA
[5] Univ Wisconsin, Div Cardiol, Pediat, Madison, WI 53792 USA
关键词
Congenital heart disease; Pulmonary artery imaging; Pulmonary artery stenosis; CONGENITAL HEART-DISEASE; GADOLINIUM DEPOSITION; MR-ANGIOGRAPHY; CARDIOVASCULAR MR; STENOSIS; ADULTS; IMPLANTATION; PERFUSION;
D O I
10.1007/s10554-020-02043-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Accurate pulmonary artery (PA) imaging is necessary for management of patients with complex congenital heart disease (CHD). The ability of newer imaging modalities such as 3D rotational angiography (3DRA) or phase-contrast magnetic resonance angiography (PC-MRA) to measure PA diameters has not been compared to established angiography techniques. Measurements of PA diameters (including PA stenosis and PA stents) from 3DRA and non-contrast-enhanced PC-MRA were compared to 2D catheter angiography (CA) and multi-slice computed tomography (MSCT) in a swine CHD model (n = 18). For all PA segments 3DRA had excellent agreement with CA and MSCT (ICC = 0.94[0.91-0.95] and 0.92[0.89-0.94]). 3DRA PA stenosis measures were similar to CA and MSCT and 3DRA was on average within 5% of 10.8 +/- 1.3 mm PA stent diameters from CA and MSCT. For compliant PA segments, 3DRA was on average 3-12% less than CA (p < 0.05) and MSCT (p < 0.01) for 6-14 mm vessels. PC-MRA could not reliably visualize stents and distal PA vessels and only identified 34% of all assigned measurement sites. For measured PA segments, PC-MRA had good agreement to CA and MSCT (ICC = 0.87[0.77-0.92] and 0.83[0.72-0.90]) but PC-MRA overestimated stenosis diameters and underestimated compliant PA diameters. Excellent CA-MSCT PA diameter agreement (ICC = 0.95[0.93-0.96]) confirmed previous data in CHD patients. There was little bias in PA measurements between 3DRA, CA and MSCT in stenotic and stented PAs but 3DRA underestimates measurements of compliant PA regions. Accurate PC-MRA imaging was limited to unstented proximal PA anatomy.
引用
收藏
页码:743 / 753
页数:11
相关论文
共 31 条
[1]   Consequences of an early catheter-based intervention on pulmonary artery growth and right ventricular myocardial function in a pig model of pulmonary artery stenosis [J].
Bates, Melissa L. ;
Anagnostopoulos, Petros, V ;
Nygard, Cole ;
Torgeson, Jenna ;
Reichert, Jamie ;
Galambos, Csaba ;
Eldridge, Marlowe W. ;
Lamers, Luke J. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (01) :78-87
[2]   CONTROLLING THE FALSE DISCOVERY RATE - A PRACTICAL AND POWERFUL APPROACH TO MULTIPLE TESTING [J].
BENJAMINI, Y ;
HOCHBERG, Y .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1995, 57 (01) :289-300
[3]  
Choe Yeon Hyeon, 1998, Journal of Korean Medical Science, V13, P597
[4]   Gadolinium Deposition in the Brain: Current Updates [J].
Choi, Jin Woo ;
Moon, Won-Jin .
KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (01) :134-147
[5]   Cardiovascular MR and CT in congenital heart disease [J].
Crean, Andrew .
HEART, 2007, 93 (12) :1637-1647
[6]   DynaCT during EVAR - A Comparison with Multidetector CT [J].
Eide, K. R. ;
Odegard, A. ;
Myhre, H. O. ;
Lydersen, S. ;
Hatlinghus, S. ;
Haraldseth, O. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 37 (01) :23-30
[7]  
ELZENGA NJ, 1990, J THORAC CARDIOV SUR, V100, P416
[8]   4D cardiovascular magnetic resonance velocity mapping of alterations of right heart flow patterns and main pulmonary artery hemodynamics in tetralogy of Fallot [J].
Francois, Christopher J. ;
Srinivasan, Shardha ;
Schiebler, Mark L. ;
Reeder, Scott B. ;
Niespodzany, Eric ;
Landgraf, Benjamin R. ;
Wieben, Oliver ;
Frydrychowicz, Alex .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
[9]   Renal Arteries: Isotropic, High-Spatial-Resolution, Unenhanced MR Angiography with Three-dimensional Radial Phase Contrast [J].
Francois, Christopher J. ;
Lum, Darren P. ;
Johnson, Kevin M. ;
Landgraf, Benjamin R. ;
Bley, Thorsten A. ;
Reeder, Scott B. ;
Schiebler, Mark L. ;
Grist, Thomas M. ;
Wieben, Oliver .
RADIOLOGY, 2011, 258 (01) :254-260
[10]   Fontan operation in five hundred consecutive patients: Factors influencing early and late outcome [J].
Gentles, TL ;
Mayer, JE ;
Gauvreau, K ;
Newburger, JW ;
Lock, JE ;
Kupferschmid, JP ;
Burnett, J ;
Jonas, RA ;
Castaneda, AR ;
Wernovsky, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 114 (03) :376-391