A case study of novel X-ray Optics for FEL sources

被引:6
|
作者
Rehanek, J. [1 ]
Schaefers, F. [1 ]
Loechel, H. [1 ]
Firsov, A. [1 ]
Gruenert, J. [2 ]
Freund, W. [2 ]
Ozkan, C. [2 ]
Molodtsov, S. [2 ]
Erko, A. [1 ]
机构
[1] HZB BESSY II, Inst Nanometre Opt & Technol, Albert Einstein Str 15, D-12489 Berlin, Germany
[2] European XFEL GmbH, D-22761 Hamburg, Germany
来源
11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012) | 2013年 / 425卷
关键词
D O I
10.1088/1742-6596/425/5/052013
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We suggest optical schemes for the European X-ray Free Electron Laser facility (XFEL.EU) in Hamburg: a single element X-ray spectrometer on the basis of a reflection zone plate (RZP) for single-shot diagnostics; and a two-element soft X-ray spectrometer on the basis of two RZPs to carry out Resonant Inelastic X-ray Scattering (RIXS) experiments. With this setup, a full map of the sample spectrum is obtainable in a single measurement. The main advantage of using zone plates is the possibility to enable dispersion and focusing in one step. Moreover, highest possible X-ray transmission is achieved by using the minimum number of optical elements. Taking into account the European XFEL beam parameters, our simulations, concerning the RIXS experiment, produced very promising results, reaching an energy resolution (E/Delta E) of up to 30,000 at photon energy of 1 keV. When applied as a single shot spectrometer the energy resolution for RZP is of the same order of magnitude.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Multilayer optics for novel sources In X-ray analytics
    Kleine, A.
    Hasse, B.
    Graf, J.
    Heidorn, U.
    Kroth, S.
    Hertlein, F.
    Wiesmann, J.
    Michaelsen, C.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2011, 67 : C255 - C256
  • [2] State-of-the-art thin film X-ray optics for synchrotrons and FEL sources
    Hertlein, Frank
    Wiesmann, Joerg
    Michaelsen, Carsten
    Stoermer, Michael
    Seifert, Andreas
    DAMAGE TO VUV, EUV, AND X-RAY OPTICS, 2007, 6586
  • [3] State-of-the-art thin film X-ray optics for conventional synchrotrons and FEL sources
    Wiesmann, Joerg
    Michaelsen, Carsten
    Hertlein, Frank
    Stoermer, Michael
    Seifert, Andreas
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 774 - +
  • [4] Optics for coherent x-ray sources
    Pantell, RH
    Feinstein, J
    Cremer, JT
    Piestrup, MA
    Beguiristain, HR
    Gary, CK
    OPTICS FOR FOURTH-GENERATION X-RAY SOURCES, 2001, 4500 : 123 - 132
  • [5] FICTITIOUS SOURCES IN X-RAY OPTICS
    BABUSHKIN, FA
    OPTIKA I SPEKTROSKOPIYA, 1977, 43 (06): : 1172 - 1173
  • [6] PARAMETRIC STUDY OF AN X-RAY FEL
    TRAVISH, G
    FAWLEY, WM
    KIM, KJ
    NUHN, HD
    PELLEGRINI, C
    WINICK, H
    XIE, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 358 (1-3): : 60 - 63
  • [7] X-RAY OPTICS Highly efficient nanoscale X-ray sources
    Rolles, Daniel
    NATURE PHOTONICS, 2018, 12 (02) : 62 - 63
  • [8] X-RAY OPTICS FOR PLASMA POINT SOURCES
    ZOREV, NN
    X-RAY INSTRUMENTATION IN MEDICINE AND BIOLOGY, PLASMA PHYSICS, ASTROPHYSICS, AND SYNCHROTRON RADIATION, 1989, 1140 : 214 - 219
  • [9] X-RAY OPTICS FOR LABORATORY SOURCES.
    Kunz, M.
    Reifler, H.
    Bottger, G.
    Miletich, R.
    Friedrich, A.
    Pattison, P.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1999, 55 : 229 - 229
  • [10] Compound refractive lenses as prefocusing optics for X-ray FEL radiation
    Heimann, Philip
    MacDonald, Michael
    Nagler, Bob
    Lee, Hae Ja
    Galtier, Eric
    Arnold, Brice
    Xing, Zhou
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 425 - 429