NEONATAL SEIZURE DETECTION USING BLIND ADAPTIVE FUSION

被引:0
作者
Li, Huaying [1 ]
Jeremic, Aleksandar [1 ]
机构
[1] McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON, Canada
来源
BIOSIGNALS 2011 | 2011年
关键词
Seizure detection; Distributed detection; Neonatal seizures; Biomedical signal processing; EEG;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Seizure is the result of excessive electrical discharges of neurons, which usually develops synchronously and happens suddenly in the central nervous system. Clinically, it is difficult for physician to identify neonatal seizures visually, while EEG seizures can be recognized by the trained experts. Usually, in NICUs, EEG monitoring systems are used in stead of the expensive on-site supervision. However, it is a waste of time to review an overnight recording, which motivates the researchers to develop automated seizure detection algorithms. Although, there are few detection algorithms existed in the literature, it is difficult to evaluate these mathematical model based algorithm since their performances vary significantly on different data sets. By extending our previous results on multichannel information fusion, we propose a distributed detection system consisting of the existing detectors and a fusion center to detect the seizure activities in the newborn EEG. The advantage of this proposed technique is that it does not require any priori knowledge of the hypotheses and the detector performances, which are often unknown in real applications. Therefore, this proposed technique has the potential to improve the performances of the existing neonatal seizure detectors. In this paper, we first review two newborn EEG models, one of which is used to generate neonatal EEG signals. The synthetic data is used later for testing purpose. We also review three existing algorithms on this topic and implement them to work as the local detectors of the system. Then, we introduce the fusion algorithms applied in the fusion center for two different scenarios: large sample size and small sample size. We finally provide some numerical results to show the applicability, effectiveness, and the adaptability of the blind algorithms in the seizure detection problem. We also provide the testing results obtained using the synthetic to show the improvement of the detection system.
引用
收藏
页码:365 / 371
页数:7
相关论文
共 8 条
  • [1] [Anonymous], 2001, NEUROLOGY NEWBORN
  • [2] A computer-aided detection of EEG seizures in infants: A singular-spectrum approach and performance comparison
    Celka, P
    Colditz, P
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (05) : 455 - 462
  • [3] Automatic seizure detection in the newborn: methods and initial evaluation
    Gotman, J
    Flanagan, D
    Zhang, J
    Rosenblatt, B
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 103 (03): : 356 - 362
  • [4] DETECTION OF NEONATAL SEIZURES THROUGH COMPUTERIZED EEG ANALYSIS
    LIU, A
    HAHN, JS
    HELDT, GP
    COEN, RW
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1992, 82 (01): : 30 - 37
  • [5] Liu B., 2007, IEEE INT C AC SPEECH, V2
  • [6] Blind adaptive decision fusion for distributed detection
    Mirjalily, G
    Luo, ZQ
    Davidson, TN
    Bossé, É
    [J]. IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2003, 39 (01) : 34 - 52
  • [7] A nonstationary model of newborn EEG
    Rankine, Luke
    Stevenson, Nathan
    Mesbah, Mostefa
    Boashash, Boualem
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (01) : 19 - 28
  • [8] Varshney PK, 1986, IEEE T AERO ELEC SYS, P98